Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 40 for “"Xmax"”

  1. Extracting a less model dependent cosmic ray composition from Xmax distributions

    … measures the depth of shower maximum (Xmax [max subscript]) of ultra high energy cosmic rays, an observable which is sensitive to the mass of the cosmic ray, and often analysed in mass composition studies. At ultra high energies, the results of mass composition studies depend strongly …

    adelaide Repository record for Extracting a less model dependent cosmic ray composition from Xmax distributions (opens in a new tab)

  2. Reconstruction of Xmax and Energy from 3 -- 100 PeV using 5 Years of Data From IceTop and IceCube and its Applications

    … to reconstruct the maximum atmospheric depth (Xmax) and a decision tree to reconstruct the energy for an extensive air shower that is detected by the IceCube Neutrino Observatory. The resolution of our models are about 41.6 $\rm{g/cm^2}$ for Xmax and 5.64\% for log10(E/GeV). Each of these is …

    ohiolink Repository record for Reconstruction of Xmax and Energy from 3 -- 100 PeV using 5 Years of Data From IceTop and IceCube and its Applications (opens in a new tab)

  3. Estimation of the composition of cosmic rays using the radio signal

    … de fluorescence via la mesure de la variable Xmax avec un cycle utile de 14%. Xmax est la profondeur d'atmosphère traversée à laquelle le nombre de particules secondaires atteint sa valeur maximale. Cette observable est fortement corrélée à la masse du rayon cosmique qui a initié la gerbe. Un …

    star-france Repository record for Estimation of the composition of cosmic rays using the radio signal (opens in a new tab)

  4. Ultra-high-energy cosmic particle identification

    … where the number of particles is the greatest (Xmax), which is a measure of the mass of the particle. The method reveals that at the very highest energies, the average mass of the cosmic particles increases with energy. The accurate Xmax measurement using the water detectors is a good step in …

    radboud Repository record for Ultra-high-energy cosmic particle identification (opens in a new tab)

  5. Search for gamma-rays in the EeV sky at the Pierre Auger Observatory using universality

    … profondeur atmosphérique du maximum de la gerbe (Xmax) et un nombre plus faible de muons. Ces deux observables peuvent être mesurées à l’Observatoire Pierre Auger, qui combine, dans un instrument hybride, un détecteur de fluorescence (FD) et un réseau au sol de détecteurs de particules (SD). Dans …

    star-france Repository record for Search for gamma-rays in the EeV sky at the Pierre Auger Observatory using universality (opens in a new tab)

  6. Temporal Dynamics in Spatial Random Field Theory: A Methodological Advance in fMRI Data Analysis

    … random field model with the test statistic Xmax to enhance neural signal detection in fMRI data. Simulations assessed its performance under varying conditions, including amplitude (ξ), signal scale (σ0), spatial location (s0), temporal decay (σρ), and i multiple time points, demonstrating …

    northern-colorado-masters Repository record for Temporal Dynamics in Spatial Random Field Theory: A Methodological Advance in fMRI Data Analysis (opens in a new tab)

  7. Reference Night Aerosol Systematics at the Pierre Auger Observatory

    … energy, E, and the depth of shower maximum, Xmax. The Pierre Auger Observatory uses two centrally located laser facilities to measure the vertical aerosol optical depth (VAOD) every hour, as aerosol distributions can change rapidly with wind conditions. Historically, it has been assumed that …

    adelaide Repository record for Reference Night Aerosol Systematics at the Pierre Auger Observatory (opens in a new tab)

  8. FORWARD HEATING IN WIND-DRIVEN FLAMES

    … The location of maximum pulsation frequency, xmax, for each burner/wind configuration was also obtained using the VITA technique. Further study indicates that xmax can be well estimated using mean flame properties.

    maryland Repository record for FORWARD HEATING IN WIND-DRIVEN FLAMES (opens in a new tab)

  9. Estudo sobre a convivência com crianças e a esperança de idosos

    … children was 38.39 points (DP=5.95, xmin=27.00, xmax=48.00) and the group living with children was 43.39 (DP=4.45, xmin=31.00, xmax=48.00). This difference was significant (U=81.000, p=0.010). Therefore, the hopefulness of the group living with children was higher than in the group not living …

    brazil-ufscar Repository record for Estudo sobre a convivência com crianças e a esperança de idosos (opens in a new tab)

  10. Disentangling atmospheric cascades started by gamma rays from cosmic rays with CORSIKA

    … ajuste más importantes son el m_aximo de lluvia (Xmax), el ancho de la lluvia FWHM, el parámetro de asimetría, el número máximo de partículas Nmax y el comienzo de lluvia XStart. Existen diferentes experimentos utilizando tanques Cherenkov de agua y detectores de fluorescencia que pueden medir …

    pucp-peru-2 Repository record for Disentangling atmospheric cascades started by gamma rays from cosmic rays with CORSIKA (opens in a new tab)

  11. Characterisation of biocatalyst production within an integrated biorefinery context

    … in relation to maximum biomass concentration (Xmax), yield of biomass on substrate (YX/S) and CV2025 ω-TAm specific activity of 3.7, 1.9 and 2.2-fold, respectively, were shown in the MBR compared to conventional shake flask system, also representing a 31-fold volumetric reduction. Optimisation …

    ucl Repository record for Characterisation of biocatalyst production within an integrated biorefinery context (opens in a new tab)

  12. Geology, mineral equilibria, sulfur, rubidium-strontium and lead isotopes and intrusion chemistry of the McDame tungsten skarn prospect, north central British Columbia

    … garnet skarn was stable to Tmax = 555°C and Xmax = 0.14; garnet-bearing quartz skarn formed below Tmax = 475°C and Xmax = 0.08; feldspar-bearing magnetite skarn formed above Tmin = 430°C and Xmin = 0.06; and massive pyrrhOtite skarn altered previously formed skarns at lower T and XCO₂. …

    ubc Repository record for Geology, mineral equilibria, sulfur, rubidium-strontium and lead isotopes and intrusion chemistry of the McDame tungsten skarn prospect, north central British Columbia (opens in a new tab)

  13. Extensive air shower asymmetry and cosmic ray mass composition with the upgraded Pierre Auger Observatory

    … to improve upon the technique of reconstructing Xmax from the slope parameters of lateral distribution functions in simulations.

    adelaide Repository record for Extensive air shower asymmetry and cosmic ray mass composition with the upgraded Pierre Auger Observatory (opens in a new tab)

  14. Études des solutions solides de type M(1-x)M'xXO4 homéotypes du quartz-alpha et cristallogenèse d’un matériau bi-fonctionnel GaAsO4 à propriétés piézoélectriques et optiques non linéaires

    … ont été obtenus par voie hydrothermale avec xmax=0.23. La synthèse hydrothermale in-situ par spectroscopie d'absorption des rayons X a permis de mettre en évidence le rôle essentiel des cations Ga3+ lors de la nucléation et la cristallisation de la phase mixte Ga1-xFexPO4 de structure …

    star-france Repository record for Études des solutions solides de type M(1-x)M'xXO4 homéotypes du quartz-alpha et cristallogenèse d’un matériau bi-fonctionnel GaAsO4 à propriétés piézoélectriques et optiques non linéaires (opens in a new tab)

  15. Measurement of the Cosmic Ray Composition with Air Showers Detected by the AMIGA Extension at the Pierre Auger Observatory

    … und Daten bei etwas anderen Energien. Indem wir Xmax-Messungen von Auger als Schätzer der mittleren logarithmischen Masse in Daten verwenden finden wir, dass der Myonanteil in Simulationen um 38% bis 53%, abhängig vom hadronischen Wechselwirkungsmodell, erhöht werden müsste um mit den …

    karlsruhe-diss Repository record for Measurement of the Cosmic Ray Composition with Air Showers Detected by the AMIGA Extension at the Pierre Auger Observatory (opens in a new tab)

  16. The chemistry of some heterocyclic analogues of triphenylmethane dyes

    … Hammett substituent constant. Observed Xmax(x) values for disubstituted compounds are in good agreement with the values calculated on the basis of additivity of substituent effects. The spectral changes of the x-band arising from ortho- substitution are consistent with the relief of …

    cent-lancashire Repository record for The chemistry of some heterocyclic analogues of triphenylmethane dyes (opens in a new tab)

  17. Estudio experimental del Sistema de la Corriente de Bransfield (Antártida)

    … temporal del ancho (W); la velocidad máxima (V xmax); y la posición de la velocidad máxima, en la dirección perpendicular al canal, (ymax), de la corriente experimental. Los experimentos en cuenca cerrada muestran una corriente con un ancho de 2Rd y un ymax=1Rd, siendo Rd el radio interno de …

    ulpgc Repository record for Estudio experimental del Sistema de la Corriente de Bransfield (Antártida) (opens in a new tab)

  18. Numerisk prissättning av exotiska optioner

    … time interval [0; T] and the space interval [0; xmax] into n and m subintervals, respectively. Examination of the selected Greeks show that Asian options are less sensitive to volatility than lookback and barrier options are. Furthermore, it is concluded that the Crank-Nicolson method is superior …

    chalmers Repository record for Numerisk prissättning av exotiska optioner (opens in a new tab)

  19. Composition studies based on the muon content of air showers measured by underground muon detectors

    … measurements of the depth of the shower maximum Xmax. The study is based on an extended UMD data set comprising data collected in 2018–2021 (Phase 1), together with data recorded in 2023–2024 (Phase 2) following a large-scale upgrade of the detector system, including improved front-end …

    karlsruhe-diss Repository record for Composition studies based on the muon content of air showers measured by underground muon detectors (opens in a new tab)

  20. Growth optimization of Synechococcus sp. PCC7002 in laboratory photobioreactors

    … NaNO₃, FeCl₃, and KH₂PO₄ to achieve highest Xmax were determined to be 23.5 mM, 0.028 mM, and 0.72 mM respectively. The optimal concentrations to achieve highest µmax were 5.88 mM, 0.007 mM, and 0.18 mM respectively. Another factorial experiment regarding the effects of temperature and light …

    ubc Repository record for Growth optimization of Synechococcus sp. PCC7002 in laboratory photobioreactors (opens in a new tab)

Page 1 of 2