Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 265 for “"air-cooling"”

  1. The effects of air cooling on the film blowing process

    … is concerned with the numerical simulation of air-cooling in the film blowing process. In many film blowing production lines, film cooling is the limiting stage in achieving higher productivity. At the same time, the cooling air stream affects the stability and the shaping of the molten bubble, …

    mcmaster Repository record for The effects of air cooling on the film blowing process (opens in a new tab)

  2. Next-generation dedicated outdoor air cooling systems for low-energy buildings

    … consumption in the United States, among which cooling energy comprises an especially significant part in hot and humid climates. To achieve low-energy and low-carbon building communities, it is necessary to design high-performance building enclosures and develop energy-efficient cooling …

    mit Repository record for Next-generation dedicated outdoor air cooling systems for low-energy buildings (opens in a new tab)

  3. A Study of the Operating Characteristics of an Air Cooling System

    … the operating characteristics of a direct air cooling system and to present this information in such a manner that it will meet, in part, the demand for such material.</p> <p>The special ends or determinations to which these tests have been directed are: (1) An investigation of the relation …

    ut-knoxville Repository record for A Study of the Operating Characteristics of an Air Cooling System (opens in a new tab)

  4. A piezoelectric translational flow agitator for active air cooling of electronics.

    … fabrication, the need increases for powerful cooling facilities. Different cooling schemes such as liquid cooling, direct sprays, boiling heat transfer, etc. have been developed to meet the needs of heat removal. Air cooling still has potential for improvement and continues to hold many …

    umn Repository record for A piezoelectric translational flow agitator for active air cooling of electronics. (opens in a new tab)

  5. Reducing Air Compressor Work by Using Inlet Air Cooling and Dehumidification

    Air compressor systems play a large role in modern industry. These compressors can account for a significant portion of a manufacturing facility’s electric consumption and any increase in efficiency can lead to economic benefits. Air compressors are sensitive to ambient conditions, as evidenced by …

    tamu Repository record for Reducing Air Compressor Work by Using Inlet Air Cooling and Dehumidification (opens in a new tab)

  6. RISK ASSESSMENT AND MITIGATION OF TELECOM EQUIPMENT UNDER FREE AIR COOLING CONDITIONS

    … about 40% of the total energy is devoted to the cooling infrastructures in data centers. One way to save energy is free air cooling (FAC), which utilizes the outside air as the primary cooling medium, instead of air conditioning, to reduce the energy consumption to cool the data centers. Despite …

    maryland Repository record for RISK ASSESSMENT AND MITIGATION OF TELECOM EQUIPMENT UNDER FREE AIR COOLING CONDITIONS (opens in a new tab)

  7. Technical, Economic, and Life Cycle Assessment of Membrane-Based Air-Cooling Systems

    The escalating demand for space cooling in Qatar, projected to triple by 2050, underscores the urgent need to shift from traditional refrigerant-based systems to more sustainable air-cooling technologies. This transition aims to mitigate the significant contributions to global warming, with a …

    tamu Repository record for Technical, Economic, and Life Cycle Assessment of Membrane-Based Air-Cooling Systems (opens in a new tab)

  8. COORDINATING LIQUID AND FREE AIR COOLING WITH WORKLOAD ALLOCATION FOR DATA CENTER POWER MINIMIZATION

    Data centers are seeking more efficient cooling techniques to reduce their operating expenses, because cooling can account for 30-40\% of the power consumption of a data center. Recently, liquid cooling has emerged as a promising alternative to traditional air cooling, because it can help eliminate …

    ohiolink Repository record for COORDINATING LIQUID AND FREE AIR COOLING WITH WORKLOAD ALLOCATION FOR DATA CENTER POWER MINIMIZATION (opens in a new tab)

  9. Thermal Behavior and stability study of a lithium-ion battery pack with air cooling

    … térmico de un módulo de baterías refrigerado por aire compuesto de baterías cilíndricas de iones de litio de tipo LiCoO2 (LCO) 26650 (diámetro 26 mm y altura 65 mm). Primero, se evaluó una sola celda comparando tres enfoques: un modelo térmico de parámetros concentrados o resistencia térmica …

    chile Repository record for Thermal Behavior and stability study of a lithium-ion battery pack with air cooling (opens in a new tab)

  10. Techno-economic application of modular air cooling units for deep level mining at Mponeng

    … This then necessitates the need for an effective cooling medium that not only has a great efficiency but should also be sustainable in the current economical environment faced with power supply shortages. Currently the advantages of ice are explored on Mponeng Below 120 level (120L) project with …

    nwu-za Repository record for Techno-economic application of modular air cooling units for deep level mining at Mponeng (opens in a new tab)

  11. Development and analysis of techniques to improve air-cooling and temperature uniformity in battery packs

    … a novel concept has been developed to improve air-cooling and temperature uniformity in a simple battery pack by incorporating inlet plenum, jet inlets, and vortex generators. The proposed battery pack concept reduced the maximum temperature by about 6%. Furthermore, the temperature difference …

    uoit Repository record for Development and analysis of techniques to improve air-cooling and temperature uniformity in battery packs (opens in a new tab)

Page 1 of 14