Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 33 for “"air duct"”.
-
Adjoint-based air duct topology optimisation
… apply the software HELYX-Adjoint for creation of ducts for the climate system. HELYX-Adjoint is an adjoint CFD solver that, given an initial geometry, automatically produces an optimal shape. For this purpose, the software was applied on a manifold duct with two outlets. The objective of the …
-
Thermal and Structural Analysis of the Blow Moulded Air Duct
… this study, one of the plastic automotive parts, Air Duct, manufactured through blow moulding process is reviewed and investigated with a practical process point of view using structural mechanics approach. First, current blow moulding process was examined to find governing factors of the process …
-
Hydrodynamic and heat transfer characteristics of a solar heated air duct
Thesis (Ph. D.)--Michigan State University. Dept. of Agricultural Engineering, 1967
-
Life-cycle cost analysis and probabilistic cost estimating in engineering design using an air duct design case study
… energy costs can be reduced considerably if air duct systems are designed for the least life-cycle cost. The IPS-Method, a simple approach to HVAC air duct design is suggested. The Diameter and Enhanced Friction Charts are also developed. These are charts that implicitly incorporate the LCC …
-
Design And Simulation Analysis of a BIPV (Building Integrated With PV) Air-Duct System for Residential High-Performance Development
… are impacted by the thermal resistance of the air duct BIPV because of the change in thermal resistance. Therefore, augmenting the efficiency of (BIPV) devices will benefit many building architectures and mechanical engineering applications. This work introduces a low-cost and low- maintenance …
-
Genom jorden
… and the design, energy simulations have been conducted in Derob where the Swedish passive house requirements have been a guideline. The final model is a building that fulfils the passive house requirements. The model costs 5 % more than a project that has been planed for 2010 by Peab according to …
-
Demand Controlled Ventilation: Use in Calgary and Impact of Sensor Location
… amount of energy required to condition outdoor air introduced into a building based by monitoring occupancy. This thesis reports the hours DCV is used in an existing building in Calgary. Results showed DCV was used approximately 20% of annual fan operating hours when paired with an air-side …
-
Aeolous Innovations: The Sonivent Automated HVAC Heating/Cooling Register
… is set to roll out a simple and effective product to help save customers money each month on their heating and cooling bill. Our product, the Sonivent, is an easy to install, easy to use vent that is able to fit in any home air duct. By closing off the vent to an unoccupied room, a customer is …
-
Effect of configuration variables on performance of solid fuel ramjets.
… performance in the solid fuel ramjet was conducted. The effect of air ducting methods on combustion efficiency was found to be dependent not only on the flow rates, momentum and geometry of the system but also on the composition of the solid fuel. High pressures and low air mass fluxes …
-
Local air leakage measurement and Cfd analysis of deformed ducts in residential HVAC ducts
… is developed to identify and quantify the local air leakage rates in residential HVAC ducts. The technique is based on duct pressurization test (ANSI/ASHRAE standard 152/2004) along with a zone bag to create artificial restrictions. The experiments were conducted at the Air Duct Leakage …
-
Effects of duct source and termination impedance on the acoustic response characteristics of duct elements
… is to study the effects of termination of an air duct on the acoustic response characteristics of the elements in the duct system. The end reflections due to the mis-match of the acoustic impedance at the termination affect the acoustic characteristics of the duct elements; The ducts of the …
-
Dust in ventilation ducts : accumulation, measurement and removal
… in, and removal from, recently installed supply air ducts and on the bristle behaviour of rotating duct cleaning brushes. The results of dust accumulation, measured using three different methods, were compared and the amount of dust in newly installed air ducts was evaluated. The vacuum test was …
-
New Mathematical Models for Acoustic Insertion Loss of Fiberglass Lining in HVAC Duct
The design objectives for HVAC air distribution systems are thermal comfort, good indoor air quality, energy efficiency, low construction cost, and appropriate indoor noise levels. The last objective requires that the designer can predict the attenuation of sound transmitted through an air duct. …
-
Neutronics Simulations of Graphite Experiments
… geometry resulted in 0.222 as the graphite to air ratio. The IM1 experiment required many different configurations to be modeled in MCNP6. In order to further characterize the experiment different boric acid concentrations were poured in a beaker. The boric acid concentration produced an …
-
Protocol for characterizing contaminant emissions during construction activities
… removal, carpet removal/installation, painting, air duct caulking/sealing. Sampling was performed near each activity, at some distance from the activity to estimate spreading potential, and in supply air to determine background concentrations. In addition, ventilation/exhaust rates were measured …
-
The utilisations of engineering solid mechanics and computational fluid dynamics in art and design
… and (3) the practical applications in product and visual design. The combination of NURBS and CFD can accurately and conveniently draw streamlines to reflect original shapes in art and closely analyse existing ones. Raphael's oil painting Jacob's Encounter with Rachel and Ingres' La Source …
-
Local leakage measurement and Cfd prediction of k-factors of leaks in residential HVAC ducts
… in this research focuses on a new technique, Duct pressurization Local Leakage (DPLT) technique, developed to locate leaks in residential HVAC ducts and to quantify their leak rates. The local leakage rate determined by this technique was compared with known leakage from artificial holes. This …
-
Simulation Analysis of a Ventilated Building Integrated Photovoltaic Air-Gap Duct System For Natural Ventilation of a Building
… a low-cost and low-maintenance wind-catcher duct system design addition to BIPV systems that increase airflow velocity and decrease air temperature resulting in increased performance for the PV system electricity output. The results of our work demonstrate the design can further enhance …
-
Dynamic analysis of unevenly sampled data with applications to statistical process control
… data collected from a vibrating warehouse air duct.
Page 1 of 2