Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 64 for “"accelerated test"”.

  1. Reliability evaluation of liquid crystal displays under accelerated test conditions

    … liquid crystal dis-plays.</p><p>Reliability life testing was done on variety of LCD samples under different operating conditions. All the besting was done under accelerated conditions, including high temperature of 85°C and relative humidity of 70%. A number of failure modes were identified in …

    njit Repository record for Reliability evaluation of liquid crystal displays under accelerated test conditions (opens in a new tab)

  2. Reliability evaluation of liquid crystal displays under accelerated test conditions

    … To accomplish this, reliability life testing was done on different kinds of LCD samples under different operating conditions. The tests were carried out on the samples of two different vendors at two different temperatures. No humidity was added in any test.</p><p>Vendor No. 1</p><p>1. …

    njit Repository record for Reliability evaluation of liquid crystal displays under accelerated test conditions (opens in a new tab)

  3. External sulfate attack of concrete : an accelerated test method, mechanisms, and mitigation techniques

    … most commonly referred standardized laboratory test method to determine sulfate resistance of blended portland cement mixtures, does not always link well to field performance and may take up to 18 months to complete. The research program presented in this dissertation investigates various issues …

    texas Repository record for External sulfate attack of concrete : an accelerated test method, mechanisms, and mitigation techniques (opens in a new tab)

  4. A review and development of accelerated test methods for anti-corrosive organic coatings

    … environmentally friendly coatings. The immersion test has also incorporated a temperature cycle which proved effective at separating ‘good’ coatings within a short timeframe. Results showed good correlation between ENM and salt spray testing. Work is also reported which was done with the aim of …

    northampton Repository record for A review and development of accelerated test methods for anti-corrosive organic coatings (opens in a new tab) Download PDF for A review and development of accelerated test methods for anti-corrosive organic coatings (opens in a new tab)

  5. Predicting the performance of activated carbon filters at low concentrations using accelerated test data

    … when exposed to low indoor concentrations, using accelerated tests at high concentrations. A comprehensive time-dependent model was proposed for predicting the performance of an in-duct GAC filter under the conditions relevant to the actual applications. The model integrates both pore diffusion …

    concordia Download PDF for Predicting the performance of activated carbon filters at low concentrations using accelerated test data (opens in a new tab)

  6. Use of Response Surfaces in the Design of a Simple Step Stress Accelerated Test Plan

    In designing accelerated testing plans, cost is a factor that is missing in much of the literature. This paper explicits considers cost by developing an optimization model with the objective to minimize costs for a simple step stress accelerated test plan. Two methodologies are employed. One is an …

    arkansas Repository record for Use of Response Surfaces in the Design of a Simple Step Stress Accelerated Test Plan (opens in a new tab)

  7. Development of an accelerated test method to determine the stress crack resistance of high-density polyethylene

    The Notched Constant Ligament Stress (NCLS) test, ASTM F2136, (1) is a test method that measures the slow crack growth (SCG) in High Density Polyethylene (HDPE). The NCLS test requires a notch on all test specimens to act as a stress concentration at that point so crack propagation can be easily …

    umn Repository record for Development of an accelerated test method to determine the stress crack resistance of high-density polyethylene (opens in a new tab)

  8. Accelerated Test Method (ATM) for the Evaluation of External Sulfate and Chloride Attack on Concrete Using Artificial Climate Environment (Ace): An Assessment of Methodology

    This study seeks to investigate a testing methodology that utilizes accelerated testing methods (ATM) in conjunction with nondestructive testing methods (NDT) to assess destructive ion attacks on concrete. Through the testing of concrete samples, the impacts of chloride and sulfate ions on concrete …

    gsu Repository record for Accelerated Test Method (ATM) for the Evaluation of External Sulfate and Chloride Attack on Concrete Using Artificial Climate Environment (Ace): An Assessment of Methodology (opens in a new tab)

  9. EFFECT OF MECHANICAL VIBRATION ON PLATINUM PARTICLE AGGLOMERATION AND GROWTH IN PROTON EXCHANGE MEMBRANE FUEL CELL CATALYST LAYER

    … mechanical vibration on the catalyst layer an accelerated test with potential cycling was specially designed to simulate a typical vehicle driving condition. The length of the accelerated test was designed to be 300 hour with potential cycling comprised of idle running, constant load, triangle …

    temple Repository record for EFFECT OF MECHANICAL VIBRATION ON PLATINUM PARTICLE AGGLOMERATION AND GROWTH IN PROTON EXCHANGE MEMBRANE FUEL CELL CATALYST LAYER (opens in a new tab)

  10. Laboratory and field investigations on the use of lithium nitrate to prevent or mitigate alkali-silica reaction

    … to this project was the investigation of a new test method for reactive aggregates. A more reliable accelerated test method was sought for determining an aggregates susceptibility to alkali-silica reaction. Also, a new test method was utilized in finding faults associated with existing …

    texas Repository record for Laboratory and field investigations on the use of lithium nitrate to prevent or mitigate alkali-silica reaction (opens in a new tab) Restricted access

  11. Conductive anodic filament reliability of fine-pitch through-vias in organic packaging substrates

    … and halogen-free substrates with improved test structure designs including different conductor spacing and geometry. Accelerated test condition (temperature, humidity and DC bias voltage) was used to investigate the effect of conductor spacing and substrate material influence on insulation …

    gatech Repository record for Conductive anodic filament reliability of fine-pitch through-vias in organic packaging substrates (opens in a new tab)

  12. Effects of accelerated lifetime test parameters and failure mechanisms on the reliability of electronic assemblies

    This dissertation presents the results of accelerated reliability assessment methods employed on lead-free component board assemblies. Temperature cycling and mechanical shock tests are commonly used to assess the reliability of portable electronic products. Higher acceleration factors can be …

    aalto Repository record for Effects of accelerated lifetime test parameters and failure mechanisms on the reliability of electronic assemblies (opens in a new tab)

  13. Development of vibration loading profiles for accelerated durability tests of ground vehicles

    The accelerated durability test is an important part for design and manufacturing ground vehicles. It consists of test designed to quantify the life characteristics of a ground vehicle component under normal use conditions by testing the unit at higher stress levels to accelerate the occurrence of …

    manitoba Repository record for Development of vibration loading profiles for accelerated durability tests of ground vehicles (opens in a new tab)

  14. MODELING RATE DEPENDENT DURABILITY OF LOW-Ag SAC INTERCONNECTS FOR AREA ARRAY PACKAGES UNDER TORSION LOADS

    … with select lead-free solders. A torsion test setup is used to apply displacement controlled loads on the test board. Accelerated test load profile is experimentally determined. Torsion test is carried out for all the components under investigation to failure. Strain-rate dependent …

    maryland Repository record for MODELING RATE DEPENDENT DURABILITY OF LOW-Ag SAC INTERCONNECTS FOR AREA ARRAY PACKAGES UNDER TORSION LOADS (opens in a new tab)

Page 1 of 4