Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 26 for “"air-distribution system"”.

  1. Non-Iterative Technique for Balancing an Air Distribution System

    Balancing an air distribution system consists primarily of measuring airflow and adjusting volume control devices to get specified airflow. Flow calculation methods are not accurate enough to ensure proper balancing by duct design alone. To assure proper balancing, dampers within an air …

    vt Repository record for Non-Iterative Technique for Balancing an Air Distribution System (opens in a new tab)

  2. The Effect of a Supplemental Air Distribution System on Greenhouse Tomato Production

    <p>The effectiveness of a supplemental internal air distribution system for closed greenhouses with dense plant canopies was evaluated. The system employed centrifugal fans and perforated ducts to move relatively warmer air from above the canopy to within the canopy. Preliminary tests demonstrated …

    ut-knoxville Repository record for The Effect of a Supplemental Air Distribution System on Greenhouse Tomato Production (opens in a new tab)

  3. Field Evaluation of an Underfloor Air Distribution System in an Office Building

    … thermal comfort in an office with an underfloor air distribution system. In an earlier study, thermal stratification, ventilation effectiveness and thermal comfort were evaluated with this arrangement, but diffusers were later relocated away from occupants and furniture. The opportunity was taken …

    calgary Repository record for Field Evaluation of an Underfloor Air Distribution System in an Office Building (opens in a new tab)

  4. Empirical and human response studies of personalized ventilation combined with underfloor air distribution system

    … the use of Personalized Ventilation (PV) system in conjunction with an Under Floor Air Distribution (UFAD) system (PV-UFAD) with focus on improvement of occupants? thermal comfort and inhaled air quality in an energy efficient manner. The problem of ?cold feet? and ?warm head? in …

    nus Repository record for Empirical and human response studies of personalized ventilation combined with underfloor air distribution system (opens in a new tab) Download file for Empirical and human response studies of personalized ventilation combined with underfloor air distribution system (opens in a new tab)

  5. A BIM-Based Approach for Optimizing HVAC Design and Air Distribution System Layouts in Panelized Houses

    In a centralized air distribution system, the designed ductwork layout impacts the system performance and the construction time and cost. Engineers face various challenges, including spatial limitations, leading them to use assumption-based design methods to balance their design with construction …

    concordia Download PDF for A BIM-Based Approach for Optimizing HVAC Design and Air Distribution System Layouts in Panelized Houses (opens in a new tab)

  6. Performance and Optimization of an Underfloor Air Distribution System in an Educational Building in a Hot and Humid Climate

    Today there is a proliferation of different HVAC system configurations. Design and performance of each HVAC system are dependent on climate and the intended use of the building. Energy recovery ventilation is becoming more common in new buildings and is one of the more popular retrofit options in …

    tamu Repository record for Performance and Optimization of an Underfloor Air Distribution System in an Educational Building in a Hot and Humid Climate (opens in a new tab)

  7. The Effects of Diffuser Exit Velocity and Distance Between Supply and Return Apertures on the Efficiency of an Air Distribution System in an Office Space

    The distance between supply air diffusers and return air grilles is an important design parameter that has not been properly investigated. Sometimes, design and installation constraints force the engineer or the contractor to place the return duct close to the supply duct which can have a huge …

    sdstate Repository record for The Effects of Diffuser Exit Velocity and Distance Between Supply and Return Apertures on the Efficiency of an Air Distribution System in an Office Space (opens in a new tab)

  8. Airflow Analysis in Mechanically Ventilated Obstructed Rooms

    … typical room flowrates and inlet types the room air distribution system is obstruction ratio independent. Local velocities and standard deviations varied with each obstruction setup and inlet combination. However, average air velocities and turbulence intensities were not influenced by …

    uiuc Repository record for Airflow Analysis in Mechanically Ventilated Obstructed Rooms (opens in a new tab)

  9. Design of a wind-powered cooling system for an apple storage facility

    … facility, and to design an appropriate energy system. Fruit requirements, wind generator characteristics, and energy storage are discussed. Detail design of a cooling system was performed, including design calculations and equipment specification. The expecting cooling loads for the building …

    vt Repository record for Design of a wind-powered cooling system for an apple storage facility (opens in a new tab)

  10. Mathematical modelling and performance evaluation of compartmented coil for enhanced IAQ and energy efficiency

    … cooling coil of the Single Coil Twin Fan air-conditioning and air distribution system. A fundamental mathematical model has been formulated and validated based on a comprehensive experimental methodology. Efforts have been taken to derive unique boundary conditions for the compartmented …

    nus Repository record for Mathematical modelling and performance evaluation of compartmented coil for enhanced IAQ and energy efficiency (opens in a new tab) Download file for Mathematical modelling and performance evaluation of compartmented coil for enhanced IAQ and energy efficiency (opens in a new tab)

  11. New Mathematical Models for Acoustic Insertion Loss of Fiberglass Lining in HVAC Duct

    The design objectives for HVAC air distribution systems are thermal comfort, good indoor air quality, energy efficiency, low construction cost, and appropriate indoor noise levels. The last objective requires that the designer can predict the attenuation of sound transmitted through an air duct. …

    unlv Repository record for New Mathematical Models for Acoustic Insertion Loss of Fiberglass Lining in HVAC Duct (opens in a new tab) Download PDF for New Mathematical Models for Acoustic Insertion Loss of Fiberglass Lining in HVAC Duct (opens in a new tab)

  12. Energy comparison of under floor air distribution heating ventilation and air conditioning systems in office buildings

    … to compare energy consumption with under floor air distribution systems for office buildings, specifically a call center application.;The building being modeled will have an HVAC system that utilizes an underfloor air distribution system (UFAD). This type of system allows air to be introduced …

    iastate Repository record for Energy comparison of under floor air distribution heating ventilation and air conditioning systems in office buildings (opens in a new tab)

  13. Prevention of compressor hunting in DX rooftop unit through supply air temperature optimization

    … unit (RTU) is typically referred to as a unitary system, which employs direct-expansion (DX) air-condensing equipment for cooling and then provides the conditioned air to the space through dedicated air distribution system. Over the years, the DX RTU has wide applications due to its greater …

    nebraska Repository record for Prevention of compressor hunting in DX rooftop unit through supply air temperature optimization (opens in a new tab)

  14. Experimental study of restrictor noise in ventilation duct systems

    Single-hole restrictors are widely used in the aircraft air distribution system (ADS). The noise generated due to the flow passing over the restrictor is a main interior noise source of the cabin. Prediction of the restrictor noise generation is important for a quite ADS design.<br/><br/>This work …

    soton Download PDF for Experimental study of restrictor noise in ventilation duct systems (opens in a new tab)

  15. Combining a Building Integrated PVT System with a Low Temperature Desiccant Cooler to Drive Affordable Solar Cooling

    … a desiccant/indirect evaporative cooling (IEC) system. In this HVAC system, the PVT array supplies warm air to regenerate the desiccant wheel for cooling purpose or to provide space heating directly to the building, plus the electricity generated. Two building models are investigated, a rooftop …

    unsw Repository record for Combining a Building Integrated PVT System with a Low Temperature Desiccant Cooler to Drive Affordable Solar Cooling (opens in a new tab)

  16. Experimental study on air change effectiveness in mixing ventilation

    … the ultimate purpose of heating, ventilating and air conditioning (HVAC) system. Building ventilation directly affects indoor air quality, and it influences occupant’s heath and productivity. Mixing ventilation is the most common air distribution system, and often the same diffusers provide space …

    texas Repository record for Experimental study on air change effectiveness in mixing ventilation (opens in a new tab)

  17. The Combustion of Low Grade Fuels in Fluidised Bed Combustors

    … considering the coals application in full scale systems. It is not only coal which can be utilised. Further work investigated the effects of five different biomass fuels in FBC. Biomass can be classified as a CO2 neutral fuel as the CO2 released during combustion is relatively equal to the CO2 …

    whiterose Download PDF for The Combustion of Low Grade Fuels in Fluidised Bed Combustors (opens in a new tab)

  18. Soft pneumatic devices for blood circulation improvement

    … actuators, as well as the pneumatic circuits and air distribution system and PLC control patterns will be outlined. The trial run of the devices have been field--‐tested as soon a prototype was ready, so as to tune its features step--‐by--‐ step. I am also giving a characterization of a commercial …

    cagliari Repository record for Soft pneumatic devices for blood circulation improvement (opens in a new tab)

  19. An investigation of the airflow in mushroom growing structures, the development of an improved, three-dimensional solution technique for fluid flow and its evaluation for the modelling of mushroom growing structures

    This thesis is an examination of the airflows in mushroom growing rooms. An experimental investigation of the nature of the flows in Irish tunnels showed them to be of low magnitude at the crop but controllable in principle for single layer growing. It was found that stratification of the airflow …

    dcu Download PDF for An investigation of the airflow in mushroom growing structures, the development of an improved, three-dimensional solution technique for fluid flow and its evaluation for the modelling of mushroom growing structures (opens in a new tab)

Page 1 of 2