  1. A Dynamic Ampacity Model for the Testing of Advanced Conductors

    … The control outlined will make use of an ampacity model capable of accurately describing the current – temperature relationship of bare overhead conductor at an outdoor facility. This model will be used to maintain test conductors at specific elevated temperatures for extended periods of …

    ut-knoxville Repository record for A Dynamic Ampacity Model for the Testing of Advanced Conductors (opens in a new tab)

  2. Underground cable ampacity: a fresh look at addressing the future electric grid

    … addresses underground electric power cable ampacity and provides analytical, experimental, and operational test results for underground cables. The motivation for this work stems from challenges facing the industry in determining cable ampacity due to the uncertainty in soil thermal …

    colo-mines Repository record for Underground cable ampacity: a fresh look at addressing the future electric grid (opens in a new tab)

  3. Configuration Optimization of Underground Cables inside a Large Magnetic Steel Casing for Best Ampacity

    … cylindrical steel casing, from the total ampacity point of view. The method is comprised of two main parts, namely: 1) analytically calculating the electromagnetic losses in the steel casing and sheathed cables, for an arbitrary cables configuration, and 2) implementing an algorithm for …

    toronto-retro Repository record for Configuration Optimization of Underground Cables inside a Large Magnetic Steel Casing for Best Ampacity (opens in a new tab)

  4. DETERMINATION OF TRANSMISSION LINE AMPACITIES BY PROBABILITY AND NUMERICAL METHODS

    … by the conductor is designated as the conductor ampacity and is normally determined from a single set of weather conditions. In recent years, it has been suggested that traditional ampacities are conservative and that local weather and operating practices should be utilized in evaluating a given …

    sask Repository record for DETERMINATION OF TRANSMISSION LINE AMPACITIES BY PROBABILITY AND NUMERICAL METHODS (opens in a new tab)

  5. Aplicação do conceito de cargas cíclicas para dimensionamento de condutores em usinas fotovoltaicas

    … in duct method) involves the criteria of cable ampacity, which evaluates the cable ampacity according to the installation method and its characteristics. The selection of an optimized cable size is made by applying correction factors for soil temperature, cable grouping and soil thermal …

    brazil-ufrn Repository record for Aplicação do conceito de cargas cíclicas para dimensionamento de condutores em usinas fotovoltaicas (opens in a new tab)

  6. Environmental controls on the operating temperature of marine power cables

    … operating temperatures) and reduce costs. The ampacity rating limits the maximum current that can be safely carried, such that the operating conductor temperature is limited to 90°C for Alternating Current (AC) (Worzky, 2009) or 70°C for Direct Current (DC) (Brakelmann & Anders, 2018). Standard …

    soton Download PDF for Environmental controls on the operating temperature of marine power cables (opens in a new tab)

  7. Numerical weather prediction for electrical transmission lines

    … electrical current for safe transmission (ampacity) must be estimated from wind speed, direction, temperature, insolation, and maximum conductor temperature. Power utilities apply this thermal rating to all powerlines. Traditional thermal rating methods do not monitor the weather …

    ubc Repository record for Numerical weather prediction for electrical transmission lines (opens in a new tab) Download PDF for Numerical weather prediction for electrical transmission lines (opens in a new tab)

  8. Study of Cables in the Distribution System: Parameters Calculation, Fault Analysis, and Configuration Optimization

    … of cables in a ductbank based on the total ampacity value. When faults occur in the underground cable system, three aspects need to be analyzed: firstly, the magnetic force waveforms of cables during different types of faults; secondly, the relationship between two types of faults, namely …

    clemson Repository record for Study of Cables in the Distribution System: Parameters Calculation, Fault Analysis, and Configuration Optimization (opens in a new tab)

  9. Characterization of Copper Covetic Bulk and Films: Copper with High Carbon Content

    … in carbon nanostructures that give rise to high ampacity and high conductivity, respectively. Carbon in copper has the potential to impact industries such as: building construction, power generation and transmission, and microelectronics. This thesis focuses on the structure and properties of …

    maryland Repository record for Characterization of Copper Covetic Bulk and Films: Copper with High Carbon Content (opens in a new tab)

  10. A finite element calculation method for the heat transfer effects on the current-carrying capacity of underground electrical cables

    … cables. The demanding resources of cable ampacity finite element conduction code are further alleviated through a new technique dubbed EFECAC (Economic Finite Element for Cable Ampacity Calculation). This technique takes advantage of the fact that the heat dissipation in cables is nearly …

    concordia Download PDF for A finite element calculation method for the heat transfer effects on the current-carrying capacity of underground electrical cables (opens in a new tab)

  11. THERMAL ANALYSIS OF POWER LINES: METHODOLOGIES AND APPLICATIONS

    … reason it is necessary to calculate the cable ampacity that keeps the cable temperature under the insulation limit. The heat generated by the conductor ows radially from inside to outside (the surrounding medium can be air or earth, in case of buried cable) through all the cable layers. The …

    poli-torino Repository record for THERMAL ANALYSIS OF POWER LINES: METHODOLOGIES AND APPLICATIONS (opens in a new tab)

  12. On the Design of a High-Power Medium-Voltage Converter for Transportation Applications

    … systems, as well as the possibility of reducing ampacity requirements, is of intense interest. Medium-voltage dc systems provide significant improvements to power density compared to ac systems, and wide-bandgap devices enable operation at sufficiently high switching frequencies to make …

    alabama Repository record for On the Design of a High-Power Medium-Voltage Converter for Transportation Applications (opens in a new tab)

  13. Exploitation optimale des lignes électriques aériennes à haute tension par évaluation en temps réel de la flèche des conducteurs et du vent agissant sur la portée

    … wind speed has a dramatic impact on power line ampacity as it is the main variable responsible for cooling down the conductor, and hence for the sag value. However, a single-spot measurement does not allow knowing the global effect of the wind over the whole span, in particular for low wind …

    liege Repository record for Exploitation optimale des lignes électriques aériennes à haute tension par évaluation en temps réel de la flèche des conducteurs et du vent agissant sur la portée (opens in a new tab)