Results 1 to 6 of 6 for “"aerosol concentrator"”

  1. Two-stage and Three-stage Virtual Impactor System for Bioaerosol Concentration

    … are two virtual impactors designed for sampling aerosol particles from a dilute environment by separating the aerosol into a fine and a coarse particle fraction. Dust particles in the ambient air may deposit within the virtual impactors and affect their performances. In this study the effect of …

    tamu Repository record for Two-stage and Three-stage Virtual Impactor System for Bioaerosol Concentration (opens in a new tab)

  2. A circumferential slot virtual impactor for bioaerosol concentration

    A virtual impactor aerosol concentrator with a circumferential inlet slot has been built and tested. Circumferential slot virtual impactors (CSVIs) have low pressure losses, similar to linear slot impactors, but without particle losses due to end effects. The CSVI was designed using the results …

    tamu Repository record for A circumferential slot virtual impactor for bioaerosol concentration (opens in a new tab)

  3. A two-stage 100 l/min circumferential slot virtual impactor system for bioaerosol concentration

    … two -stage circumferential slot virtual impactor aerosol concentrator system has been developed that is designed for nominal operational conditions of a 2 μm AD cutpoint, an aerosol inflow to the first stage of 100 L/min and a minor flow rate from the second stage of 1 L/min. Each unit was tested …

    tamu Repository record for A two-stage 100 l/min circumferential slot virtual impactor system for bioaerosol concentration (opens in a new tab)

  4. Design of bioaerosol sampling inlets

    … with a Circumferential Slot Virtual Impactor aerosol concentrator. The inlet displays wind-speed independent characteristics with a penetration above 90% for a nominal particle size of 10 µm AD for all wind speeds. Particles up to 11.5 µm AD are sampled through this inlet with a …

    tamu Repository record for Design of bioaerosol sampling inlets (opens in a new tab)

  5. Development of Sample Collection and Concentration Techniques for Aerosol Measurement using Optical Spectroscopy and Microscopy

    … dissertation, new, compact, hand-held, portable aerosol collectors were developed and evaluated for sample collection and analysis by optical spectroscopies or microscopy with high sensitivity and low detection limits. Firstly, the design and evaluation of a multi-stage focusing nozzle was …

    ohiolink Repository record for Development of Sample Collection and Concentration Techniques for Aerosol Measurement using Optical Spectroscopy and Microscopy (opens in a new tab)

  6. Understanding and optimizing transport of aerosol particles in indoor environments and aerosol concentrators.

    … transportof exhaled particles (human respiratory aerosol), and in advancing methods to appropriately sample bioaerosols, which, while infectious, are in low concentration in the environment. The work in my dissertation is motivated by both developing bioaerosol sampling techniques for improved …

    umn Repository record for Understanding and optimizing transport of aerosol particles in indoor environments and aerosol concentrators. (opens in a new tab)