  1. The effect of multiple tightening and untightening on abutment screw and driver head dimensions

    … implant systems: Nobel Biocare, Straumann, and ZimVie. An in vitro experimental study was conducted using thirty new abutment screws (n = 10 per implant system) and manufacturer-specific drivers. Implant analogs were embedded in polymethyl methacrylate (PMMA) pattern resin blocks to ensure rigid …

    temple Repository record for The effect of multiple tightening and untightening on abutment screw and driver head dimensions (opens in a new tab)

  2. Clinical Performance and Outcomes of a Platform Switching, Multi-Level Surface Implant System: A Prospective Clinical Study/Surgical Results

    … of the T3 Pro dental implant system from ZimVie. The T3 Pro implant incorporates a multi-level surface, with acid-etched, fine-micron features and coarse-micron features along the entire surface of the implant as well as sharp cutting flutes and self-tapping thread design with increasing …

    umn Repository record for Clinical Performance and Outcomes of a Platform Switching, Multi-Level Surface Implant System: A Prospective Clinical Study/Surgical Results (opens in a new tab)

  3. Implant Overdenture Abutment Loosening under Hyperbaric Conditions

    … as opposed to one cycle/dive. Methods: 36 ZimVie Tapered Screw Vent Implants with a 3.5mm diameter implant platform, and a 2.5mm diameter (and 1.5mm deep) internal hexagon were placed into resin blocks. LOCATOR® abutments were torqued to 30 N-cm with a digital torque meter. The implants …

    wvu Repository record for Implant Overdenture Abutment Loosening under Hyperbaric Conditions (opens in a new tab)

  4. Evaluation of Finger-Tightening Torque Applied to Implant Healing Abutments by Dental Providers with Varying Experience and Physical Characteristics: An In-vitro Study.

    … participant was instructed to finger-tighten a ZimVie healing abutment into a securely clamped implant fixture in a manner consistent with their routine clinical practice. The applied torque was measured and recorded using a digital torque device (Cedar DID-4A). In addition, participants …