  1. Characterization of fibrin-targeted microbubbles for detection of peritoneal adhesions

    … acoustic properties relative to soft tissue, an agarose phantom model was developed that allows for high throughput testing of multiple microbubble formulations.

    bu Repository record for Characterization of fibrin-targeted microbubbles for detection of peritoneal adhesions (opens in a new tab)

  2. MICROFABRICATION OF MAGNETIC MICRO-GRIPPERS AND THEIR NAVIGATION USING MRI SYSTEM

    … successfully moved a nickel micro-gripper in an agarose phantom, but the performance was not able to reach our anticipation. Several improvements were hence incorporated in the existing design of micro-grippers. Instead of using nickel, we have used iron as the magnetic layer since iron has …

    jhu Repository record for MICROFABRICATION OF MAGNETIC MICRO-GRIPPERS AND THEIR NAVIGATION USING MRI SYSTEM (opens in a new tab)

  3. Quantification of Localized Brain Iron Sources Using Magnetic Resonance Phase

    … tested in four systems: 1) magnetic resonance agarose phantom and 2) postmortem rat brain, using a ferric iron oxy0hydroxide mimic for hemosiderin, 3) the living rat brain, using collagenase-induced bleeds, and 4) with actual BMB in postmortem cerebral amyloid angiopathy brain. Measurements of …

    loma-linda Repository record for Quantification of Localized Brain Iron Sources Using Magnetic Resonance Phase (opens in a new tab)

  4. Design and Validation of Medical Devices for Photothermally Augmented Treatments

    … diffusion. Bulk infusion into a 0.6% wt agarose phantom was modeled as an infinite, homogenous, and isotropic porous medium saturated with the same solvent used in the infused dye tracer. The source is assumed to be spherical and isotropic with constant flow rate and concentration. The …

    vt Repository record for Design and Validation of Medical Devices for Photothermally Augmented Treatments (opens in a new tab)

  5. Messtechnische, rechnerische und klinische Evaluation der Leistungsfähigkeit der kapazitiven Hyperthermie

    … Im Rahmen dieser Messreihen kommen homogene Agarosephantome aus muskeläquivalentem Material und inhomogene Agarosephantome mit Knochen- und Fettgewebe zum Einsatz. Anhand dieser Modelle werden am kapazitiven System die verschiedenen SAR-Tiefenprofile gemessen. Die vier Messreihen werden mit …

    fu-berlin Repository record for Messtechnische, rechnerische und klinische Evaluation der Leistungsfähigkeit der kapazitiven Hyperthermie (opens in a new tab)