Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 4 of 4 for “"YARR"”.

  1. Rapid Synchronization Recovery from Single Event Effects in the Large Hadron Collider

    … mechanism between the RD53 and the YARR DAQ must be improved. A new synchronization system is developed and compared with the original in term of performance and hardware resource utilization. The final product shows enormous benefits in performance, reducing blocks lost to nearly 1% …

    washington Repository record for Rapid Synchronization Recovery from Single Event Effects in the Large Hadron Collider (opens in a new tab)

  2. FPGA Development of an Emulator of the RD53A Prototype Chip and its Integration with Various Readout Systems

    … developed for the coming upgrade. These include YARR [8], RCE [9], and FELIX [10]. The necessary background, the current state of the emulator, and the work done on it regarding the listed readout systems are discussed in this thesis.

    washington Repository record for FPGA Development of an Emulator of the RD53A Prototype Chip and its Integration with Various Readout Systems (opens in a new tab)

  3. The Colonial Logics of Exceptionalism: Imperial Feminism in an American and Canadian Case Study

    This thesis explores the political rhetoric of Western exceptionalism in both the United States and Canada through two contemporary case studies. The first case study explores the American occupation of Afghanistan and rhetoric that painted this occupation as a mission of liberation for Afghan …

    carleton Repository record for The Colonial Logics of Exceptionalism: Imperial Feminism in an American and Canadian Case Study (opens in a new tab)

  4. The relationship of brachial pulse wave measurements to the performance of cross country runners

    The cardiovascular condition of five members of the University of B.C. cross country team was checked weekly with the Cameron Heartometer. Heartograph measures taken twenty-four hours before competition were compared to the coach's subjective appraisal of the athlete's performance to see if …

    ubc Repository record for The relationship of brachial pulse wave measurements to the performance of cross country runners (opens in a new tab) Download PDF for The relationship of brachial pulse wave measurements to the performance of cross country runners (opens in a new tab)