Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 27 for “"allan variance"”.
-
Analysis of environment coupled noise terms in inertial sensor data using Allan Variance
… sensor data is commonly measured by using Allan Variance as a method of analysis. Allan Variance (AVAR) is the two-sample variance, originally developed to measure stability in oscillators. Plotting the AVAR curve for inertial sensor data that is mounted on a mechanically stable platform …
-
Advancing widefield nanodiamond biological sensing with CMOS detection
… affect measurement stability within the system, Allan Variance was used to assess fluorescence stability in each imaging modality for frame integration time, camera gain, and laser power, using fluorescent microspheres. Using these fluorescent microspheres, the fluorescent stability of …
-
System development for characterisation of high precision frequency standards performance for radio astronomy and industrial applications
… of the behaviour of these oscillators. The Allan variance is a well-known means to characterise frequency oscillators and clocks, especially for those measurement instruments of ultra-high precision. By taking advantage of the rapid application development approach, a system has been …
-
Stability analysis of a 243 GHz direct detection radiometer
… This evaluation was done by analysing the Allan variance of the system, and finding the receiver temperature with a Y-factor measurement. The intended use of the radiometer was also replicated, by measuring an unknown temperature, along with calibrations against a hot and a cold load. The …
-
Characterization of the clock in a new inexpensive GPS receiver: the Magnavox MX4200
… the receiver clock has been characterized by the Allan variance for sampling intervals up to 4000 seconds. The implication of the noise levels for short time intervals on the applicability of the receiver to high precision work is examined.
-
Analysis of the characteristics of grace dual one-way ranging system
… of the DOWR observation was derived and the Allan variance was computed to establish an upper bound on the level of frequency instability of the ultra-stable oscillators (USO) to determine their contribution to the high-frequency noise. Because they are dominated by the high-frequency noise, …
-
A FAULT TOLERANT, DATA FUSION SYSTEM FOR NAVIGATION APPLICATIONS TO A DUCTED FAN VTOL UAV
… Firstly, system identification and the Allan Variance method is used to build dynamic models and noise models for multiple Sensors and Actuators. Secondly, a GD filter is developed for application to the Inertial Measurement Unit (IMU) consisting of tri-axis gyroscopes, accelerometers …
-
Gyroless Nanosatellite Attitude Determination Using an Array of Spatially Distributed Accelerometers
… model was developed and validated using Root Allan Variance, and the Virtual Gyroscope was tested both in the open loop configuration and as a replacement for a gyroscope in a Multiplicative Extended Kalman Filter. It was found that the quality of the Virtual Gyroscope’s rate measurement …
-
Is Nubia Plate Rigid? A Geodetic Study of the Relative Motion of Different Cratonic Areas within Africa.
… and rate uncertainties computed using the Allan variance of rate (AVR) technique, accounting for colored noise. Although geological and geophysical studies indicate the possibility of internal deformation within Nubia, the results of this study shows that the current GPS network is not …
-
Degree-per-hour mode-matched micromachined silicon vibratory gyroscopes
… Experimental data indicates sub-5 deg/hr Allan deviation bias instability operating under a mode-matched operating Q of 30,000 at 23ºC (in vacuum). The second micromachined silicon vibratory gyroscope presented in this work is the mode-matched tuning fork gyroscope (M2-TFG): a novel …
-
Ground-based attitude determination and gyro calibration
… the star tracker. Power Spectral Density and the Allan Variance Method are used for analyzing the gyro random noises in both ICESat and simulated gyro data, which provide better information about the process noise covariance in the attitude filter. Both simulated and real data are used for …
-
Research on Key Technology of Low-Cost GNSS Receiver in Harsh Environment
… Kalman filter (EKF) with the dual adaptive covariance matrices. It has achieved the higher tracking sensitivity and the lower tracking error. Secondly, in terms of the signal fading caused by the various blockages on the ground, two vector tracking algorithms are investigated to improve the …
-
Development of a methane cavity ring-down spectrometer for deployment on ground and aerial based vehicles
… commercial analyzer showed good 1:1 agreement. Allan variance studies within laboratory measurements demonstrated the sensor's high sensitivity of ~10 ppb. A heater system was designed and implemented for overall improvement in low temperature conditions. The heater system successfully improved …
-
Detection of Aerosols via Coalescence Capture
… As part of the sensitivity analysis, using an Allan variance analysis, the components of noise in an AOT dataset were characterised and the optimal sampling time of 40 seconds per spectra was<br/>determined, and the recommended probe droplet size range was 4 – 5 micrometres. …
-
Silicon-Based Resonant Microsensor Platform for Chemical and Biological Applications
… Short-term frequency stabilities obtained from Allan-variance measurements with 1-sec gate time are as low as 1.1 10-8 in air and 2.3 10-6 in water. The performance of the designed resonator as a biological sensor in liquid environment has been demonstrated experimentally using the specific …
-
Heterodyne Arrays for Terahertz Astronomy
… which is ~7 times the quantum noise limit and an Allan variance time of 15 seconds at an effective noise fluctuation bandwidth of 18 MHz. Heterodyne performance is confirmed by measuring a methanol line spectrum. By combining knowledge of large array formats from SuperCam and quasi-optical mixers, …
-
Development of mobile open-path cavity ring-down spectrometer for measurement of trace atmospheric methane gas
… at a rate of 1-3 Hz. Sensitivity studies using Allan variance techniques show sensitivity of < 20 ppbv in 1 – adequate for practical leak detection of small plumes <1 ppmv. Comparisons against a commercially available closed path sensor in mobile deployments are presented, along with mobile …
-
Applications of optical-feedback cavity-enhanced absorption spectroscopy
… The temporal stability was investigated by Allan variance calculations and the best minimum detectable concentrations for the linear QCL OF-CEAS instrument were 32 ppm for N 2 O (35 s) and 5 ppb for NO (2 s). For NO, this detection limit compares favourably with other mid-IR QCL-based NO …
-
Navigation Sensor Stochastic Error Modeling and Nonlinear Estimation for Low-Cost Land Vehicle Navigation
… GMWM framework and the Average Wavelet Variance (AWV) estimator, which encompasses two robustness levels: one for protection against outliers in each considered replicate and one to safeguard the estimation against the collection of signal replicates with significantly different …
-
Non-linear Error Modeling for MEMS-based IMUs
… variation using two different approaches, namely Allan Variance (AV) and Generalized Method of Wavelet Moments (GMWM), are investigated. Advantages and limitations of each method concerning the ability to 1) identify the latent random processes associated with the detected error model and 2) …
Page 1 of 2