Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 22 for “"active front end"”.

  1. Modeling and Analysis of Active Front-End Induction Motor Drive for Reactive Power Compensation

    <p>In this thesis, an active front end induction motor drive for reactive power compensation is analyzed. The classical vector control approach for high performance control of an induction motor drive is a well established industry standard today. The same idea of decoupled control is extended to …

    ut-knoxville Repository record for Modeling and Analysis of Active Front-End Induction Motor Drive for Reactive Power Compensation (opens in a new tab)

  2. Investigation of Control Concepts for High-Speed Induction Machine Drives and Grid Side Pulse-Width Modulation Voltage Source Converters

    … drives. However, the 3L-NPC VSC is an attractive topology if drastically increased switching frequencies are required. A detailed comparison between a 2L VSC and a 3L-NPC VSC as the machine side converter of the exemplary high-speed induction machine drive is carried out. Voltage-oriented …

    qucosa-diss

  3. A single three phase variable speed drive with unity power factor

    … topology employs only six switches that form and active front-end rectifier and a four-switch inverter. The active front-end rectifier is the first leg of the three-phase bridge. It not only rectifies the voltage source but it also regulates one of the phases for the motor. The four-switch …

    cape-town Repository record for A single three phase variable speed drive with unity power factor (opens in a new tab)

  4. Grid Frequency Regulation Provided by High Power Motor Drives

    … with wide bandgaps, such as SiC and GaN devices, active front end VSDs are growing in popularity. For this reason, an active front end topology is used for the simulation and emulation of the system. Controls are implemented in the VSD, including DC link voltage, inner and outer current loop, and …

    ut-knoxville Repository record for Grid Frequency Regulation Provided by High Power Motor Drives (opens in a new tab)

  5. High-Efficiency Power Electronic Converters for EV Fast-Charging Stations with Energy Storage

    … the battery energy storage systems (BESSs) with active front end converter provides high efficiency with reasonable power density in a DCFC station. It is also realized that the isolated DC/DC converter interfacing BESS and EV determines the overall efficiency of a DCFC station with a low grid …

    mcmaster Repository record for High-Efficiency Power Electronic Converters for EV Fast-Charging Stations with Energy Storage (opens in a new tab)

  6. Reliability Improvement of Regenerative Cascaded H-bridge (CHB) Medium-Voltage Drive

    … In order to allow fourquadrant operation, an active front end version of the cascaded H-bridge topology has been proposed in literature and recently commercialized. In the field, power converters operates under harsh loading and environmental conditions. The resulting stresses imposed on …

    mcmaster Repository record for Reliability Improvement of Regenerative Cascaded H-bridge (CHB) Medium-Voltage Drive (opens in a new tab)

  7. SHUNT ACTIVE POWER FILTERING FOR SMART APPLIANCES

    Due to the increasing trend towards energy saving of white goods appliances and the commercial viability of power electronic components, there has been an expansion in the use of solid state electronics and variable frequency drive motors in these applications. However, a major drawback of using …

    mcmaster Repository record for SHUNT ACTIVE POWER FILTERING FOR SMART APPLIANCES (opens in a new tab)

  8. Unified Control for the Permanent Magnet Generator and Rectifier System

    … magnet generator (PMG) connected with an active front-end rectifier is very popular in the AC-DC architecture. Especially for certain applications like aircraft and vehicles, power density and efficiency is critical. Since the generator and the rectifier can be controlled simultaneously, …

    vt Repository record for Unified Control for the Permanent Magnet Generator and Rectifier System (opens in a new tab)

  9. Voltage support in open pit mining power systems using electric drill rigs

    … to assess voltage sag depth, duration, and reactive power demand under multiple operational scenarios. Simulation results demonstrate that Active Front End (AFE) drives significantly reduce the severity of voltage sag, improve steady-state voltage profiles, and maintain system stability under …

    chalmers Repository record for Voltage support in open pit mining power systems using electric drill rigs (opens in a new tab)

  10. Voltage support in open pit mining power systems using electric drill rigs

    … to assess voltage sag depth, duration, and reactive power demand under multiple operational scenarios. Simulation results demonstrate that Active Front End (AFE) drives significantly reduce the severity of voltage sag, improve steady-state voltage profiles, and maintain system stability under …

    chalmers Repository record for Voltage support in open pit mining power systems using electric drill rigs (opens in a new tab)

  11. An average modeling approach of hybrid power systems for use in mobile refrigeration applications

    … ac motor drive is discussed. The model is intended to be used for an industry power and energy flow study and eventually for a development of product prototype. Challenges unique to this hybrid application, including the thermal system interface, drive cycle response, and battery management, …

    uiuc Repository record for An average modeling approach of hybrid power systems for use in mobile refrigeration applications (opens in a new tab)

  12. Design and Assessment of a Grid Connected Industrial Full-SiC Converter for 690 V Grids

    … Silizium (Si) - Bauelemente in bestimmten Anwendungen sowie Leistungs- und Frequenzbereichen zu ersetzen. Siliziumkarbid (SiC)-Leistungshalbleiter sind die gegenwärtig am Weitesten entwickelten WBG-Leistungshalbleiter. Dank besonderer Materialeigenschaften zeichnen sich SiC-Leistungshalbleiter …

    qucosa-diss

  13. Design and Control of High Power Density Motor Drive

    … design and improvement of the EMI filter in the active front-end rectifier of the motor drive was introduced in this dissertation. Besides the classical filter design method, the parasitic parameters in the passive filter could also influence the filtering performance. Random PWM could be applied …

    utk-theses Repository record for Design and Control of High Power Density Motor Drive (opens in a new tab)

  14. Estimation Methods for Grid-Voltage Sensorless Control of Converters Equipped with an LCL Filter

    … proposed methods can be applied, for example, in active-front-end rectifiers of motor drives or solar inverters.

    aalto Repository record for Estimation Methods for Grid-Voltage Sensorless Control of Converters Equipped with an LCL Filter (opens in a new tab)

  15. Back to Back Active Power Filter for Multi-Generator Power Architecture with Reduced dc-link Capacitor

    … load. In the early 2000s, a shunt type passive front-end for a shipboard power system was proposed. By shunting the two gensets with 30° phase angle difference, a single phase-shift transformer effectively eliminates 5th and 7th harmonics. It achieves a significant size and weight reduction …

    vt Repository record for Back to Back Active Power Filter for Multi-Generator Power Architecture with Reduced dc-link Capacitor (opens in a new tab)

  16. Form-Factor-Constrained, High Power Density, Extreme Efficiency and Modular Power Converters

    … flexibility and standardization to the end users. The trend of modularization has been seen in photovoltaic inverters, telecommunication power supplies, and recently, HVDC applications. A systematic optimal design approach for modular power converters is developed in this dissertation. …

    vt Repository record for Form-Factor-Constrained, High Power Density, Extreme Efficiency and Modular Power Converters (opens in a new tab)

  17. Multiphase Modular Multilevel Converter Based Drive System for Oil and Gas Recovery in Subsea Applications

    … this thesis, apparently, adopts a trend of using low-rating semiconductor devices to handle medium-/high-voltage levels along the various drive system stages. A trend that is believed, by the author, to become in the near future the foundation of flexible, redundant, and compact …

    poli-torino Repository record for Multiphase Modular Multilevel Converter Based Drive System for Oil and Gas Recovery in Subsea Applications (opens in a new tab)

  18. Photovoltaic Source Simulators for Solar Power Conditioning Systems: Design Optimization, Modeling, and Control

    … The proposed simulator efficiency including the active-front-end rectifier and the converter stages at the maximum power point is 96.4%.

    vt Repository record for Photovoltaic Source Simulators for Solar Power Conditioning Systems: Design Optimization, Modeling, and Control (opens in a new tab)

  19. An Industrial Switched Reluctance Motor Drive: Design, Implementation, and Acoustic Noise Modeling and Reduction

    This thesis presents the design, implementation, and acoustic noise modeling and reduction for an industrial switched reluctance motor drive. Although SRMs offer advantages such as simple construction, fault-tolerant operation, and cost-effective manufacturing, their adoption in various …

    mcmaster Repository record for An Industrial Switched Reluctance Motor Drive: Design, Implementation, and Acoustic Noise Modeling and Reduction (opens in a new tab)

  20. Generalized Average-Current-Mode Control of Single-Phase AC-DC Boost Converters with Power Factor Correction

    … and additional functionality in the form of reactive power control capability in bidirectional converters. These features allow using a relatively low switching frequency and slow-switching power devices such as insulated-gate bipolar transistors (IGBTs) in boost PFC converters, including those …

    vt Repository record for Generalized Average-Current-Mode Control of Single-Phase AC-DC Boost Converters with Power Factor Correction (opens in a new tab)

Page 1 of 2