Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 7 of 7 for “"ZnS:Ag"”
-
Hydrothermal Reaction Synthesis and Characterization of ZnS:Ag Scintillator
… special nuclear materials (SNMs) based on ZnS:Ag. The effects of the pH of the precursor solution on ZnS:Ag synthesized under various conditions of temperature and time by the hydrothermal reaction synthesis method (200℃ for 6 hours, pH from 1 to 12; 100℃ for 2 hours, pH from 7 to 12;60℃ …
-
Novel Scintillator Development for High Rate Capability Neutron Scattering Detectors
… a growing priority. The current state-of-the-art ZnS:Ag/<sup>6</sup>LiF scintillation detectors are count rate limited by fundamental luminescence mechanisms. In this work two novel scintillators for high count rate capability neutron detection applications are explored: ZnO:Zn/<sup>6</sup>LiF and …
-
An investigation into the growth and characterisation of thin film radioluminescent phosphors for neutron diffraction analysis
… and improved spatial resolution. The current ZnS:Ag,Cl phosphor used at ISIS was characterised in terms of its luminescent emission properties and comparisons were made to thin films of potential phosphor materials and the source material used to create the thin films. The phosphors were …
-
Gamma-Blind Fast Neutron Detection for Spent Nuclear Fuel Characterization
… volume made of a silver-activated zinc sulfide (ZnS:Ag) scintillator powder mixed with a transparent epoxy, with wavelength-shifting fibers (WLSFs) embedded in this mixture. Neutron detection happens via elastic scattering with hydrogen in the optical epoxy. The resulting recoil protons activate …
-
Field Method for Gross Alpha- And Beta- Emitting Radionuclide Detection in Environmental Aqueous Solutions
… E600 detection system utilizing a phoswich (ZnS:Ag) plastic scintillator mounted on a modified SPA-1A Probe (Thermo Eberline, LLC.) The field method was evaluated against a modified EPA method consisting of the iSolo® Alpha/Beta Counting System which utilized a passivated implanted planar …
-
Monte Carlo Simulation of Neutron Detectors
… scintillator characteristics are quantified. For ZnS:Ag particles in a lithiated glass matrix, it is found that dopant particle radii of 1 micron or less result in approximately Gaussian-shaped pulse height spectra and dopant particle radii of 5 microns or less result in practically all neutron …