Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 116 for “"Z-Scan"”.

  1. Z-SCAN STUDIES ON ZNSE, ZNS AND GAP

    … and indirect-band-gap semiconductor GaP using Z-scan technique. The nonlinear optical properties include third-order effects of two-photon absorption and bound-electronic refraction, and fifth-order effects of free-carrier absorption and refractive index change due to the generation of …

    nus Repository record for Z-SCAN STUDIES ON ZNSE, ZNS AND GAP (opens in a new tab) Download file for Z-SCAN STUDIES ON ZNSE, ZNS AND GAP (opens in a new tab)

  2. Measuring Nonlinear Properties of Graphene Thin Films Using Z-Scan Technique

    … measuring the nonlinear parameters, and the Z-scan method has been considered the standard approach due to its simplicity and sensitivity. The main goal of this research was to investigate the thermal nonlinearities of nonfunctionlaized and functionalized graphene thin films without and with …

    arkansas Repository record for Measuring Nonlinear Properties of Graphene Thin Films Using Z-Scan Technique (opens in a new tab)

  3. Experimental Techniques For Nonlinear Material Characterization: A Nonlinear Spectrometer Using A White-light Continuum Z-scan

    … like, white-light continuum pump-probe and Z-scan techniques were used to measure the peak 2PA cross-sections for a number of commercially available photoinitiators. In the new method mentioned above, a high energy, broadband femtosecond white-light continuum is used to replace the single …

    ucf Repository record for Experimental Techniques For Nonlinear Material Characterization: A Nonlinear Spectrometer Using A White-light Continuum Z-scan (opens in a new tab)

  4. Quantitative Fluorescence Studies in Living Cells: Extending Fluorescence Fluctuation Spectroscopy to Peripheral Membrane Proteins

    … membrane. We developed a new method based on z-scan FFS that accounts for the fluorescence contributions from cytoplasmic and membrane layers by incorporating a fluorescence intensity z-scan through the cell. H-Ras-EGFP served as a model system to demonstrate the feasibility of the technique. …

    umn Repository record for Quantitative Fluorescence Studies in Living Cells: Extending Fluorescence Fluctuation Spectroscopy to Peripheral Membrane Proteins (opens in a new tab)

  5. Quantitative Two-Photon Laser Scanning of Living Cells

    Two-photon laser scanning identifies the location and oligomeric state of fluorescently tagged proteins within a living cell. Knowledge of these properties is important because the cell function critically depends on the assembly state of protein complexes, as well as their subcellular …

    umn Repository record for Quantitative Two-Photon Laser Scanning of Living Cells (opens in a new tab)

  6. Techniques For Characterization Of Third Order Optical Nonlinearities

    … for nonlinear spectroscopy − the Dual Arm iii Z-Scan and the Beam Deflection techniques. The Dual Arm Z-Scan technique is an enhancement of the standard Z-Scan technique that allows for the measurement of small nonlinear signals in the presence of large background signals. This technique allows …

    ucf Repository record for Techniques For Characterization Of Third Order Optical Nonlinearities (opens in a new tab)

  7. Propriétés optiques linéaires et non linéaires des couches minces de carbone déposées par ablation laser

    … de la couche mince. La méthode du Z-scan est souvent utilisée afin de mesurer des coefficients optiques non linéaires d'un matériau. Une problématique qui provient de la méthode du Z-scan est le cas où nous utilisons des couches minces trop fragiles et leur structure change de …

    moncton Repository record for Propriétés optiques linéaires et non linéaires des couches minces de carbone déposées par ablation laser (opens in a new tab)

  8. Saturable absorption and two-photon absorption in graphene

    … absorption in graphene by carrying out Z-scan experiments at 780 nm with 1 kHz and 400-fs laser pulses on the monolayer, bilayer and multilayer epitaxial graphene, which have been demonstrated to be high quality graphene samples. Subsequently, we studied the spectral dependence of …

    nus Repository record for Saturable absorption and two-photon absorption in graphene (opens in a new tab) Download file for Saturable absorption and two-photon absorption in graphene (opens in a new tab)

  9. OPTICAL NONLINEARITIES AND TWO-PHOTON-GENERATED CARRIER LIFETIMES IN II-VI COMPOUNDS

    … individually by use of a single-beam Z-scan technique at 532 nm. We have also made the comparison between our experimental measurements and theoretical calculations as well as previous research results, which have shown good agreement. We also report an experimentally simple method for …

    nus Repository record for OPTICAL NONLINEARITIES AND TWO-PHOTON-GENERATED CARRIER LIFETIMES IN II-VI COMPOUNDS (opens in a new tab) Download file for OPTICAL NONLINEARITIES AND TWO-PHOTON-GENERATED CARRIER LIFETIMES IN II-VI COMPOUNDS (opens in a new tab)

  10. Netiesinio lūžio rodiklio matavimas žadinant femtosekundiniais impulsais infraraudonojoje srityje /

    … BK7 in near infrared. Therefore, two separate z-scan systems were constructed, employing 800 nm Ti:sapphire and 1030 nm Yb:KGW laser system radiation as pump. Measurements in NIR (near infrared) should serve as ground work for expanding experiments further into infrared. With used z-scan …

    vilnius Repository record for Netiesinio lūžio rodiklio matavimas žadinant femtosekundiniais impulsais infraraudonojoje srityje / (opens in a new tab)

  11. Biophysical Investigations of Retroviral Assembly Using Novel Quantitative Fluorescence Microscopy Techniques

    … the early stages of the assembly process, z-scan fluorescence microscopy is extended to a dual color (DC) modality. The new DC z-scan technique yielded an order of magnitude improvement the PM binding limit of detection and enabled observation of cooperative binding to the PM in the case of …

    umn Repository record for Biophysical Investigations of Retroviral Assembly Using Novel Quantitative Fluorescence Microscopy Techniques (opens in a new tab)

  12. Nonlinear optical properties of novel nanostructured ion implanted laser ablated silicon using femtosecond pulse excitation

    … properties of the samples was studied by the Z-scan techniques using ~ 100 fs pulses. The Z-scan technique is a relatively simple and direct measurement of both the real and imaginary part of [chi]^{(3)}, where the nonlinear refractive index (n _2) is related to [chi]^{(3)}_{Re} and the …

    njit Repository record for Nonlinear optical properties of novel nanostructured ion implanted laser ablated silicon using femtosecond pulse excitation (opens in a new tab)

  13. Commutation optique dans un cristal photonique à base de silicium

    … autour de I.Spm. À l'aide de la technique du Z-scan, les mesures des coefficients de Kerr et d’absorption de deux photons sont effectuées dans l’échantillon. Les résultats démontrent la présence des effets non-linéaires attendus. Les mesures de la transmission de l'échantillon en fonction de la …

    moncton Repository record for Commutation optique dans un cristal photonique à base de silicium (opens in a new tab)

  14. Optical Self-Phase Modulation in Graphene

    … that lead to the observed behaviour. Using the Z-scan technique, the effects of the wavelength and pulse-duration of the exciting source on the value of n2 were studied. The Z-scan technique exploits light induced selfrefraction to relate the change in transmittance to the value of n2. The …

    waterloo Repository record for Optical Self-Phase Modulation in Graphene (opens in a new tab)

  15. Kristalų netiesinio lūžio rodiklio infraraudonojoje srityje nustatymas /

    … an evaluation method is used for example in z-scan measurements. z-scan technique is distinguished by its high sensitivity and is relatively simple both in experimental execution and in nonlinear refractive index value determination from measured data. However both very high beam shape and …

    vilnius Repository record for Kristalų netiesinio lūžio rodiklio infraraudonojoje srityje nustatymas / (opens in a new tab)

  16. Nonlinear Optical Absorption and Refraction Study of Metallophthalocyanine Dyes

    … in toluene, referred to as SiNc. Using the Z-scan technique, the experiments are performed on both the picosecond and nanosecond timescales at a wavelength of 0.532 μm.

    unt Repository record for Nonlinear Optical Absorption and Refraction Study of Metallophthalocyanine Dyes (opens in a new tab)

  17. THE NONLINEAR OPTICAL PROPERTIES OF CLUSTERS (N-BU4N)4[MO8CU12O8S24] AND (N-BU4N)2[MOCU3OS3(NCS)3]

    … the two clusters, we established an automatic Z-Scan measurement system. We also developed a set of software to control data acquisition processes. With these hardware and software, we conducted open-aperture and closed-aperture Z-scan experiments at different wavelengths and incident irradiances …

    nus Repository record for THE NONLINEAR OPTICAL PROPERTIES OF CLUSTERS (N-BU4N)4[MO8CU12O8S24] AND (N-BU4N)2[MOCU3OS3(NCS)3] (opens in a new tab) Download file for THE NONLINEAR OPTICAL PROPERTIES OF CLUSTERS (N-BU4N)4[MO8CU12O8S24] AND (N-BU4N)2[MOCU3OS3(NCS)3] (opens in a new tab)

Page 1 of 6