Results 1 to 20 of 162 for “"ambient vibration"”
-
Ambient Vibration Energy Harvesting
… ten years, there has been many research works in vibration-based energy harvesting, i.e., converting ambient vibration sources into electrical energy via different transduction methods. In dealing with environmental vibration sources, the most pressing issue for vibration-based energy harvesters …
-
Ambient vibration testing of concrete dams
… analysis (CVA)) have been applied to data from ambient vibration testing of two concrete dams namely; Roode Elsberg and Kouga dams.
-
Ambient vibration assessment of Ruskin Dam dynamic properties
… instance, seismic resistance. The suitability of ambient vibration testing and analysis to provide meaningful dynamic properties of a concrete gravity dam has been studied. Tests were conducted at B.C. Hydro's Ruskin Dam, located near Mission, B.C. Tests were completed at two reservoir levels to …
-
Automation in ambient vibration analysis for soil characterisation
… the choice of methods. In this case the passive ambient vibration Horizontal-to-Vertical Spectral Ratio (HVSR) method and Evolutionary Algorithms are chosen. The challenges associated with the HVSR method are identified here as the Algorithm Selection Problem and objective function manipulation. …
-
Micro electret power generator for ambient vibration energy harvesting
Ambient vibration sources are commonly available in abundance and characterized by low-level vibration of low frequency (<100Hz) and small acceleration (<0.1g). Vibration energy harvested from ambient environment offers a promising sustainable alternative or complementary source of power for …
-
Geotechnical characterisation of compacted ground by passive ambient vibration techniques
… low cost, efficient and non-invasive passive ambient vibration (or microtremor) based method, which will be calibrated against in situ test data. The simplicity of the HVSR technique is manifested in having a short setup time (relative to other methods), and precluding the need for any active …
-
Ambient vibration analysis of a full-scale hyperbolic cooling tower
Call number: LD2668 .T4 CE 1987 H44
-
Ambient vibration analysis of a full-scale hyperbolic cooling tower
Call number: LD2668 .T4 CE 1987 H44
-
Field investigation of fundamental frequency of bridges using ambient vibration measurements
… dynamique de la structure à travers ses modes de vibration : les fréquences naturelles, la forme des modes et le facteur d'amortissement. Une estimation efficace des paramètres modaux des ponts permet alors une meilleure évaluation, et donc un meilleur suivi, de leur intégrité structurale. …
-
Seismic evaluation of Portage Creek Bridge based on ambient vibration testing
… British Columbia, and as part of this goal, an ambient vibration test was carried out on the bridge in September 2014 in order to update/calibrate the finite element model of the bridge in SAP2000. The updated model was then used to assess the seismic performance of the bridge in accordance with …
-
Characterization of dynamic properties of transmission towers using ambient vibration measurements (AVM)
Ambient vibration measurements (AVM) are sometimes used to characterize dynamic properties of different structures or soils in a non-intrusive and affordable manner. The use of AVM on transmission towers supporting high voltage power lines is not extensively elaborated in the literature. The line …
-
Estimation of Cable Forces at the Ashton Bridge through Ambient Vibration Testing
… of the structure. Superstructure and cable vibration data was collected on site after the final stage of cable tensioning. Finite element models of each cable were created using the software, Sofistik. Thereafter, the force in the cable models was iterated until the theoretical natural …
-
Model updating of a 48-storey building in Vancouver using ambient vibration measurements
… use of tuned liquid column dampers to reduce vibrations due to wind. The "true" dynamic response of the One Wall Centre is of great interest to structural engineers because of the unusual elliptical shape of the concrete shear core, which could present a challenge for modelling. Ambient …
-
Effect of potential shape and excitation spectrum on power harvested from ambient vibration
… developments in energy harvesting from ambient vibrations in small-scale sensing. The ultimate goal is to replace batteries in these sensors. Linear systems have a narrow bandwidth, but ambient vibrations occur over a potentially broad range of frequencies. Nonlinear systems-in …
-
Structural performance evaluation of concrete arch dams using ambient vibration monitoring and GNNS systems
Societies around the world are heavily dependent on civil engineering infrastructures such as concrete dams that provide necessities such as water supply for irrigation, hydroelectric power generation and prevention of floods. As a result, it is important to ensure that concrete dams are protected …
-
Validation of seismic response prediction of a guyed telecommunication mast with ambient vibration measurements
… Québec. Cette étude procède par mesures de vibrations ambiantes (ou bruit ambiant) le long du mât et des câbles de haubans. Ces enregistrements ont ensuite été analysés pour en extraire les caractéristiques dynamiques telles les fréquences naturelles dominantes et les modes de vibration …
-
Dynamic characteristics of a 30 storey building during construction detected from ambient vibration measurements
… characteristics were determined by analyzing ambient vibrations of the structure. These vibrations were acquired and processed using a testing system developed at the University of British Columbia (Department of Civil Engineering). Several computer programs were developed during this project …
-
Seismic site characterization using broadband and DAS ambient vibration measurements on Mt Etna, Italy
… tools to gain insight into local site effects by ambient noise measurements. Here, the two methods are employed to assess the subsurface velocity structure at the Piano delle Concazze area on Mt Etna. Volcanic tremor records from an array of 26 broadband seismometers is processed and a strong …
-
Characterizing soil and structural dynamic behaviour using ambient vibration techniques for earthquake hazard assessment
… in shaking amplification in southwest Yukon. Ambient vibration (AV) methods, which utilize microtremor noise measurements, are employed to identify vibrational modes for both applications by quantifying the behaviour of the building and soils. This research is useful for estimating building …
-
Determination of structural dynamic properties of three buildings in Vancouver, B.C., from ambient vibration surveys
… buildings have been obtained by means of ambient vibration surveys. The buildings surveyed include an asymmetrical hi-rise - the Harbour Centre, and two frame structures -Toronto Dominion Bank and IBM Towers. Three hi-rise buildings of identical design - the Gage Residences - were also …