Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 8 of 8 for “"air handler"”.

  1. EVALUATION OF LOW FACE VELOCITY WIDE FIN SPACING AIR HANDLERS FOR TROPICAL APPLICATIONS

    The air handler serving Lecture Theatre One of the National University of Singapore was retrofitted with a Low Face Velocity(LFV) unit, with the objective to evaluate its performance in providing good indoor humidity control over different load conditions, without the use of energy intensive means. …

    nus Repository record for EVALUATION OF LOW FACE VELOCITY WIDE FIN SPACING AIR HANDLERS FOR TROPICAL APPLICATIONS (opens in a new tab) Download file for EVALUATION OF LOW FACE VELOCITY WIDE FIN SPACING AIR HANDLERS FOR TROPICAL APPLICATIONS (opens in a new tab)

  2. Computer simulated studies for energy-efficient operation of HVAC equipment

    … of retrofitting heating, ventilating, and air conditions (HVAC) control systems at their Kingston, New York facilities. Steady-state computer simulations of a single-duct air handler, dual-duct air handler and perimeter radiation heating system are developed to compare existing control …

    ut-knoxville Repository record for Computer simulated studies for energy-efficient operation of HVAC equipment (opens in a new tab)

  3. Condition monitoring of high efficiency heating, ventilation and air conditioning systems

    … efficiency in HVAC (Heating, Ventilation and Air conditioning) systems. Energy consumption has increased rapidly in recent decades. This has elevated concerns of a future energy crisis, and heavy negative environmental impacts. An air handler, or air handling unit, is a device used to …

    gatech Repository record for Condition monitoring of high efficiency heating, ventilation and air conditioning systems (opens in a new tab)

  4. A Maximum-Impact Cyber Adversary Design and Impact Evaluation Framework for Network-Based Control Systems in Smart Buildings

    … given to condenser water temperature setpoint, air handler unit’s supply air temperature setpoint, and core zone supply air flow rate setpoint for the studied system.

    tamu Repository record for A Maximum-Impact Cyber Adversary Design and Impact Evaluation Framework for Network-Based Control Systems in Smart Buildings (opens in a new tab)

  5. Thermodynamic and Workload Optimization of Data Center Cooling Infrastructures

    … for new-age infrastructures containing both air- and liquid-cooled servers, one of the critical issues in the DC industry. Exhaust hot water from liquid-cooled servers was used to drive an adsorption chiller, which in turn produced chilled water required for the air-handler units of the …

    mcmaster Repository record for Thermodynamic and Workload Optimization of Data Center Cooling Infrastructures (opens in a new tab)

  6. Performance and Optimization of an Underfloor Air Distribution System in an Educational Building in a Hot and Humid Climate

    … strategies that involve the underfloor air systems combined with Energy Recovery Ventilation (ERV) especially in hot and humid climate. This thesis examines the performance and optimization of underfloor air distribution systems (UFAD) in hot and humid climates. This thesis also compares …

    tamu Repository record for Performance and Optimization of an Underfloor Air Distribution System in an Educational Building in a Hot and Humid Climate (opens in a new tab)

  7. Energetické štítky elektrických spotřebičů

    Ve své bakalářské práci jsem se zabýval energetickými štítky elektrických spotřebičů. Postupoval a řídil jsem se Zákonem č. 406/2000 Sb., o hospodaření energií, který v rámci přípravy ČR na vstup do EU zavádí v souladu s evropskou legislativou. Tento zákon a legislativa s ním spojená, znamená …

    brno-tech Repository record for Energetické štítky elektrických spotřebičů (opens in a new tab)