Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 42 for “"airtightness"”.
-
Costs and Benefits of Building Airtightness Improvements for Air Pollution Exposure and Human Health
… examines the health impact of enhancing building airtightness, particularly in single-family homes where approximately 75% of the U.S. population resides. This thesis conducts a historical study on modeled daily average PM₂.₅ levels between the years 1980 to 2010 in the United States to examine …
-
Airtightness performance of the building envelope of dwellings in Spain. Characterisation and energy impact of air infiltration
Este trabajo aborda la caracterización de permeabilidad al aire de la envolvente de los edificios residenciales en España. Para ello, se propone una metodología con la que se ha estudiado una muestra representativa de casos, que ha generado una base de datos. El grado de permeabilidad al aire, …
-
Yearly Variations in Airtightness of Detached Wooden Houses: Simulations and Laboratory Measurements to Investigate Causes and Consequences
… buildings. Previous research has shown that the airtightness varies over the year and that buildings can be less airtight during winter months. The aim of this thesis is therefore to investigate possible consequences and causes of variations in airtightness of detached wooden houses. …
-
Characterizing Inter-Zonal Airtightness and its Impact on Indoor Air Quality and Energy Performance in Multi-Unit Residential Buildings
… this dissertation characterized inter-zonal airtightness and air/contaminant transport in MURBs to, (1) provide updated data on the feasibility of performance-based compartmentalization requirements (assuming typical design/construction practices consistent with base-code prescriptive …
-
An innovative airtightness test procedure for separating envelope air leakage from interior partition air leakage in multi-zone buildings
A new airtightness test procedure has been developed for separating exterior envelope air leakage from interior partition leakage, when testing a single zone within a multi- zone building. Historically, envelope leakage from a single zone within a multi-zone building could only be measured if exact …
-
Integrated Evaluation of Airtightness, Acoustics, Thermal Performance, and Life-Cycle Carbon Emissions in Code-Compliant Wood-Framed and Thin-Shell Concrete Dome Residential Structures
… dome built in 2022. The analysis focuses on airtightness, acoustic insulation, passive thermal performance, and life-cycle carbon emissions, including both embodied (cradle-to-gate) and operational energy use. Field-based methods included blower door testing, year-long interior temperature …
-
Developing energy-loss test techniques for large buildings.
… of the document was that a fan pressurisation airtightness performance assessment be made of the completed building envelope. For all non-domestic buildings with a gross floor area of greater than 1000m[2] an air leakage test would be required in accordance with CIBSE TM 23:2000 to prove that …
-
Experimental procedure to evaluate air leakage through different building materials
… were compared in order to assess the airtightness performance and recommend appropriate improvements. This study confirmed that under pressure differentials of 10 to 150 Pa, the air flow regime through rigid building materials is mainly laminar. The research also dealt with the …
-
A study on single blower door methods for multifamily buildings in Montreal
Blower doors are widely used to test the airtightness of detached houses, where whole building depressurization can be achieved with one blower door. However, testing of multifamily buildings is less common, partly because several blower doors are required to depressurize the entire building. This …
-
Design Investigation of Container-based Residential Buildings for Improved Energy and Environmental Performance: Integrated Life Cycle Perspective
… thermal bridging analysis and achieving improved airtightness are excluded from the thesis. However, methods of construction to eliminate thermal bridging effects and ensure continuous insulation and airtightness in container buildings should be covered in future research, to ensure that high …
-
Study on the interaction between CLT structural elements and the Icelandic climate
… of CLT are linked to the moisture behaviour, the airtightness of the elements after wetting and drying cycles, the use or non-use of vapour barrier on the wall assembly, and the air tightness during dimensional changes. Climatic conditions greatly influence the behaviour and applicability of CLT, …
-
Calibration of Hygrothermal Models for In-Situ Modelling and Monitoring for Scalable Retrofit Solutions
… often focuses on enhancing insulation and airtightness. However, increasing airtightness without adequate moisture management can lead to elevated humidity and moisture accumulation within the building envelope. This risk is high when overclad reservoir materials such as masonry or wood, …
-
Performance of modern mechanical and natural ventilation systems in apartment buildings under a changing Nordic climate
… boosting conditions so buildings with high airtightness might encounter significant pressure difference over the envelope. Additionally, analysis of intermittent and continuous nighttime mechanical ventilation long-term operation under humid and cold with microbial pollution showed the …
-
Durability Characterization of a High Performance Building Envelope with Vacuum Insulation Panels and Energy Recovery Ventilation
… tests to evaluate the insulation performance, airtightness, and ventilation effectiveness. The impacts of VIPs and ventilation on durability were discussed, with emphasis on moisture buffering, drying potential, mold growth risk, and VIP aging. The house demonstrated exceptional insulation …
-
Modelling Infiltration of Ambient PM2.5 in Higher Education Buildings: An Institution Building Stock Indoor Air Quality Model for Assessing Exposure Risks
… the impact of increasing the building envelope airtightness (Q50) measure on population exposure. Five buildings from the University of Sheffield (UoS) were selected and modelled in CONTAM and EnergyPlus using available data sources, such as the Estates and Facilities Management (EFM) and local …
-
Ventilation in Adaptive Reuse : Reducing uncertainty in concept-stage decisions
… is acceptable when performance, cleanliness, airtightness, origin and documentation of the ventilation systems can be verified. Applying the screen-align-appraise method to an office-to-residential case enables a large portion of the existing ventilation system to be retained, resulting in …
-
Exploring the Passive House Framework in Cooling-Dominated Climates
… (super-insulation, highly performance glazing, airtightness, and mechanical ventilation with ‘heat’ recovery). It was shown that super-insulation and low-thermal transmission windows could result in energy savings of approximately 30% due to reduced heat transfer. Furthermore, it was shown that …
-
Energy efficiency retrofit and decarbonization of old and historic buildings in California
… Next, increasing the building envelope's airtightness should be considered. In contrast, insulation choices require a careful trade-off between increasing indoor comfort and using less carbon-intensive materials. Also, strategic landscape design should be part of a retrofit program. …
Page 1 of 3