Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 14 of 14 for “"abutment design"”
-
Development of abutment design standards for local bridge designs
<p>Several superstructure design methodologies have been developed for low-volume road bridges by the Iowa State University Bridge Engineering Center; however, to date, no standard abutment designs have been developed. Thus, there was a need to establish an easy-to-use design methodology in …
-
An In Vitro Evaluation Of Abutment Design For Anterior Zirconia Resin Bonded Restorations
… search for the ideal conservative preparation design providing maximum retention is critical to improve the life span of these restorations. Purpose: This in vitro evaluation measured and compared the resistance and retention created with different abutment preparation designs with a zirconia …
-
Permeability and lateral earth pressure in granular backfill against bridge abutments
<p>In bridge abutment design, Wisconsin DOT assumes the granular backfill material used behind bridge abutments as free-draining and no hydrostatic pressures are applied on the wall. This research study was undertaken to investigate if backfill materials meet the assumption of a freely-drained …
-
The behaviour of soil behind full-height integral abutments
… have no bearings or joints between the decks and abutments, thus they can significantly reduce maintenance requirements and costs over the bridge life-time. The use of integral bridges has been encouraged over the past decade in the UK. However, because of the integral connection between thee …
-
Comparison of limit states design with working stress design for shallow foundations
Bridge foundations have traditionally been designed using working stress methods, but the new Canadian Highway Bridge Design Code (draft CHBDC) now specifies a limit states design procedure for these structures. The main objective of this study was to compare working stress design (WSD) with limit …
-
Influence of Relative Compaction on Passive Resistance of Abutments with Mechanically Stabilized Earth (MSE) Wingwalls
… helps predict the capacity of the wingwalls in abutment design and the amount of allowable wall deflection before pullout of the backfill reinforcement occurs. Three methods were used to model the measured passive force-displacement curves of each test. Overall, the computed curves were in good …
-
On percutaneous implants fate and feature
… investigate skin reactions around percutaneous abutments in the facial and retroauricular regions. Secondary objectives were to investigate the number of lost extraoral implants and their co-morbidity over time, for example complications because of skin reactions due to the skinpenetrating …
-
Soil-structure interactions due to cyclic translations of integral abutment
… soil-structure interactions due to cyclic abutment translations and the mechanisms causing soil settlement/heave and escalation of lateral earth pressure behind the integral abutment. In addition, a comparative study of the mitigation performance of two compressible inclusion materials in …
-
On loading protocols and abutment use in implant dentistry. Clinical studies.
… of immediate or delayed loading and the use of abutments in implant dentistry with regard to peri-implant tissues and the effect of risk parameters. Methodology: Fifty partially edentulous patients each received three Brånemark TiUnite™ implants. The patients were randomly assigned to a test …
-
Investigating serviceability issues related to thermal movement accommodation in bridges
… ensuring a serviceable, long-term structure is designed and built. The most traditional approach to accommodating this movement involves the use of movement joints placed at the ends of the bridge deck. These movement joints are often fitted with a rubber device to prevent excess drainage from …
-
Evaluating the Effect of the Protector Cap Technique for Castable Implant Abutments on Reverse Torque Values
… complication reported regarding the implant abutment is screw loosening attributed to masticatory forces and insufficient preload torque. Purpose: The purpose of this study is to evaluate the differences in reverse torque value between UCLA abutments with no casting performed, UCLA abutments …
-
Advancing bridge engineering: From state-of-the-practice to state-of-the-art
… and localized failures. Establishing well-designed closure joints between the superstructure and substructure ensures structural continuity and efficient load transfer, preventing stress concentrations and safeguarding the bridge's overall service life. Moreover, selecting an appropriate …
-
HEALING AND REMODELING OF CONNECTIVE TISSUE GRAFT AROUND IMPLANTS WITH POOR KERATINIZED MUCOSA.INFLUENCE OF PROVISIONALIZATION TIMING (DELAYED VS IMMEDIATE) USING BOPT ABUTMENTS.A CLINICAL OBSERVATIONAL CONTROLLED PILOT STUDY.
… augmentation around dental implants using BOPT abutments. Materials and Methods : Overall, 13 patients have been enrolled. A total amount of 21 implants have been placed and they have been alternatively assigned to the case (immediate provisionalization) or control group (delayed …
-
Emergence Profile in Implant-supported Fixed Restorations: an up to 3 Years Imagiologic Follow-up Retrospective Analysis
Introduction: Prosthetic contour design may influence peri-implant tissue adaptation and marginal bone stability. This study evaluated the association between emergence angle (EA), transmucosal abutment height (TmAH), and marginal bone-level changes around bone-level implants over a follow-up …