Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 268 for “"Zero-Valent iron"”

  1. REDUCTION OF PERCHLORATE BY ZERO VALENT IRON

    … SRS current (100 mA). Perchlorate remediation by zero valent iron was also studied in this research. Acid treatment of iron filings significantly enhanced the reduction rate of perchlorate and the reduction rate was correlated reasonably well by pseudo first order reaction kinetics. A linear …

    ohiolink Repository record for REDUCTION OF PERCHLORATE BY ZERO VALENT IRON (opens in a new tab)

  2. Contaminant degradation using nanosized zero valent iron particles

    Zero-valent iron (ZVI) has been successfully used for the degradation of a wide range of organic contaminants in groundwaters in recent years. The rate of degradation of contaminants by ZVI may be enhanced by use of nanoscale zero valent iron (nZVI) particles which possess higher surface area than …

    unsw Repository record for Contaminant degradation using nanosized zero valent iron particles (opens in a new tab)

  3. Reduction of 2,4,6-Trinitrotoluene with Nanoscale Zero-Valent Iron

    … and contaminant migration.</p> <p>Nanoscale zero-valent iron (NZVI) has been shown to reduce TNT to its less-harmful, biodegradable degradation products. This project involved NZVI synthesis, evaluation of NZVI kinetics, and its behavior in a soil matrix.</p> <p>Results show that NZVI is a …

    ohiolink Repository record for Reduction of 2,4,6-Trinitrotoluene with Nanoscale Zero-Valent Iron (opens in a new tab)

  4. Electrokinetics Enhanced Delivery of Nano-Scale Zero Valent Iron

    Nano-scale zero valent iron (NZVI) has shown promising results for successful in-situ remediation of a wide range of chlorinated hydrocarbons in the subsurface. However, rapid aggregation and subsequent sedimentation limit bare NZVI migration in subsurface systems. A variety of surface …

    uwo Repository record for Electrokinetics Enhanced Delivery of Nano-Scale Zero Valent Iron (opens in a new tab)

  5. Electrochemical deposition of green rust on zero-valent iron

    … contaminant that has been introduced into the environment over many years through industrial and agricultural wastes. Research has been done in the past to investigate PCE degradation by zero-valent iron (ZVI), green rust (GR) and a mixture of both. The combination of ZVI and green rust has been …

    tamu Repository record for Electrochemical deposition of green rust on zero-valent iron (opens in a new tab)

  6. Environmental Remediation of TNT using Nanoscale Zero-Valent Iron Metal

    This research focused on the use of nanoscale zero-valent iron (NZVI) to remediate trinitrotoluene (TNT). Zero-valent iron has demonstrated effective degradation of TNT, however, these particles themselves have significant problems in treating sorbed phase TNT in the aerobic environment. This …

    usf Repository record for Environmental Remediation of TNT using Nanoscale Zero-Valent Iron Metal (opens in a new tab)

  7. Degradation of 17α-Etinylestradiol by Nano-sized Zero Valent Iron

    … to investigate oxidation of EE2 by nano-sized zero valent iron (nZVI). It was decided to use nano-sized rather than macro-sized zero-valent iron due to its reactivity in the degradation of a wide range of organic compounds. Commercial nZVI was utilised throughout this study. The first phase of …

    auckland-ms Repository record for Degradation of 17α-Etinylestradiol by Nano-sized Zero Valent Iron (opens in a new tab)

  8. Pentachlorophenol Dechlorination Using Zero Valent Iron and Nickel-Iron Bimetallics

    Zero Valent Iron (ZVI) systems are used to treat chlorinated phenols (CPs) contaminated waters. In these systems CPs removal occurs by different pathways with a complex dependence on many variables. This research studied pentachlorophenol (PCP) removal by ZVI and Ni/Fe bimetals to decipher some of …

    auckland-ms Repository record for Pentachlorophenol Dechlorination Using Zero Valent Iron and Nickel-Iron Bimetallics (opens in a new tab)

  9. Remediation of Mine Tailings by Nano-Scale Zero-Valent Iron

    … investigate the potential ability of nano-scale zerovalent iron (nZVI) to remediate multiple metal contaminants, specifically in the context of mine tailings. The project began by adopting techniques reported on by investigators researching the remediation effectiveness on metal contaminants of …

    queens Repository record for Remediation of Mine Tailings by Nano-Scale Zero-Valent Iron (opens in a new tab)

  10. Electrochemical remediation of radionuclide- and trichloroethene-contaminated groundwater using zero-valent iron/iron oxides and mineralogical characterization of iron hydroxides formed from zero-valent iron

    … remediation have become popular topics in environmental science and engineering research. Although the zero-valent iron (Fe°)-based reactive barrier has been introduced as a cost-effective remediation technology for groundwaters contaminated by chlorinated organic compounds and reducible …

    utk-theses Repository record for Electrochemical remediation of radionuclide- and trichloroethene-contaminated groundwater using zero-valent iron/iron oxides and mineralogical characterization of iron hydroxides formed from zero-valent iron (opens in a new tab)

  11. Systematic Size Control in the Synthesis of Zero-Valent Iron Nanoparticles

    … in these reactions by cheap and widely available iron complex precursors can be avoided in this method with the introduction of thermodynamic control, which occurs in the form of a magnetic precipitation event that essentially halts nanoparticle growth. Utilizing this synthetic method, the length …

    unm Repository record for Systematic Size Control in the Synthesis of Zero-Valent Iron Nanoparticles (opens in a new tab)

  12. Reactive Transport Modeling of Hexavalent Chromium Treatment by Zero Valent Iron

    Hexavalent chromium (Cr(VI)) is a toxic heavy metal used in various industries, posing risks to human health and the environment. Its reduction to less toxic trivalent chromium (Cr(III)) can be achieved through Permeable Reactive Barriers (PRBs), which are cost-effective systems for groundwater …

    metu Repository record for Reactive Transport Modeling of Hexavalent Chromium Treatment by Zero Valent Iron (opens in a new tab)

  13. DEGRADATION OF 1,2-DICHLOROETHANE WITH NANO-SCALE ZERO VALENT IRON PARTICLES

    The application of nanoscale zero-valent iron particles (nZVI) for abiotic remediation of chlorinated compounds is proving among the most viable technologies for environmental remediation. However, although most polychlorinated C2 compounds are easily dechlorinated by nZVI, 1,2-dichloroethane …

    uwo Repository record for DEGRADATION OF 1,2-DICHLOROETHANE WITH NANO-SCALE ZERO VALENT IRON PARTICLES (opens in a new tab)

  14. Enhanced degradation of persistent organic pollutants by nanoscale zero-valent iron

    … undesirable by-products which entered our environment. Indeed, rapidly-expanding global industrialisation has been accompanied by rapidly-declining availability of clean air, soil and water. Inattention to the environmental impacts of industry during the 20th century and earlier means that …

    adelaide Repository record for Enhanced degradation of persistent organic pollutants by nanoscale zero-valent iron (opens in a new tab)

  15. Isotopic fractionation of chlorinated ethenes during reductive dehalogenation by zero valent iron

    … compounds is reductive dehalogenation using iron metal as the reducing agent. The method involves introducing an iron metal barrier into the flow of groundwater. Zero valent iron reacts with the chlorinated ethenes by either β-elimination or dehydrogenation, depending on the pH and Eh of the …

    newfoundland Repository record for Isotopic fractionation of chlorinated ethenes during reductive dehalogenation by zero valent iron (opens in a new tab)

  16. Mechanism for heterogeneous reduction of selenite by zero valent iron-steel wool.

    … between SeIV and ZVI-SW under anoxic environment using wet chemical analysis and microspectroscopic analysis (X-ray photoelectron spectroscopic) techniques. Bench top experiments kinetic data and microspectroscopic analysis identified a two-step removal mechanism. The main removal …

    wvu Repository record for Mechanism for heterogeneous reduction of selenite by zero valent iron-steel wool. (opens in a new tab)

  17. The Long-Term Viability of a Zero-Valent Iron Permeable Reactive Barrier

    Zero-valent iron permeable reactive barriers (PRB's) hold significant potential as a tool for groundwater remediation. Uncertainties remain, however, as to the effective lifetime of Fe0 barrier technology under full-scale operational conditions. Potential limits on barrier lifetime include …

    portland-state Repository record for The Long-Term Viability of a Zero-Valent Iron Permeable Reactive Barrier (opens in a new tab)

Page 1 of 14