Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 24 for “"XCAT"”.
-
Development and application of enhanced, high-resolution physiological features in XCAT phantoms for use in virtual clinical trials
… focus is primarily an advanced model known as XCAT. These additions include healthy and progressive-disease anatomy and physiology, micron-level–resolution coronary artery lesions, and an array of pathologies. In particular, we focus on the physiology needed for CT perfusion studies, dynamic …
-
Development of an eXtended Modular ANthropomorphic (XMAN) phantom for Imaging and Treatment Optimization in Radiotherapy
… clinical trials.The 4D-extended cardiac-torso (XCAT) phantom is a digital phantom that simulates diverse human anatomies (e.g., genders, heights, tumor sizes etc.) with cardiac and respiratory motions, and it has been widely used in medical imaging and radiotherapy research. Although being …
-
Volumetric Cine Imaging for On-board Target Localization in Radiation Therapy
… diameter lesion in a computerized patient model (XCAT) with various anatomical and respiratory changes from planning 4D CT to on-board volume. The estimation accuracy was evaluated by the volume percent difference (VPD)/center-of-mass-shift (COMS) between lesions in the estimated and …
-
Dynamic Magnetic Resonance Imaging
… the method on the extended cardiac-torso (XCAT) human body phantom with real life parameter selections. The reconstructions are sharp, accurate and fast without any ringing artifacts caused by the conventional methods.
-
In-silico Modeling, Optimization, and Harmonization of Photon-Counting Detector Computed Tomography
… for task-generic image quality assessment, an XCAT model with bronchitis and emphysema for COPD biomarker extraction, and an XCAT with liver lesions for lesion detectability analysis.</p><p>For the PCD-CT optimization, CdTe-, CZT-, and Si-based PCD-CT scanners were modeled using an in-silico …
-
Optimization of Image Guided Radiation Therapy for Lung Cancer Using Limited-angle Projections
… simulated using the extended cardiac torso (XCAT) digital phantom, the phase-matched DTS technique localizes the 3D target position with an localization error of 1.07 mm (± 0.57 mm) (average ± standard deviation (S.D.)). Similarly, for the total 60 scenarios evaluated using the computerized …
-
On-board Image Augmentation Using Prior Image and Deep Learning for Image-guided Radiation Therapy
… was evaluated using extended-cardiac-torso (XCAT) phantom, physical CatPhan phantom and brain patient data. Results were compared with both TV and edge-preserving TV (EPTV) methods which are commonly used for limited projection CBCT reconstruction. Relative error was used to calculate image …
-
Reconstruction 3D de structures vasculaires par coloriage voxélique à partir d'angiographie biplan
… du simulateur de mouvement cardiorespiratoire XCAT ainsi que sur des données cliniques du CHU de Sainte-Justine. Les résultats obtenus sont encourageants et laissent entrevoir une potentielle utilisation lors d’interventions cliniques.
-
Σύγκριση ακτινοθεραπευτικών τεχνικών για παιδιατρικούς όγκους εγκεφάλου: εκτίμηση του κινδύνου πρόκλησης ακτινογενούς καρκίνου
… χρησιμοποιώντας ψηφιακά ομοιώματα XCAT ηλικίας 5 και 10 ετών. Η αξιολόγηση αναπτύχθηκε σε τρεις άξονες: τη φυσική δοσιμετρία, την έκθεση των οργάνων και τη ραδιοβιολογική ιεράρχηση των πλάνων μέσω του προσδιορισμού του κινδύνου δευτεροπαθούς καρκινογένεσης. Η ραδιοβιολογική ανάλυση …
-
Quantification of Respiratory Motion in Positron Emission Tomography for Precise Radiation Treatment of Lung Cancer
… the effects of respiratory motion. First, a 4D XCAT digital phantom was used to quantify respiratory motion and its effects on lesion displacement. A CTN physical phantom and 3D-printed irregularly shaped lesion were imaged to determine the accuracy of the PET EDGE automated segmentation …
-
Development of Five-dimensional Magnetic Resonance Imaging (5D-MRI) for Radiation Therapy
… technique was tested on a digital human phantom (XCAT) and a liver tumor patient. 5D-MRI images were qualitatively evaluated for image contrast versatility, and quantitatively evaluated for image quality and motion accuracy. For the latter, motion trajectories of the liver tumor in the …
-
Development and validation of a personalizable model of the hepatic arterial tree and particle transport
… hepatic artery segmentations taken from the XCAT phantom. To verify the distributions created through microsphere infusion simulation, a characterization of the three-dimensional clustering of glass microspheres in tissue was necessary. However, traditional methods to find microsphere …
-
4D Image Reconstruction with Dual Respiratory and Cardiac Motion Correction for Cardiac PET
… Carlo simulated 4D cardiac PET data using the 4D XCAT phantom and accurate models of the scanner design parameters and performance characteristics and clinical patient data were used to evaluate all different methods. Data-driven gating method was shown to provide robust gating results in high …
-
On-Board Imaging of Respiratory Motion: Investigation of Markerless and Self-Sorted Four-Dimensional Cone-Beam CT (4D-CBCT)
… may be encountered in the clinic. A 4D digital XCAT phantom was used to generate an array of respiratory and anatomical variables that affect the performance of the technique. The respiratory variables studied included: inspiration to expiration ratio, respiratory cycle length, diaphragmatic …
-
Towards Physiological-based Respiratory Motion Modeling: Improvement on 4D Image Quality and Feature-based Deformable Image Registration
… using the 4D digital eXtended Cardiac Torso (XCAT) phantom. Performance of the sorting methods was evaluated in terms of “tumor” volume precision and accuracy as measured by the 4D images, and also the accuracy of AIP of the 4D images.</p><p>The second part of the work is on the development of …
-
Development of Computational Imaging Pipelines to Advance Virtual PET Imaging Trials
… images. Finally, PAD’s successful application to XCAT-derived activity maps further demonstrated its compatibility with digital phantom-based anatomical priors. In conclusion, this dissertation advances virtual PET imaging across multiple levels of realism and control. FAST-PET provides an …
-
Correlated Polarity Noise Reduction: Development, Analysis, and Application of a Novel Noise Reduction Paradigm
… paradigm. In application to multi-detector CT, XCAT simulations showed that CPNR can be used to reduce noise variance by 40% with minimal blurring of anatomical structures under a filtered back-projection reconstruction paradigm. When an apodization filter was applied, only 33% noise variance …
-
Cardio-respiratory motion compensation for radiation dose reduction in X-ray guided cardiac interventions
… X-ray sequences generated from realistic XCAT computational phantoms with cardio-respiratory motion were first investigated. The simulated motion included the beating heart and respiratory motion. We simulated 56 different patients (32 male and 24 female) and 112 sequences (2 sequences per …
-
Optimization of thermal dose delivery in magnetic nanoparticle hyperthermia, using novel simulation tools
… thermotherapy based on the anthropomorphic XCAT phantom. In both cases optimization of magnetic hyperthermia treatment planning was carried out by computing nanoparticle concentration fields that yielded homogenous temperature and thermal dose distributions in the region of interest. In Part …
Page 1 of 2