Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 12 of 12 for “"XCOM"”.

  1. Studies of Light Element X-Ray Fundamental Parameters Used in PIXE Analysis

    … 4–6% discrepancy was attributed to the use of XCOM[10] MACs but this was reduced to 0.5–2.5% using FFAST[33] MACs. Additional measurements, performed on silicate micro-probe standards, were analyzed using the same comparative approach. A light element efficiency-constant discrepancy of 7–9% was …

    guelph Repository record for Studies of Light Element X-Ray Fundamental Parameters Used in PIXE Analysis (opens in a new tab)

  2. An Experimental re-evaluation of Photon Mass Attenuation Coefficients

    … of Standards and Technology (NIST) database - XCOM. Investigations of the deviation and surrounding references showed XCOM being at most accurate to 5 \% relative uncertainty.

    sask Repository record for An Experimental re-evaluation of Photon Mass Attenuation Coefficients (opens in a new tab)

  3. New Insights into the Landing Phase of Reactive Stepping: Predictors of Control, Muscle Recruitment, Movement Restraints and Two-Step Responses

    … During two-steps, peak AP extrapolated COM (xCOM) displacement after FC was larger in the second vs. the first step with asymmetrical loading, yet the first step resulted in greater ML xCOM displacement vs. the second step, regardless of loading. Interestingly, first step width was narrower …

    waterloo Repository record for New Insights into the Landing Phase of Reactive Stepping: Predictors of Control, Muscle Recruitment, Movement Restraints and Two-Step Responses (opens in a new tab)

  4. Physical and neurophysiological factors influencing dynamic balance

    … were to apply the extrapolated Centre of Mass (XCoM) method and other relevant variables (centre of pressure, CoP; Centre of Mass, CoM; shear forces, Fh; kinetic energy, KE; momentum, P; and angular impulse, AI) to investigate sport related activities such as hopping and jumping. Many studies …

    liverpool-jm Repository record for Physical and neurophysiological factors influencing dynamic balance (opens in a new tab) Download PDF for Physical and neurophysiological factors influencing dynamic balance (opens in a new tab)

  5. Kompozitní materiály se zvýšeným koeficientem lineárního zeslabení ionizujícího záření

    … zeslabení kompozitů byly vypočteny programem XCOM pro energie fotonů 662 keV a 1253 keV. Experimentálně bylo měřeno zeslabení intenzity gama záření zdrojů 137Cs a 60Co. Z experimentálních dat byly stanoveny lineární koeficienty zeslabení a polotloušťky připravených materiálů. Přídavkem plniv …

    brno-tech Repository record for Kompozitní materiály se zvýšeným koeficientem lineárního zeslabení ionizujícího záření (opens in a new tab)

  6. Emulating the Mars APXS with Accelerator-Based PIXE

    … mass attenuation coefficient databases, XCOM and FFAST, was addressed. Deviations of light element (sodium, magnesium, aluminum) concentrations previously seen in the APXS were also seen in the accelerator-based PIXE measurements. These deviations arise from the rock structure’s violation …

    guelph Repository record for Emulating the Mars APXS with Accelerator-Based PIXE (opens in a new tab)

  7. Biomechanical aspects of postural balance strategy in dynamic sport activities

    … particularly for the extrapolated CoM (XCoM) in kicking. Our results justified the use of some model reductions for specific needs, saving measurement effort whilst limiting the error of tracking (X)CoM trajectories in the context of whole-body balance investigation. The second study of …

    liverpool-jm Repository record for Biomechanical aspects of postural balance strategy in dynamic sport activities (opens in a new tab) Download PDF for Biomechanical aspects of postural balance strategy in dynamic sport activities (opens in a new tab)

  8. Tomografia de dupla energia aplicada à caracterização de materiais : metodologia para determinação do número atômico e densidade

    … do modelo, seguido por testes com dados do NIST XCom e experimentos práticos com um tomógrafo de transmissão de raios gama, utilizando fontes de amerício (59,5 keV) e césio (662 keV), além de um microtomógrafo de raios X operando em duas tensões distintas. O desempenho do modelo foi comparado com …

    brazil-ufpe Repository record for Tomografia de dupla energia aplicada à caracterização de materiais : metodologia para determinação do número atômico e densidade (opens in a new tab)

  9. The Effects of Varying Surface Translation Acceleration and Velocity on Compensatory Forward Stepping Responses

    … (AP) extrapolated centre of mass displacement (xCOM), and minimum AP extrapolated margin of stability (xMOS) were extracted from the kinematic data. Trial specific pre-perturbation values of underfoot weight distribution, AP centre of pressure (COP) location, ankle co-contraction index (CCI), AP …

    waterloo Repository record for The Effects of Varying Surface Translation Acceleration and Velocity on Compensatory Forward Stepping Responses (opens in a new tab)

  10. Desenvolvimento de método analítico para determinação de Mg, Ti e Cl em catalisadores ziegler-natta por WDXRF

    … por espectroscopia de fluorescência de raios Xcom dispersão em comprimento de onda (WDXRF) foi avaliado. Três famílias decatalisadores com distintos teores de Mg, Ti e Cl foram utilizados. Para fins de comparação,os analitos foram também determinados por métodos clássicos, a saber, Mg …

    brazil-ufrgs Repository record for Desenvolvimento de método analítico para determinação de Mg, Ti e Cl em catalisadores ziegler-natta por WDXRF (opens in a new tab)

  11. Development of a Virtual Reality-based Balance Training System for Community-Dwelling Older Adults

    … It shows the extrapolated centre of mass (XCOM) relative to the predicted limits of stability (PLOS) of older adults. Feasibility testing indicated a correlation between perceived exergame difficulty and balance intensity scores. POSZ will standardize exercise prescription, dose evaluation, …

    auckland-ms Repository record for Development of a Virtual Reality-based Balance Training System for Community-Dwelling Older Adults (opens in a new tab)

  12. Marges de stabilité avant et après suppression de la douleur chez les personnes gonarthrosiques : Étude de l’impact sur la mécanique de la marche

    … de masse (CoM) et le centre de masse extrapolé (XCoM) ont été calculés pour estimer la marge de stabilité (Hof et al., 2007) pour différents instants du cycle de marche (ToeOff, HeelStrike, minimal) dans les directions médio-latérale (ML) et antéropostérieure (AP). RESULTATS : 90% des …

    ets-quebec Download PDF for Marges de stabilité avant et après suppression de la douleur chez les personnes gonarthrosiques : Étude de l’impact sur la mécanique de la marche (opens in a new tab)