Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 105 for “"a contrast agent"”.

  1. HYPOXIA-INDUCED DEOXYHEMOGLOBIN; A CONTRAST AGENT FOR CEREBRAL PERFUSION IMAGING

    … imaging (MRI) and trace the passage of a contrast agent through the vascular network. Although gadolinium-based contrast agents (GBCA) are most commonly used clinically, they come with notable disadvantages, including discomfort, the need for intravenous injection, potential deposition in …

    toronto-retro Repository record for HYPOXIA-INDUCED DEOXYHEMOGLOBIN; A CONTRAST AGENT FOR CEREBRAL PERFUSION IMAGING (opens in a new tab)

  2. Iron oxide nanoparticles as a contrast agent for thermoacoustic tomography

    An exogenous contrast agent has been developed to enhance the contrast achievable in Thermoacoustic Tomography (TAT). TAT utilizes the penetration depth of microwave energy while producing high resolution images through acoustic waves. A sample irradiated by a microwave source expands due to …

    tamu Repository record for Iron oxide nanoparticles as a contrast agent for thermoacoustic tomography (opens in a new tab)

  3. Highly-iodinated fullerene as a contrast agent for X-ray imaging

    The first fullerene-based X-ray contrast agent (CA) has been designed, synthesized, and characterized. The new CA is an externally functionalized derivative of C60 that is conceptually based on contemporary X-ray CA, all of which use iodine as the X-ray attenuating vehicle and are built on the …

    rice Repository record for Highly-iodinated fullerene as a contrast agent for X-ray imaging (opens in a new tab)

  4. Iodixanol as a contrast agent in a fibrin hydrogel for endodontic applications

    … fibrin hydrogel radiopaque using an iodine-based contrast agent (iodixanol) approved for systemic application. Fibrin hydrogels were prepared from a fibrin sealant (Tisseel) using either an isotonic iodixanol solution (Visipaque 320, test) or Tris buffer (control) as a diluent. Gelation kinetics, …

    zurich Repository record for Iodixanol as a contrast agent in a fibrin hydrogel for endodontic applications (opens in a new tab)

  5. Assessment of fluorescently-labeled gold nanoparticles in mice as a contrast agent for micro-computed tomography and optical projection tomography

    Objectives: Contrast agents are required to be able to view and differentiate tissues in 3-D computed tomography (CT) due to similarities in density. Pre-clinical contrast agents used for radiology are not visible when viewed histologically, and visa versa. Identifying a single agent that is …

    ubc Repository record for Assessment of fluorescently-labeled gold nanoparticles in mice as a contrast agent for micro-computed tomography and optical projection tomography (opens in a new tab) Download PDF for Assessment of fluorescently-labeled gold nanoparticles in mice as a contrast agent for micro-computed tomography and optical projection tomography (opens in a new tab)

  6. Chemical Modification of Bovine Milk Exosomes, the Biological Nanoparticles of the Future, as a Contrast Agent and Drug Delivery Vehicle

    … milk derived exosomes as (1) an ultrasound contrasting agent and (2) a targeted and triggered chemotherapeutic drug delivery vehicle. As an ultrasound contrast agent, raw and pasteurized bovine milk exosomes were tested and found to be capable of echogenicity without altering the ability to …

    ndsu Repository record for Chemical Modification of Bovine Milk Exosomes, the Biological Nanoparticles of the Future, as a Contrast Agent and Drug Delivery Vehicle (opens in a new tab)

  7. Magnetomotive ultrasound for nanomedicine : a mechanistic approach to detection, evaluation and safety assessment

    … magnetically induced motion, transferred from a contrast agent to the tissue of interest. The tissue response to this perturbation is related to its mechanical properties, and thereby to cancer progression. Typically, the contrast agent consists of magnetic nanoparticles; These can be …

    lund Repository record for Magnetomotive ultrasound for nanomedicine : a mechanistic approach to detection, evaluation and safety assessment (opens in a new tab) Download PDF for Magnetomotive ultrasound for nanomedicine : a mechanistic approach to detection, evaluation and safety assessment (opens in a new tab)

  8. Magnetic resonance imaging of transmembrane water permeability for detection of cell death

    … and clinical MRI system. The AXR is shown as a contrast agent-free early cell death imaging biomarker in vitro and in vivo. A pilot study in patients demonstrates the translatability of AXR measurements to the clinic.

    greece Repository record for Magnetic resonance imaging of transmembrane water permeability for detection of cell death (opens in a new tab)

  9. Engineering functionalized gold nanoparticles as a molecular-specific contrast agent to enhance optoacoustic detection of breast cancer cells

    … including breast. Delivering molecular specific contrast agents to breast cancer cells would enhance the sensitivity and specificity of imaging methods to detect cancer foci at earlier stages, when complete cure is possible. Optoacoustic tomography (OAT) is a non-invasive imaging modality that …

    utmb Repository record for Engineering functionalized gold nanoparticles as a molecular-specific contrast agent to enhance optoacoustic detection of breast cancer cells (opens in a new tab)

  10. ENERGY DEPENDENT SYSTEMATIC ERRORS IN DUAL-ENERGY X-RAY COMPUTED TOMOGRAPHY

    … a high atomic number element such as iodine in a contrast agent was present in the region of interest. The results derived from the analysis agreed with a simple mathematical model formulated to analytically quantity the errors in terms of an equivalent DECT system using two monoenergetic spectra. …

    nus Repository record for ENERGY DEPENDENT SYSTEMATIC ERRORS IN DUAL-ENERGY X-RAY COMPUTED TOMOGRAPHY (opens in a new tab) Download file for ENERGY DEPENDENT SYSTEMATIC ERRORS IN DUAL-ENERGY X-RAY COMPUTED TOMOGRAPHY (opens in a new tab)

  11. Strategies for Temporal and Spectral Imaging with X-ray Computed Tomography

    … resolution, temporal resolution, and material contrast. This study presents a set of tools that achieve these improvements. These tools include the mathematical formulation and computational implementation of algorithms for calibration, image reconstruction, and image analysis with our custom …

    duke Repository record for Strategies for Temporal and Spectral Imaging with X-ray Computed Tomography (opens in a new tab)

  12. Nanoparticle-enhanced MRI for prostate cancer: A paradigm shift in detecting lymph node metastases

    … study shows that MRI using nanoparticles as a contrast agent helps detect prostate cancer spread to lymph nodes that often remain invisible with standard imaging. Healthy lymph nodes absorb the iron oxide ('rust') nanoparticles and become invisible on the scan, while lymph nodes containing …

    radboud Repository record for Nanoparticle-enhanced MRI for prostate cancer: A paradigm shift in detecting lymph node metastases (opens in a new tab) Download PDF for Nanoparticle-enhanced MRI for prostate cancer: A paradigm shift in detecting lymph node metastases (opens in a new tab)

  13. Optical Contrast Agents to Distinguish Benign Inflammation from Neoplasia in Epithelial Tissues

    … describes research to optimize optical molecular contrast agents to observe architectural, metabolic, and biomolecular changes from inflammation and cancer in the gastrointestinal tract. My goal was to: 1) understand the limitations of autofluorescence imaging for cancer detection, 2) image …

    rice Repository record for Optical Contrast Agents to Distinguish Benign Inflammation from Neoplasia in Epithelial Tissues (opens in a new tab)

  14. Application of resting-state fMRI methods to acute ischemic stroke

    … imaging (DWI) and dynamic susceptibility contrast-enhanced (DSC) perfusion-weighted imaging (PWI) are commonly employed in clinical practice and in research to give pathophysiological information for patients with acute ischemic stroke. DWI is thought to roughly reflect the severely …

    qucosa-diss

  15. Kidney segmentation in 4-dimensional dynamic contrast- enhanced MR images : A physiological approach

    Four-dimensional dynamic contrast enhanced-magnetic resonance imaging (4-D DCE-MRI) is an emerging clinical tool in paediatric urology. It involves administration of a contrast agent whose journey through the kidneys is monitored over time.This thesis proposes two types of techniques to segment …

    nus Repository record for Kidney segmentation in 4-dimensional dynamic contrast- enhanced MR images : A physiological approach (opens in a new tab) Download file for Kidney segmentation in 4-dimensional dynamic contrast- enhanced MR images : A physiological approach (opens in a new tab)

  16. PHOTOACOUSTIC MICROSCOPY OF MALIGNANT MELANOMA IN THE IN VIVO MOUSE MODEL

    … These drawbacks range from the need to use toxic contrast agents to a lack of penetration depth and sufficient contrast. Photoacoustic microscopy improves on these techniques by utilizing optical absorption of biological components and acquiring acoustic waves from optical stimulation, yielding …

    ku Repository record for PHOTOACOUSTIC MICROSCOPY OF MALIGNANT MELANOMA IN THE IN VIVO MOUSE MODEL (opens in a new tab)

  17. A study of the imaging of contrast agents for use in computerised tomography

    … body. In medical diagnostic imaging using CT, contrast agents are administered to patients resulting in increased attenuation of the beam in the areas where the contrast agent resides. The increased contrast results in the easier and more accurate visualisation of abnormalities. In …

    dcu Download PDF for A study of the imaging of contrast agents for use in computerised tomography (opens in a new tab)

  18. Nanoengineered contrast agents for biophotonics: Modeling and experimental measurements of gold nanoshell reflectance

    The growing interest in using exogenous agents to enhance the subtle differences between optical signatures of normal and cancerous tissue, has spurred the development of novel nanoparticulate agents that exhibit desirable optical responses and at the same time, used to target biomolecular markers …

    rice Repository record for Nanoengineered contrast agents for biophotonics: Modeling and experimental measurements of gold nanoshell reflectance (opens in a new tab)

  19. Polivinilpirolidonu stabilizuotų aukso nanodalelių sintezės optimizavimas, savybių įvertinimas ir panaudojimas in Vivo /

    … and stability of AuNP dependence on reagents and investigate its further use in imaging in vivo. 25 different synthesis products of AuNP were made by varying the concentrations of MES monohydrate and sodium hydroxide (NaOH) reagents. Synthesis was made at room temperature, by mixing MES …

    vilnius Repository record for Polivinilpirolidonu stabilizuotų aukso nanodalelių sintezės optimizavimas, savybių įvertinimas ir panaudojimas in Vivo / (opens in a new tab)

Page 1 of 6