Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 39 for “"acetabular cup"”.
-
Development of an optimum acetabular cup prosthesis
… art Finite Element Analysis to produce a novel acetabular cup prosthesis. An investigation into current static and fatigue testing procedures for acetabular cup prostheses has identified current strengths and weakness and proposes a cheap, fast method that is closer to anatomical loading …
-
A study on stability of an all polyethylene pressfit acetabular cup
The primary stability of a pressfit acetabular cup is crucial for its proper performance due to the lack of screws or cement. The primary stability is only given by the pressfit, whereas the secondary fixating derives from osseointegration of the implant. While cemented cups are able to be fully …
-
Development of a novel acetabular cup component for large bearing total hip arthroplasty
… development of a more biomechanically compliant acetabular component. Carbon fibre reinforced polyetheretherketone (CFRPEEK) has been identified as a potential bearing material for orthopaedic applications due to its proven mechanical and chemical properties, and its biocompatibility. This thesis …
-
Cost effective, reliable implantation of acetabular cups in Total Hip Arthroplasty
Correct positioning of the acetabular cup is critical for success within TotalHip Arthroplasty. Malpositioning of the acetabular cup contributes to manycomplications, all of which lead to revision surgery. Despite recognition of theimportance of correct orientation, there is no consensus on what …
-
Clinical Significance of Hip Separation in Metal on Polyethylene, Metal on Metal, and Ceramic on Ceramic THA Due to Resonant and Energy Dispersion Effects
<p>Femoral head sliding within the acetabular cup does occur in THA. Since it is<br />known that impact conditions can lead to component ringing, the present study<br />investigates the vibrational response of variable bearing surface materials. A further understanding of the physical response …
-
Utvärdering av en joystickstyrd robotarms noggrannhet och repeterbarhet Vid placering av acetabularkopp för total höftledsartroplastik
… the correct positioning and orientation of the acetabular cup, one of the components of the hip prosthesis, is crucial to avoid complications. Conventionally, the placement of the acetabular cup is performed manually by the surgeon, which places high demands on precision and experience; however, …
-
Klinische und radiologische Ergebnisse nach Hüftprothesenwechsel durch Implantation eines kranial aufgesockelten Revisionspfannensystems
… During the last years there was an increase of acetabular cup revisions. Furthermore the quality of life in elderly patients gains importance. Particularly challenging for orthopaedic surgeons is the treatment of extended acetabular defects. This study examines the clinical and radiological …
-
A tribological investigation into the wear and lifetime prediction of metal on plastic artificial hip implants
… High Molecular Weight Polyethylene (UHMWPE) acetabular cup and a cobalt chromium (CoCr) femoral head. As the patient moves, the femoral head articulates within the acetabular cup. Due to the constant articulation of the harder metal on the softer plastic material, wear of the acetabular cup …
-
Computational testing of patient-specific gait features and pelvic motion effects on the risk of edge contact in total hip replacements
… to the failure of THR is edge contact, where the acetabular cup and the femoral head remain concentric but contact falls partially on the cup's rim. Failures associated with edge contact include rim damage, osteolysis and cup dissociation due to altered in vivo loading and torques. The current …
-
Direct Ink Writing of Porous Titanium Acetabular Cups
Acetabular cups, part of a hip prosthesis that sits against the bone in the hip joint are one of the most important implants in total hip arthroplasty. Acetabular cups are usually made from titanium alloys with high porosity and suitable mechanical properties. Traditionally, acetabular cups have …
-
Torques in total hip replacements
… when there was offset between the head and cup centres of rotation) on THR frictional torques. Increasing the applied medial-lateral (ML) translation, as might occur in a patient when there is a lateral misalignment between the centres of the femoral head and acetabular cup, under 1kN …
-
Component Placement in Hip and Knee Replacement Surgery: Device Development, Imaging and Biomechanics
… developed and tested to improve the accuracy of acetabular cup alignment in hip replacement surgery. An ex vivo study demonstrated the accuracy and feasibility of the device for guiding orientation and depth of the acetabular cup. With respect to knee replacement surgery, preoperative and …
-
Degradation of Cobalt Chrome Molybdenum Hip And Knee Implants in Vivo and in Vitro
… condyles in total knee arthroplasty and for acetabular liners in dual mobility total hip designs. CoCrMo has been phased out of conventional THA designs due to its correlation with adverse effects such as ALTR and ALVAL. It is less understood if the mechanisms (i.e. abrasive wear to the …
-
Orientación de la copa acetabular en cirugía asistida por computador versus técnica convencional en artroplastia de cadera
… technique regarding the orientation of the “acetabular” cup in the hip total arthroplastia. Materials and Methods: Descriptive study comparing two cohorts. The patients that have undergone complete hip replacement at the Santa Clara hospital between August 2008 and December 2009 will be …
-
DEVELOPMENT OF A NEW AND NOVEL TOTAL HIP PROSTHESIS
… that would centralize the femoral head in the acetabular cup and a damping mechanism which would reduce peak impact forces acting on the bone and joint by a mixture of finite element modelling and biomechanical cadaveric experimentation. The preliminary studies showed that our design concept …
-
Correlation of Wear and Mechanics for Subjects having a Metal-on-Polyethylene Total Hip Arthroplasty Measured in vivo
<p>Femoral head separation from the acetabular shell has been recorded, but clinical significance of this phenomenon has not yet been established. The objective of the study was to determine if there is a correlation between femoral head separation (sliding of the femoral head away from the …
-
Biomechanical evaluation of reality-based navigation in total-hip arthroplasty
… such as population wide safe zones for acetabular cup version. Instead surgeons are increasingly targeting a patient-specific joint reconstruction in which patient-specific anatomy informs both surgical technique and joint reconstruction.<br/><br/>The first technical section of this work …
-
Development and Implementation of a Computational Modeling Tool for Evaluation of THA Component Position
… and dislocation of the femoral head within the acetabular cup [3] [4]. Developing a successful computational tool to address this issue includes developing a dynamic model of hip joint, implementing implant sizing suggestion algorithms and computing component alignments. Due to advancement in …
-
A Dexterous Surgical Robotic System for Autonomous Minimally Invasive Orthopaedic Interventions
… pelvic osteolysis (bone degradation) behind the acetabular cup during total hip revision surgery, a dexterous robotic system for autonomous debridement of osteolytic bone lesions in confined spaces is developed. The proposed redundant system comprises a conventional rigid-link robot with a CM …
Page 1 of 2