Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 29 for “"Zeplin"”.

  1. Bringing back the senses to LUX-ZEPLIN

    The LUX-ZEPLIN (LZ) experiment set world-leading limits for spin-independent WIMP-nucleon interactions above 10 GeV/<em>c</em><sup>2</sup> with its first science run results released in 2022. Background characterisation and a complete understanding of the detector and internal conditions are vital …

    oxford Repository record for Bringing back the senses to LUX-ZEPLIN (opens in a new tab)

  2. Constraining cavern backgrounds for the LUX-ZEPLIN experiment

    … has yet to be directly detected.</p> <p>The LUX-ZEPLIN experiment (LZ) is searching for a popular dark matter particle candidate, weakly interacting massive particles (WIMPs), in the energy range GeV/c2 – TeV/c2. The LZ detector consists of a dual-phase time projection chamber filled with a 7 t …

    oxford Repository record for Constraining cavern backgrounds for the LUX-ZEPLIN experiment (opens in a new tab)

  3. Neutron Activation Backgrounds in the LUX-ZEPLIN Experiment

    … criteria for it to be dark matter. The LUX-ZEPLIN experiment seeks to detect WIMP dark matter through the use of a liquid xenon dual-phase xenon time projection chamber. This technology measures the light and charge signals from WIMP-nucleon interactions at low energies. Whilst the LZ …

    whiterose Download PDF for Neutron Activation Backgrounds in the LUX-ZEPLIN Experiment (opens in a new tab)

  4. Optimizing low-mass WIMP searches in the LUX-ZEPLIN experiment

    … detection has remained elusive. <br><br>The LUX-ZEPLIN (LZ) experiment is a dual-phase LXe time projection chamber designed for the direct detection of dark matter. In its first science run, LZ achieved sensitivity to spin-independent WIMP-nucleon cross sections of 9.2 × 10<sup>−48</sup> …

    oxford Repository record for Optimizing low-mass WIMP searches in the LUX-ZEPLIN experiment (opens in a new tab)

  5. Searches for rare nuclear decays in the LUX-ZEPLIN experiment

    … elusive. Stationed deep underground, the LUX-ZEPLIN (LZ) experiment utilises several tonnes of xenon in a dual-phase time projection chamber to conduct direct searches for particle dark matter. A world-leading limit was recently set by the LZ experiment for interactions between nucleons and …

    oxford Repository record for Searches for rare nuclear decays in the LUX-ZEPLIN experiment (opens in a new tab)

  6. A Search for Dark Matter with the ZEPLIN II Detector

    … (WIMP) with a mass of order 100 GeV/c^2. The ZEPLIN II experiment is a WIMP search experiment that attempts to directly detect WIMP interactions using the two-phase xenon approach. The detector measures both scintillation and ionization generated by interactions in a 31 kg liquid xenon target. …

    tamu Repository record for A Search for Dark Matter with the ZEPLIN II Detector (opens in a new tab)

  7. Measurement of Dissolved Beta Decay Sources in the LUX-ZEPLIN Experiment

    … for probing the WIMP mass range. The LUX-ZEPLIN (LZ) experiment is a 10 tonne LXe TPC searching for the elusive WIMP dark matter. As detector masses increase to maximize sensitivity, background sources in the Xe, such as $^{85}$Kr and $^{39}$Ar, must be reduced to meet background …

    maryland Repository record for Measurement of Dissolved Beta Decay Sources in the LUX-ZEPLIN Experiment (opens in a new tab)

  8. IDENTIFICATION OF TRACE KRYPTON IN THE LUX-ZEPLIN DARK MATTER SEARCH

    … astrophysicists, and cosmologists. The LUX-ZEPLIN (LZ) detector has completed an initial science run finding no evidence for WIMP scattering events. The data excludes scattering cross sections above 6.5x10$^{-48}$ cm$^{2}$ for a WIMP mass of 30 GeV/c$^{2}$. Background contributions from the …

    maryland Repository record for IDENTIFICATION OF TRACE KRYPTON IN THE LUX-ZEPLIN DARK MATTER SEARCH (opens in a new tab)

  9. Electric fields and their implications in the LUX-ZEPLIN time projection chamber

    … continues to evade direct detection. The LUX–ZEPLIN (LZ) experiment, a dual-phase xenon time projection chamber, stands at the forefront of this pursuit. This thesis interrogates the microscopic and macroscopic roles of electric fields in LZ and their consequences for charge transport, event …

    oxford Repository record for Electric fields and their implications in the LUX-ZEPLIN time projection chamber (opens in a new tab)

  10. Radon Detection and 241Am-7Li Source Development for the Lux-Zeplin Dark Matter Experiment

    … direct dark matter search experiment called LUX-ZEPLIN (LZ). Most of my work relates to the preparation of the experiment, namely the measurement of the release of trace amounts of radon gas from detector materials, forming the dominant background component. This work was important to ensure a …

    alabama Repository record for Radon Detection and 241Am-7Li Source Development for the Lux-Zeplin Dark Matter Experiment (opens in a new tab)

  11. Improving the low energy searches of the LUX-ZEPLIN experiment with advanced waveform simulation

    The LUX-ZEPLIN (LZ) experiment is a dual-phase xenon time projection chamber primarily designed to search for weakly interacting massive particles (WIMPs) directly through their scattering interactions with xenon nuclei. LZ sets the current world-leading limits for WIMP masses above 5GeV/c2 with …

    oxford Repository record for Improving the low energy searches of the LUX-ZEPLIN experiment with advanced waveform simulation (opens in a new tab)

  12. Search for dark matter with the LUX–ZEPLIN detector – acoustic sensor performance and detector response

    <p>The LUX-ZEPLIN experiment needs acoustic sensors to monitor the liquid xenon contained in its time projection chamber (TPC) for irregularities that could spoil a stable liquid xenon environment that is required for a dark matter search. I have developed and implemented algorithms that …

    oxford Repository record for Search for dark matter with the LUX–ZEPLIN detector – acoustic sensor performance and detector response (opens in a new tab)

  13. Single Scatter Neutron Background Estimates using Multiple Scatters of Neutrons in the LUX-ZEPLIN Experiment

    … for a viable dark matter candidate. The LUX-ZEPLIN (LZ) experiment uses a dual-phase xenon time projection chamber to search for direct evidence of WIMP dark matter. In rare event searches, comprehensive understanding of background signals is essential, and a particularly important background …

    whiterose Download PDF for Single Scatter Neutron Background Estimates using Multiple Scatters of Neutrons in the LUX-ZEPLIN Experiment (opens in a new tab)

  14. Dark Matter Searches and the Measurement of the Atmospheric Muon Flux with the LUX-ZEPLIN Experiment

    … theoretical and cosmological arguments. The LUX-ZEPLIN experiment employs a dual-phase liquid xenon Time Projection Chamber (TPC) to detect WIMP-nucleon interactions. The TPC is surrounded by a veto system consisting of an instrumented xenon skin layer (Skin) and gadolinium-loaded liquid …

    zurich

  15. A position-sensing system for the top PMT array in the LUX-ZEPLIN dark matter experiment

    <p>LUX-ZEPLIN (LZ) is a next-generation liquid xenon dark matter detection experiment, searching for direct interactions with WIMPs. As it is a low-background experiment using high-purity xenon, the sensors installed to monitor the experiment must be custom-made from a short list of acceptable …

    oxford Repository record for A position-sensing system for the top PMT array in the LUX-ZEPLIN dark matter experiment (opens in a new tab)

  16. Development of the ionisation signal analysis and the thermometry system for the LUX-ZEPLIN direct dark matter detection experiment

    … explain the observed measurements. The LUX-ZEPLIN (LZ) detector is searching for WIMP interactions with xenon nuclei, through both scintillation and ionisation signals. It comprises a time-projection chamber filled with 7 tonnes of liquid xenon, situated at the Sanford Underground Research …

    oxford Repository record for Development of the ionisation signal analysis and the thermometry system for the LUX-ZEPLIN direct dark matter detection experiment (opens in a new tab)

  17. Improvements in Upper Limits of the Neutralino-Proton Cross Section through use of Model-Independent Nuclear Form Factors.

    … dark matter searches such as CDMS, EDELWEISS, ZEPLIN, and other experiments. These cross sections and direct detection rates are generally computed with standard, one or two parameter model-dependent nuclear form factors, which may not exactly mirror the actual form factor for the particular …

    creighton Repository record for Improvements in Upper Limits of the Neutralino-Proton Cross Section through use of Model-Independent Nuclear Form Factors. (opens in a new tab)

Page 1 of 2