Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"acceleration voltage."”.

  1. Thermal in situ TEM experiment on nanoscale indium islands

    … temperature from solid to liquid state. The acceleration voltage, the illumination area and the beam current are the three main parameters of the incident electron beam influencing the amount of induced beam heating in a sample. Effect of the acceleration voltage at 120 and 200 kV is …

    chalmers Repository record for Thermal in situ TEM experiment on nanoscale indium islands (opens in a new tab)

  2. Scanning ionoluminescence microscopy with a helium ion microscope

    … there exists a proportional relationship between acceleration voltage and ionoluminescent signal in the ORIONR PLUS, this relationship is also exhibited in CL. However, when normalised for current and acceleration voltage there appears to be no samples that show greater luminescence under …

    soton Download PDF for Scanning ionoluminescence microscopy with a helium ion microscope (opens in a new tab)

  3. Construction and testing of a miniature fusion neutron generator using inertial electrostatic confinement principles

    … were made. It was found that adding a second acceleration grid outside of the electron emitting filaments was required to maintain an ion current between the grids while they were floating at an acceleration voltage. The geometry of the outer acceleration grid was used to control the amount of …

    texas Repository record for Construction and testing of a miniature fusion neutron generator using inertial electrostatic confinement principles (opens in a new tab)

  4. Electron beam lithography of molecular glass resist films prepared by physical vapor deposition

    … of beam diameters down to 2.1 nm for the acceleration voltage of 20 kV under optimized conditions. This allows the realization of feature elements in the nanometer scale. The continuous work with this exposure tool during this thesis lead to the identification of external and internal tool …

    bayreuth Repository record for Electron beam lithography of molecular glass resist films prepared by physical vapor deposition (opens in a new tab)

  5. Microchannel Plates in Mass Spectrometer Instruments for Spacecraft

    … the source and mass dependent entry, heating and acceleration mechanisms. However, most ion composition instruments are not able to clearly distinguish between some of the heavy ions involved in these processes, particularly N+ and O+. This thesis aims to test a new design of a Time-of-Flight mass …

    unh-thes Repository record for Microchannel Plates in Mass Spectrometer Instruments for Spacecraft (opens in a new tab)

  6. Ultrafast single-electron diffraction at 100 keV and investigation of carbon-nanotube dynamics

    … beamline, “UED2”, where the electron acceleration voltage is upgraded from 30 to 100 kV, which allows the investigation of significantly thicker samples. This is decisively widening the range of complex materials that can be studied. In the experiment, electron pulses are generated by …

    lmu-germany Repository record for Ultrafast single-electron diffraction at 100 keV and investigation of carbon-nanotube dynamics (opens in a new tab)

  7. Laser-Spark Multicharged Ion Implantation System ‒ Application in Ion Implantation and Neural Deposition of Carbon in Nickel (111)

    … position relative to target surface, and the acceleration voltage are described. Up to C4+ are observed. When no acceleration voltage is applied between the carbon target and a grounded mesh in front of the target, ion energies up to ~400 eV/charge are observed. The time-of-flight signal is …

    odu Repository record for Laser-Spark Multicharged Ion Implantation System ‒ Application in Ion Implantation and Neural Deposition of Carbon in Nickel (111) (opens in a new tab)

  8. Nanomechanics with electron beam: detection and control of motion

    … parameters such as position, beam current and acceleration voltage. The model was tested experimentally by varying the current of an electron beam and its distance from the edge of grounded and isolated cantilevers.<br/><br/>• Driving oscillations of a nanomechanical beam can lead to a bistable …

    soton Download PDF for Nanomechanics with electron beam: detection and control of motion (opens in a new tab)

  9. CYTOTOXIC EFFECTS OF DENTAL IMPLANT DEBRIS AFTER DECONTAMINATION TREATMENT USING ER:YAG LASER

    … Scanning electron microscopy in a high-vacuum acceleration voltage with energy-dispersive X-ray was used to evaluate the morphology and elemental composition of the collected particles and dental implant samples. A firefly luciferase assay was used to determine the cell viability 48 hours, 72 …

    temple Repository record for CYTOTOXIC EFFECTS OF DENTAL IMPLANT DEBRIS AFTER DECONTAMINATION TREATMENT USING ER:YAG LASER (opens in a new tab)

  10. Magnetotransport Studies of Mn Ion-Implanted Nanowires

    … under varying conditions, e.g., ion fluence and acceleration voltage. The implantation process was carefully analyzed and optimized within the research project. The resulting Mn-concentration in the nanowires ranges from 0.0001% to 5%. The implantation was carried out at elevated temperatures to …

    lund Repository record for Magnetotransport Studies of Mn Ion-Implanted Nanowires (opens in a new tab) Download PDF for Magnetotransport Studies of Mn Ion-Implanted Nanowires (opens in a new tab)

  11. A Deuterium-Deuterium Neutron Generator-Based Neutron Capture Therapy System for Brain Tumors

    … to maintain and manipulate, require high voltage, and cannot be widely installed in clinical settings. A deuterium-deuterium (DD) neutron generator is a competitive alternative for neutron source due to its low cost, compact size, low acceleration voltage, and relatively simple …

    purdue-thes Repository record for A Deuterium-Deuterium Neutron Generator-Based Neutron Capture Therapy System for Brain Tumors (opens in a new tab)

  12. Resistive switching in ferroelectric polycrystalline Yttrium Manganese Oxide thin films

    … which exhibits a hysteresis loop in the current-voltage characteristics. Resistive switching refers to reversible non-volatile change in state of the resistance. There exists a wide range of materials which show resistive switching i.e, phase change materials are used in today’s technology which …

    qucosa-diss

  13. Design, Analysis and Optimization of a Cherenkov radiation based sub-mm/THz BWO

    … created and implemented. To alleviate the high acceleration voltage required for the electron beam in the BWO using the DD-PC based SWS, the Axial loaded Double Defected Photonic Crystal (ADD-PC) based SWS was implemented at 200GHz. Starting from the band gap diagram, the ADD-PC based SWS was …

    waterloo Repository record for Design, Analysis and Optimization of a Cherenkov radiation based sub-mm/THz BWO (opens in a new tab)

  14. Microstructural characterisation of novel nitride nanostructures using electron microscopy

    … and ZnO which increased with increasing acceleration voltage suggesting knock-on effects driving the change. PL data was consistent with the bandgap of Zn<sub>3</sub>N<sub>2</sub> blue shifted from 1.1eV to around 1.8eV, confirming the potential of the material for application as a …

    oxford Repository record for Microstructural characterisation of novel nitride nanostructures using electron microscopy (opens in a new tab)

  15. Micro-computed tomography in caries research

    … we strongly recommended to consider the limited acceleration voltage of the μCT 20 system and to limit sample evaluation to 6-mm thickness which is already an advantage over other analytic approaches which require the preparation of very thin, micrometric-sized samples. The correlation of …

    lmu-germany Repository record for Micro-computed tomography in caries research (opens in a new tab)

  16. Micro-Structure of Functional Particles and Particle Systems

    … ratio of the carbon K-edge when lowering the acceleration voltage of TEM, which indicates the 300 kV electron beam modifies the graphitic carbon into the amorphous carbon. A high temperature variant of the AG-like amorphous carbon is presented. The bonding state of carbon atoms is studied by …

    cau-kiel Repository record for Micro-Structure of Functional Particles and Particle Systems (opens in a new tab)

  17. Diagnostika polovodičových materiálů metodou EBIC

    Diplomová práce je zaměřena na diagnostiku polovodičových materiálů metodou EBIC (měření proudů indukovaných svazkem), stanovování doby života minoritních nosičů, resp. jejich difuzní délky. V teoretické části práce je uveden princip rastrovacího elektronového mikroskopu, jeho charakteristické …

    brno-tech Repository record for Diagnostika polovodičových materiálů metodou EBIC (opens in a new tab)