Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 14 of 14 for “"all-ceramic crown"”.

  1. Effect of the interface geometry on the structural integrity of the ceramic crown-tooth complex

    … of the tooth adhesively restored with an all-ceramic crown remains is an unknown parameter especially in relation to the interface geometry (thickness and uniformity). Traditionally, the structural integrity of a restored tooth system (tooth-lute-crown) is tested by laboratory based …

    whiterose Download PDF for Effect of the interface geometry on the structural integrity of the ceramic crown-tooth complex (opens in a new tab)

  2. Comparison of Scanning Accuracy of PVS Impressions of Multiple Tooth Preparations with Different Tapers Using Two Benchtop Scanners: An In-Vitro Study

    Introduction: The all-ceramic-crown manufacturing techniques have evolved significantly since the very first porcelain jacket crown was introduced by Dr. Charles Land in 1903 1. With the advancement in computer-aided design and computer-aided manufacturing (CAD CAM) technologies, along with new …

    buffalo Repository record for Comparison of Scanning Accuracy of PVS Impressions of Multiple Tooth Preparations with Different Tapers Using Two Benchtop Scanners: An In-Vitro Study (opens in a new tab)

  3. Comparison of marginal fit of lithium disilicate crowns fabricated with CAD-CAM technology using conventional impressions and two intra-oral digital scanners.

    … use of digital impression techniques in dental crown fabrication is increasing. It is important these techniques yield prosthesis of equal or better accuracy compared to conventional techniques. This study compared marginal gap size in crowns fabricated by conventional and digital impression …

    louisville Repository record for Comparison of marginal fit of lithium disilicate crowns fabricated with CAD-CAM technology using conventional impressions and two intra-oral digital scanners. (opens in a new tab)

  4. The effect of crown cementation on the marginal fit using a micro-CT measurement technique

    … on the marginal gap of lithium disilicate (LDS) crowns made with digital impression and manufacturing (DD), digital impression and traditional pressed manufacturing (DP) and traditional impression and manufacturing (TP). Methods: Ivorine typodont tooth #15 was prepared for an all-ceramic crown. …

    ubc Repository record for The effect of crown cementation on the marginal fit using a micro-CT measurement technique (opens in a new tab) Download PDF for The effect of crown cementation on the marginal fit using a micro-CT measurement technique (opens in a new tab)

  5. Capacity Of The 3M True Definition Scanner To Make Repeatable Impressions Depending On Placement Of Margins In Relation To Gingival Height.

    … teeth was used. Tooth #19 was prepared to fit an all-ceramic crown with a chamfer margin. Spacers placed beneath the prepared tooth elevated #19 in the typodont and controlled the tooth margin height relative to the gingival margin. The TDS was used as an intraoral scanner. A total of 50 scans …

    uab Repository record for Capacity Of The 3M True Definition Scanner To Make Repeatable Impressions Depending On Placement Of Margins In Relation To Gingival Height. (opens in a new tab)

  6. Mechanical Properties of Ceramic Based Functionally Graded Dental Crowns Produced by Additive Manufacturing

    All-ceramic dental crowns present a higher incidence of fracture and chipping when supported by dental implants as opposed to natural teeth. This study attempted to replicate the graded structural design of a natural tooth in an implant-supported all-ceramic crown to improve its fracture resistance …

    tamu Repository record for Mechanical Properties of Ceramic Based Functionally Graded Dental Crowns Produced by Additive Manufacturing (opens in a new tab)

  7. Klinische Untersuchung zur Bewährung von Procera AllCeram-Kronen

    … Im Rahmen dieser Untersuchung wurden 99 Procera AllCeram- Kronen bei 44 Patienten klinisch untersucht. Dabei handelte es sich um 27 Frauen und 17 Männer. Der Zeitraum der Kronen in situ betrug durchschnittlich 52 Monate. Dieses entspricht 4,2 Jahren in Funktion. Von den untersuchten Procera …

    fu-berlin Repository record for Klinische Untersuchung zur Bewährung von Procera AllCeram-Kronen (opens in a new tab)

  8. Marginal gap and internal fit of CEREC e.max and Celtra Duo crowns

    … chipping of e.max (EM) and Celtra Duo (CD) all-ceramic crowns fabricated using chairside economical restoration of esthetic ceramics (CEREC) system. Material and Methods: Tooth # 15 was prepared for an all-ceramic crown on an ivorine typodont. A total of 15 CD and 15 EM crowns were designed …

    ubc Repository record for Marginal gap and internal fit of CEREC e.max and Celtra Duo crowns (opens in a new tab) Download PDF for Marginal gap and internal fit of CEREC e.max and Celtra Duo crowns (opens in a new tab)

  9. Accuracy and Precision of Die Spacer Thickness with Combined Computer-Aided Design and 3-D Printing Technology

    … maxillary central incisor was prepared for an all ceramic crown. The prepared tooth was duplicated by using poly (vinyl siloxane) duplicating silicone and 80 die-stone models were produced using type IV dental stone. Dies were randomly divided into 5 groups with assigned die spacer thickness of …

    marquette Repository record for Accuracy and Precision of Die Spacer Thickness with Combined Computer-Aided Design and 3-D Printing Technology (opens in a new tab)

  10. Reliability and failure modes of anterior zirconium-oxide crowns dependent on coping design

    … propagation of the corresponding anterior all-ceramic crown. Materials and methods: One group consisted of 18 crowns with a constant zirconia coping thickness of 0.5 mm (group S). The other group included 18 crowns with an anatomically designed zirconia coping (increased incisal and …

    freiburg-diss Repository record for Reliability and failure modes of anterior zirconium-oxide crowns dependent on coping design (opens in a new tab)

  11. Glasfaserverstärkte Kompositstifte zur postendodontischen Rekonstruktion oberer mittlerer Schneidezähne mit Vollkeramikkronen

    In dieser In-vitro-Studie wurden die Belastbarkeit und das Frakturverhalten von endodontisch behandelten oberen mittleren Frontzähnen nach adhäsivem Aufbau mit konfektionierten Aufbaustiften, Kompositaufbauten und Vollkeramikkronen in Abhängigkeit vom Stiftmaterial und der Belastungsmethode …

    fu-berlin Repository record for Glasfaserverstärkte Kompositstifte zur postendodontischen Rekonstruktion oberer mittlerer Schneidezähne mit Vollkeramikkronen (opens in a new tab)

  12. Accuracy of Intraoral Scanners with Different Total Occlusal Convergence Angles: An In-Vitro Study

    … one anterior and one posterior complete coverage all-ceramic tooth preparations. A second objective was to evaluate the influence of location of tooth preparation relative to the arch position (anterior v. posterior). This study was performed on a printed poly(ethyl methacrylate)(PEMA) model of an …

    loma-linda Repository record for Accuracy of Intraoral Scanners with Different Total Occlusal Convergence Angles: An In-Vitro Study (opens in a new tab)

  13. Endodontic access in all-ceramic dental restorative crown materials

    … of irreversible pulpitis can occur after a crown has been permanently cemented. This necessitates the need for endodontic treatment, often with the crown in situ. Increasing trends indicate that all-ceramic crowns are provided as the preferred restorative option to metal-ceramic crowns. This …

    cork Repository record for Endodontic access in all-ceramic dental restorative crown materials (opens in a new tab)