Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 21 for “"americium-241"”
-
Advances in Americium-241 processing
… 80 years ago by Glenn Seaborg \emph{et. al.}, Americium-241 (\ce{^{241}Am}) has found its way into household and industrial applications ranging from smoke detectors to well logging. Although \ce{^{241}Am} continues to grow in demand, US production stopped \emph{circa} 1984 causing stockpiles …
-
Americium-241 and trace elements in peat bogs as markers of the beginning of the Anthropocene
… Specifically, it examines the potential of the Americium-241, as a potential global stratigraphic indicator for the Anthropocene. Furthermore, this study investigates the stability of 241Am and TEs preservation in peat bogs over time. Three interconnected studies address these objectives by …
-
Anion effects on the retention of selected actinides on geologic media
The distribution coefficients of americium-241 and neptunium-235 were measured on several minerals in synthetic groundwater and NaCl solutions. The minerals studied contain complexing anions within their crystalline lattices, and they were characterized for purity, ion exchange capacity, and …
-
Modeling the Radiation Shielding Effectiveness of Hafnium Diboride Reinforced Epoxy Composites Using MCNP
… from a 152Eu source, and neutrons from an Americium-241/Beryllium source. It was then used in simulations of combined gamma/neutron emitters: an Americium-241/Lithium research source, and Plutonium-238 Dioxide inside a housing for use in a Radioisotope Thermoelectric Generator. Overall, the …
-
A study of the apparent solubilities in water of Americum dioxide and Europium sesquioxide
<p>The apparent solubilities of americium-241 dioxide and americium-243 dioxide in distilled water were measured. In order to obtain a preliminary estimate of the solubility, and to check the experimental procedure, the most common oxide form of the corresponding lanthanide, europium sesquioxide, …
-
Η ΕΠΙΔΡΑΣΗ ΤΩΝ ΓΕΝΙΚΩΝ ΑΝΑΙΣΘΗΤΙΚΩΝ (ΑΛΚΟΟΛΩΝ) ΣΤΟ ΔΥΝΑΜΙΚΟ ΕΠΙΦΑΝΕΙΑΣ ΤΗΣ ΛΙΠΙΔΙΚΗΣ ΜΟΝΟΣΤΙΒΑΔΑΣ ΜΕ Η ΧΩΡΙΣ ΠΡΟΣΘΗΚΗ ΑΝΑΛΗΠΤΙΚΩΝ
… SURFACE POTENTIAL CHANGES WERE MEASURED WITH AN AMERICIUM-241 AIR ELECTRODE CONNECTED TO THE HIGH IMPEDENCE INPUT OF A KEITHLEY ELECTROMETER. THE LOW IMPEDENCE INPUT WAS CONNECTED TO A CALOMEL REFERENCE ELECTRODE. WHEN ALCOHOLS WERE ADDED A NEGATIVE GOING CHANGE IN THE INTERFACIAL POTENTIAL WAS …
-
Thickness measurement of ammonia targets used in SLAC E143 experiment
… were frozen ammonia crystals. A 40 mCurie americium 241 source was used to pass a imated beam of known intensity x-rays through the samples. The x-ray intensity on the other side was measured by a silicon 1 detector. The ammonia material was removed and the process repeated. By comparing …
-
Projeto e construção de um amplificador para espectrometria Gama
… with the radiation sources of cesium-137, americium-241, barium-133 and europium-152 using a sodium iodide detector (NaI (Tl)). The results showed that the amplifier can be used in developing other types of detectors such as proportional and gas. It was found, and also that the spectra …
-
Accident dosimetry using panasonic dosimeters
… and polyethylene- moderated californium-252 and americium-241/beryllium are used to obtain some spectral information from any unknown spectrum.</p> <p>Since accident dosimetry involves extremely high doses, the element responses have been tested for linearity from one to one thousand rad with …
-
Semiconductor Nuclear Detectors
… tested under a radiation flux of α paticles from Americium 241 and Plutonium 239. The results show that the surface barrier detectors fabricated from a p-type substrate had excellent resolution in relation with the detectors from an n-type substrate. Comparing these two types of detectors with the …
-
Characterization of the Neutron Irradiation System for use in the Low-Dose-Rate Irradiation Facility at Sandia National Laboratories
… the neutron irradiation system consisting of americium 241 beryllium (241AmBe) neutron sources placed in a polyethylene shielding for use at Sandia National Laboratories (SNL) Low Dose Rate Irradiation Facility (LDRIF). With a total activity of 0.3 TBq (9 Ci), the source consisted of three …
-
Novel MOS-Based Biomolecule Detection Techniques
… acid (DOTA)-DNA conjugates were used to chelate americium-241 from solution, and the alpha particle emissions over the surface of the IC measured. The IC was able to quantitatively determine the amount of alpha emitter present over each cell, allowing the chelator and chelating chemistry to be …
-
Inherent Electric Field Measurements of Liquid Surfaces using Ionizing Surface Potential
… solvents alike. The ISPS consists of a custom americium-241 (Am-241) ionizing working electrode that is suspended a few millimeters in the air over a liquid sample, within which a platinum gauze reference electrode is submerged. Alpha particles emitted from the active area of the Am-241 ionize …
-
Thermal Simulation for the Proposed DAYBREAK Deep-Space Probe at End of Mission
… is also a testbed case for the utilization of Americium-241 Radioiso-tope Thermoelectric Generators (RTG), a proposed replacement for Plutonium-238 RTGs in theface of dwindling fuel supplies. Am-241 RTGs are much less powerful than Pu-238 RTGs, whichresults in a much smaller power budget …
-
Study of Radiation Tolerant Storage Cells for Digital Systems
… out at the University of Saskatchewan using an Americium-241 alpha source. Heavy ion experiments were performed at the Texas A&M University Cyclotron Institute, utilizing Ne, Ar, Cu, and Ag in a 15 MeV/amu cocktail. Lastly, TID experiments were conducted using a Gammacell 220 Co-60 chamber at …
-
Design and Development of Fission/Fusion Rocket Propulsion System
… analyze particle motion and confinement. Using Americium-241 (²⁴¹Am) and Thorium-232 (²³²Th) sources in an aluminum vacuum chamber, we performed simulations and experiments to measure alpha particle flux, transport behavior, and periodic refocusing effects governed by the transverse cyclotron …
-
Management of the UK plutonium stockpile using thorium fuelled Light Water Reactors
… feasibility of this approach. The build-up of americium-241 from decay of Pu-241 leads to increased fissile feed requirements which, in the case of U-Pu MOX fuels causes the Void Coefficient (VC) to become positive under transient conditions for a stockpile averaged Pu vector from the year 2055 …
-
Determination of Activity Deposited in the Axillary Lymph Nodes by Direct, In vivo Radiation Measurements
… Determine the confounding influence of <sup>241</sup>Am deposited in organs adjacent to the axillary lymph nodes by simultaneous solution of response functions for measurement of <sup>241</sup>Am deposited in the liver, lungs, and skeleton.</i><p>Hypothesis: A series of direct, organ-specific …
-
Tiefenverteilung von Radionukliden in Fichtenwald- und Hochmoorböden
In der Umwelt vorkommende Radionuklide wurden als Tracer für Migrationsverhalten verwendet. Low-level-γ-Spektrometrie und zusätzliche Plutoniumanalysen ermöglichten den Nachweis sehr geringer Konzentrationen radioaktiver Nuklide. Der atmosphärische Eintrag wurde über Regenwasser- und …
-
Determination of actinide elements in environmental samples by ICP-MS
… actinide elements neptunium, plutonium and americium, resulted in the successful determination of 239Pu and 237Np in biological reference materials. Detection limits were 700, 850, and 600 attograms (ag) for 237Np, 233Pu, and 241Am, respectively, for a 0.5 ml sample injection, and better …
Page 1 of 2