Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 8 of 8 for “"Zero Energy Lab"”.

  1. Performance Analysis of Two Alternative Hvac Systems for the Unt Zero Energy Lab

    … and cost considering North Texas climate. In the Zero Energy Lab at the University of North Texas, Denton, TX, the HVAC system of the building assembles with geothermal heat source. Here, water to water heat pump with radiant floor and water to air heat pump with air ducts provide heating & …

    unt Repository record for Performance Analysis of Two Alternative Hvac Systems for the Unt Zero Energy Lab (opens in a new tab)

  2. Field Validation of Zero Energy Lab Water-to-Water Ground Coupled Heat Pump Model

    … a model for the ground-source heat pump at the Zero Energy lab at the University of North Texas, and finding the minimum data required for generating the model. The literature includes many models with different approaches to determine the performance of the heat pump. Each method has its pros …

    unt Repository record for Field Validation of Zero Energy Lab Water-to-Water Ground Coupled Heat Pump Model (opens in a new tab)

  3. A Performance Analysis of Solar Chimney Passive Ventilation System in the Unt Zero Energy Lab

    … solar chimney natural ventilation system in a Zero Energy Lab located at the University of North Texas campus, to figure out performance of the solar chimney. Reduction in the heating and ventilation and air conditioning energy consumption of the house has been also analyzed. The parameters …

    unt Repository record for A Performance Analysis of Solar Chimney Passive Ventilation System in the Unt Zero Energy Lab (opens in a new tab)

  4. Sensitivity and Uncertainty Analysis of Occupancy-related Parameters in Energy Modeling of Unt Zero Energy Lab

    … analysis of occupancy-related parameters using Energyplus modeling method. The model is based on a real building Zero Energy Lab in Discovery Park, at University of North Texas. Four categories of parameters are analyzed: heating/cooling setpoint, lighting, equipment and occupancy. Influence …

    unt Repository record for Sensitivity and Uncertainty Analysis of Occupancy-related Parameters in Energy Modeling of Unt Zero Energy Lab (opens in a new tab)

  5. Multi-year Operation Effect of Geothermal Heat Exchanger on Soil Temperature for Unt Zero Energy Lab

    … due to Ground loop heat exchanger (GLHE) for Zero Energy Research Laboratory (ZØE) which is located in Discovery Park, University of North Texas, Denton, TX. We did 2D thermal analysis GLHP at particular Depth. For simulation we have used ANSYS workbench for pre-processing and FLUENT ANYS as …

    unt Repository record for Multi-year Operation Effect of Geothermal Heat Exchanger on Soil Temperature for Unt Zero Energy Lab (opens in a new tab)

  6. Increasing Effective Thermal Resistance of Building Envelope's Insulation Using Polyurethane Foam Incorporated with Phase Change Material

    … the insulation capability for further building energy savings by reducing the HVAC loadings. During the phase change process between the solid and liquid states, heat is being absorbed or released by PCMs depending on the surrounding temperature. This research explores the benefits of a …

    unt Repository record for Increasing Effective Thermal Resistance of Building Envelope's Insulation Using Polyurethane Foam Incorporated with Phase Change Material (opens in a new tab)

  7. Impact of Green Design and Technology on Building Environment

    … is the primary objective of this study. The Zero Energy Research (ZOE) laboratory, located at the University of North Texas Discovery Park, is analyzed as a case study. Because the ZOE lab is a building that combines various green design elements and energy efficient technologies, such as …

    unt Repository record for Impact of Green Design and Technology on Building Environment (opens in a new tab)

  8. Use of Bio-Product/Phase Change Material Composite in the Building Envelope for Building Thermal Control and Energy Savings

    … as the PCM in the current studies. The building energy savings were investigated by comparing the composite building envelope material with the conventional material in a unique Zero-Energy (ZØE) Research Lab building at University of North Texas (UNT) through building energy simulation programs …

    unt Repository record for Use of Bio-Product/Phase Change Material Composite in the Building Envelope for Building Thermal Control and Energy Savings (opens in a new tab)