Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 12 of 12 for “"active air sampling"”.
-
Passive and Active Air Sampling for Residential Exposures to Airborne Organophosphorus Pesticides and Oxygen Analogs ("Oxons") in Central Washington State
… and particulate drift. Initial tests on active air sampling methods found the NIOSH recommended sampling matrix (OVS XAD-2 Resin Tubes) to artificially transform substantial amounts of chlorpyrifos (CPF) to its oxygen analog (CPF-O) in the laboratory (up to 32%) and in the field, leading …
-
Švarių patalpų ir kontroliuojamų aplinkų – biologinės taršos kontrolė /
This bachelor's thesis investigated the level of airborne microbiological contamination in cleanrooms and conducted an antibiotic susceptibility test on bacterial colonies isolated from the air. The relevance of this study stems from the increasing importance of biological contamination control in …
-
Passive sampling for semi-volatile organic chemicals in the atmosphere: theory, calibration, and application
… has contributed to the widespread use of passive air samplers (PASs). Combining theoretical calculations, model simulations, and field and laboratory studies, the research described in this thesis endeavored to address important knowledge gaps that still hamper the confident use of PASs. …
-
Validation of Passive Air Sampling Monitors Onboard United States Navy Submarines
An operating submarine creates a unique air quality mixture of compounds that result from a combination of human metabolism, construction materials, materials brought onboard and compounds created through the interaction of ship systems. A comprehensive study of submarine atmospheres is ongoing …
-
Development, Validation, Uptake Rate Modeling and Field Applications of a New Permeation Passive Sampler
Passive air sampling techniques are an attractive alternative to active air sampling because of the lower costs, simple deployment and retrieval methods, minimum training requirements, no need for power sources, etc.. Because of their advantages, passive samplers are now widely used not only for …
-
Development of Passive Samplers for Measuring Indoor Air Concentrations, and Measurement of Physical and Chemical Properties of Semi-Volatile Organic Compounds
… assessment particularly regarding indoor air. Three new passive air samplers (PAS), namely silicone rubber (polydimethylsiloxane, PDMS), styrene-divinylbenzene copolymer (XAD)-Pocket and XAD-PDMS were calibrated against an active air sampler and compared to the more popular polyurethane …
-
Assessing Occupational Exposure to Flame Retardants and Plasticizers using Silicone Passive Samplers and other Measurement Methods
… methods, including dust collection and active air sampling. The thesis advances the understanding of the use of silicone passive samplers for measuring SVOC exposure in personal exposure monitoring and assessment. Three silicone passive sampler configurations (brooches, wristbands and …
-
Measurement and evaluation of microbial contamination during orthopedic implant surgery
… evaluate contamination pathways, such as direct airborne contamination, indirect contamination via the surgical instruments and endogenously contamination from the patient’s own skin where the incision is going to be. Method: Measurements were performed during ongoing hemiarthroplasty femoral …
-
Hazardous biological agents and the occupational exposure risks thereof in an animal testing facility
… potential HBAs in an animal testing facility. Active and passive biological sampling were performed using both culture-dependent methods, such as active air sampling on agar plates, settle plates, surface swabs, and contact plates and culture-independent methods, including the bioaerosol …
-
APPLICATION OF PASSIVE AIR SAMPLERS FOR ATMOSPHERIC RESEARCH, AND DETERMINATION OF METALS IN TREE RINGS AND MARINE SAPROPEL BY ICP-MS
… of atmospheric mercury (Hg) using passive air samplers (PAS) and studies of trace elements in tree cores and sediment using inductively coupled plasma mass spectrometry (ICP-MS). Mercury is a toxic element that is dispersed globally through the atmosphere. Accurately measuring airborne Hg …
-
Underground mine workers' respiratory exposure to selected gasses after the blasting process in a platinum mine
… gasses was simultaneously sampled by means of active and passive sampling methodologies. Method: Personal exposures to NO, NO2 and NH3 were measured and analysed in accordance with NIOSH methods 6014 and 6015. Along with the active air samplers, respiratory exposure to NO2 and NH3 were measured …
-
Posouzení kontaminace pracovního ovzduší v podniku Gumotex a.s. Břeclav těkavými organickými látkami
Diplomová práce se zabývá posouzením kontaminace vybraného pracovního prostředí firmy Gumotex, a.s. těkavými organickými látkami s využitím pasivního vzorkování. V teoretické části je uveden popis těchto látek a jejich reakce v atmosféře, dále pak praktické využití vybraných látek a jejich účinky …