Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 149 for “"aerodynamic diameter"”.
-
Particle Motion in Flows: Contributions to Airborne Aerosol Measurement
… instrument is designed to sample and measure the aerodynamic diameter of particles in the size range of 1-30 mm. Knowledge of the aerodynamic size of a particle includes the impact of unknown variables such as shape, size and density of a particle. Particles of the same aerodynamic diameter have …
-
Applicability of a Portable Particle Monitor for Measuring TSP and PM10 in the Ambient Environment
… PM10 (particles less than or equal to 10 μm in aerodynamic diameter), as these small particles were found to penetrate and deposit in human respiratory tract, causing adverse health effects. The FRM and FEM sampler designated by the USEPA to monitor PM10 and Total Suspended Particles (TSP) mass …
-
A direct-reading particle sizer (DRPS) with elemental composition analysis
… composition of large inhalable particles with an aerodynamic diameter larger than 20 µm. Aerosols of this size penetrate the upper respiratory system upon inhalation and present surface contamination hazards upon settling. The ability to obtain information on the composition of airborne particles …
-
In-Vitro Analysis of the Respiratory Toxicities of Fossil Fuel Combustion Ashes
… of particulate matter; fine (less than 2.5 μm aerodynamic diameter) particles proved substantially more toxic than coarse (larger than 2.5 μm aerodynamic diameter) particles. Dose-response experiments measuring the toxic effects of the transition metals zinc, vanadium and iron revealed that …
-
Evaluation of a Fluorescence Method for Quantifying Bioaerosol Concentrations on Air Quality Filter Samples
… PM10 in the air. PM2.5 are fine particles with aerodynamic diameter <2.5μm, small enough to reach the deepest parts of the bronchi and lungs. PM10 include PM2.5 and larger particles with aerodynamic diameter of 2.5-10μm. Both PM2.5 and PM10 contain multiple components from multiple sources. …
-
Μελέτη της προσωπικής έκθεσης από αιωρούμενα σωματίδια, των φυσικοχημικών χαρακτηριστικών τους και των πηγών τους σε εσωτερικούς χώρους κατοικιών: διερεύνηση της συνεισφοράς του εξωτερικού περιβάλλοντος και των οικιακών δραστηριοτήτων στα αερολύματα εσωτερικών χώρων
… fine particulate matter (PM2.5, particles with aerodynamic diameter less than 2.5 μm), because of their ability to penetrate deeper into the lungs and cause or trigger respiratory and cardiovascular responses. Coarse particles (PM10-2.5, particles with aerodynamic diameter between 2.5 and 10 μm) …
-
Atmospheric concentrations of organophosphate esters in Delhi, India.
… Atmospheric PM2.5 (particulate matter with an aerodynamic diameter ≤ 2.5 microns) samples were collected from April to November 2009 in downtown Delhi. PM2.5 samples were extracted using pressurized liquid extraction and the extracts were analyzed for twelve OPEs, including TPhP, using gas …
-
Characterisation of particulate matter of traffic origin in Singapore
… exposure to atmospheric ultrafine particles (aerodynamic diameter < 100 nm) may be responsible for cardio-pulmonary problems of those living in urban areas. Thousands of ultrafine particles may present within each cubic centimetre of outdoor air but only accounts for a negligible fraction of …
-
Design of an inhalable aerosol size spectrometer
… restrict particle aspiration into the device to diameters above a specified cut-size. A vertical test chamber was also designed to facilitate aerosol dispersion and experimental evaluation of the PIPS. Two PIPS tubes were tested (1.5 cm and 5 cm) at four face velocities (0.6, 1.35, 2.5 and 3.5 …
-
Aerosolization Studies of Zn-DTPA Using Nebulizers for Decorporation of Internal Radioactive Contamination
… Two evaluation parameters, the mass median aerodynamic diameter (MMAD) and geometric standard deviation (GSD), were used to assess whether the aerosols can reach the lower respiratory tract. The results showed that increasing the filling volume of Zn-DTPA solution would decrease the MMAD and …
-
Pure Insulin Nanoparticle Agglomerates for Pulmonary Delivery
… size, with particles between 1 and 5 microns in aerodynamic diameter being within the respirable range. Insulin nanoparticles were produced by titrating insulin dissolved at low pH to the pI of the native protein, and were then processed into microparticles using solvent displacement. Particle …
-
Assessing levels of cytotoxicity in A549 epithelial lung cells under various exposure to African dust particles
… from their source. Coarse dust particles with aerodynamic diameter less than 10 m (PM10) can enter the mouth and nose and stay in the upper respiratory tract, while fine dust particles with aerodynamic diameter less than 2.5 m (PM2.5) can get deep into the lower respiratory tract causing …
-
Ambient aerosol sampling inlet for flow rates of 100 and 400 l/min
… with particle sizes between 3 and 20 μm AD (aerodynamic diameter). The units show wind independent characteristics over the range of wind speeds tested. The aspiration section of the BSI-100 has greater than 85% penetration for particle sizes ≤ 10 μm AD. The IRI-100, IRI-400, IVI-300 and …
-
Characteristics, transportation and transformation of pollutants in respect to the ambient acidity: case studies: Northern China - Beijing, Southern China - Guizhou province, Kanto plain - Japan
… exist in two size classes; coarse aerosols with aerodynamic diameter dp >2-2.5μm, mechanically generated aerosols, e.g. soil-dust, sea-salt, and fine aerosols with aerodynamic diameter dp<2-2.5μm that are usually secondary formed and combustion derived aerosols
-
AN ASSESSMENT OF LOW-COST SENSOR PERFORMANCE USED IN URBAN TROPICAL ENVIRONMENT
Airborne particulate matter with the aerodynamic diameter size ≤ 2.5µm (PM2.5) is measured by Low-cost sensors (LCS) following the principles of optical method with lesser cost. In this study, the performance and accuracy of LCS (AirBeam) are evaluated against filter sampling, beta attenuation and …
-
Understanding the sources, atmospheric processes, health associations and size distribution of aerosol oxidative potential
… OP^DTT and OP^AA of fine particles (PM2.5, with aerodynamic diameter smaller than 2.5 µm) as part of the Southeastern Center for Air Pollution & Epidemiology (SCAPE) project. Ambient size distributions of water-soluble OP^DTT and OP^AA at an urban and a road-side site collected using …
-
Association Between Air Pollution and Obstructive Sleep Apnea
… indoor particulate matter (PM) ≤2.5 µm in aerodynamic diameter (PM2.5), PM10, and nitrogen dioxide (NO2) estimates exposure on OSA. This dissertation examined the association between exposure to air pollution and OSA in the outdoor and indoor environment using multiple exposure metrics in a …
-
1999 Improved Ammonia Emission Inventory by County in Tennessee
… source of PM2.5 (particulate matter with an aerodynamic diameter less than 2.5um). Due to the increasing concentration of PM2.5 in the atmosphere, the need for improved ammonia emission inventories has become an increasingly important air quality issue. This study produced ammonia emission …
-
A circumferential slot virtual impactor for bioaerosol concentration
… a flow rate of 10 L/min the cutpoint is 2.0 µm aerodynamic diameter (AD) and >90% transmission efficiency was found between 4 mm AD, and 22 µm AD. At the flow rate of 30 L/min the cutpoint is 1.2 mm AD and a >90% transmission efficiency was found between 2 and 10 mm AD. Performance and pressure …
-
Understanding the Mechanisms of Gestational Exposure to Ultrafine Particulate Matter on Placental Development and Dysfunction in a Murine Model
… three categories based upon their size (i.e., aerodynamic diameter): coarse (2.5-10 µm), fine (<2.5 µm), and ultrafine (<0.1 µm). Currently, there is no established regulatory limit or guideline for ultrafine particulate (UFP) exposure. Recent data supports the ability of UFPs to impact the …
Page 1 of 8