VARIABLE AIR VOLUME AND CONSTANT AIR VOLUME AIR?CONDITIONING SYSTEMS IN SINGAPORE
… for the VAV system over the CAV (Constant Air Volume) system questionable, and a significant number of building owners are considering or are already in the process of reverting to the CAV system in the air-conditioning design for their new buildings. This report aims at comparing the two …
-
Digital control for an existing variable-air-volume air handling system
… thesis presents the modifications to a variable-air-volume (VAV) system designed to improve the system efficiency. An improved control strategy is applied using direct digital control. The system operates in a medium-size office building (85,000 ft.<sup>2</sup> ) and is used only for cooling. The …
-
A MODELLING STUDY OF VARIABLE AIR-VOLUME FAN COIL UNIT (VAV-FCU)
… by the building function. In particular, air-conditioning equipment must be . capable of meeting the building peak cooling load. Air-conditioning system is the largest single consumer of electrical energy. Office buildings and shopping complexes have a similar electricity consumption …
-
A study of energy usage in a variable air volume HVAC system
… a building often operates using either Constant Air Vo1ume (CAV) system or Variable Air Volume (VAV) system. The CAV system supplies a constant amount of air into each zone by varying the supply air temperature. On the other hand the VAV system operates by responding to each zone's load …
-
Development of Models for Series and Parallel Fan Variable Air Volume Terminal Units
Empirical models of airflow output and power consumption were developed for series and parallel fan powered variable air volume terminal units at typical design pressure conditions. A testing procedure and experimental setup were developed to test sets of terminal units from three different …
-
Dynamic modeling and global optimal operation of multizone variable air volume HVAC systems
… aspects of control of Heating, Ventilating and Air-Conditioning (HVAC) and building systems. The study on optimal operation as well as modeling of HVAC and building systems is one of the fastest growing fields that contribute to saving energy and improving indoor environment. This thesis is …
-
A study on static pressure reset and instability in variable air volume HVAC systems
<p>This project began with testing five different versions of supply duct static pressure reset strategies that fall into two general categories: Proportional plus Integral control loops, and Trim and Respond control strategies. The testing took place from July 2009 through January 2011 at the …
-
A microprocessor data acquisition system for control of a variable-air-volume air conditioning system
… system is used in the modification of a variable-airvolume (vAv) system. This VAv system occupies a medium size four story office building located at the Knoxville Utilities Board Middlebrook Pike site.</p><p>A direct digital control system was installed to control the two cooling coils. Control …
-
Development and Evaluation of High-Performance Rule-Based Sequences of Operation for Variable Air Volume Systems
… percent is used by the heating, ventilation, and air conditioning (HVAC) system. Despite the significant role of the HVAC control systems in energy efficiency, its design, commissioning, and retrofit have long been an intricate and complicated issue, considering that only diffuse and fragmented …
-
Fault Detection and Diagnostics in Single-Duct Multiple-Zone Variable Air Volume Air Handling Unit Systems
Variable air volume (VAV) air handling unit (AHU) systems are the most common heating, ventilation, and air conditioning (HVAC) configuration in North America's commercial buildings. They account for a large fraction of sensors and actuators and are prone to faults due to their control systems' …
-
An investigative analysis of an advanced trim and respond control strategy for variable air volume HVAC systems
… By optimizing fan controls in variable air volume (VAV) HVAC systems, up to 30 to 50% of fan energy can be saved using trim and respond (TR) strategies compared to constant pressure strategies. The tiered trim and respond (TTR) strategy has shown promise in realizing significant fan …
-
Simulation-based study on CO2-based demand controlled ventilation strategies for multiple zone variable air volume systems
… that provides automatic reduction of outdoor air intake below design rates when the actual occupancy of spaces served by the system is less than design occupancy. This research aimed to propose CO2 and occupancy sensor-based DCV for multiple-zone VAV systems and to evaluate the proposed DCV …
-
Analysis of energy, exergy and greenhouse gas emissions for variable air volume systems in an office building
… energy efficiency of Heating, Ventilating and Air-Conditioning (HVAC) systems in commercial buildings and the reduction of their associated environmental impacts are extremely important. Two types of Variable Air Volume (VAV) systems applied to an existing office building in Montreal are …
-
Influence of Channel Geometry and Inflow Hydrograph on Hydraulics and Air Volume Around Shafts of a Stormwater Main
… flow, and how changes in water depth impact air volume and pressure around an air shaft. The study is conducted using CHAN, a one-dimensional model that simulates both flow hydraulics in mains and associated changes in air volume and pressure around air shafts. Main difference between CHAN …
-
Optimized Fan Control In Variable Air Volume HVAC Systems Using Static Pressure Resets: Strategy Selection and Savings Analysis
… (SPR) control to save fan energy in variable air volume HVAC systems has been well documented. Current research has focused on the creation of reset strategies depending on specific system features. As the commissioning process has begun to require the prediction of savings, knowledge of the …
-
Impact of Implementing a Dedicated Outdoor Air System in Parallel with a Multi-Zone Variable-Air Volume System on Energy Consumption, Thermal Comfort, and Life Cycle Cost
Heating, Ventilating, and Air-Conditioning systems (HVAC) consume more than 40% of energy in commercial buildings, according to the Commercial Building Energy Consumption Survey in 2012. Therefore, efforts to reduce HVAC energy consumption would be significant in coping with energy-related issues. …
-
Exchange airflows through doorways induced by door opening and occupant movement
In healthcare settings, patients with infectious airborne diseases are typically placed in negative pressure isolation rooms to reduce the spreading of the infections. Nevertheless, containment failures can still happen, and it has been assessed that the combined effect of door opening and …