Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 83 for “"amperometric detection"”.

  1. Electrochemiluminescent & amperometric detection of DNA & DNA damage

    … of the redox polymers and DNA were used for dual amperometric and electrochemiluminescent detection of DNA damage, either by the formation of adducts by chemically generated damage or oxidative DNA damage, for use as a toxicity screening sensor. This system provides fast and accurate responses to …

    dcu Download PDF for Electrochemiluminescent & amperometric detection of DNA & DNA damage (opens in a new tab)

  2. Pulsed Amperometric Detection: a method for detecting amines in liquid chromatography

    … anodic waves at Pt electrodes. Furthermore, amperometric detection of these compounds at a constant potential fails due to the accumulation of adsorbed reaction products and/or an oxide film at the electrode surface. Pulsed Amperometric Detection (PAD) restores surface activity through the …

    iastate Repository record for Pulsed Amperometric Detection: a method for detecting amines in liquid chromatography (opens in a new tab)

  3. Determination of formaldehyde by ion exclusion and ion exchange separation with amperometric detection

    … and ion exchange separation followed by amperometric detection. Optimum eluant compositions and separation columns for the best separation have been determined, as well as the optimum working electrode, electrolytes, and applied potentials for the best detection. An internal …

    unlv Repository record for Determination of formaldehyde by ion exclusion and ion exchange separation with amperometric detection (opens in a new tab) Download PDF for Determination of formaldehyde by ion exclusion and ion exchange separation with amperometric detection (opens in a new tab)

  4. Pulsed Amperometric Detection of sulfur compounds at noble metal electrodes in aqueous solutions

    <p>The application of Pulsed Amperometric Detection (PAD) to inorganic and organic sulfur compounds is shown to be feasible at noble metal electrodes in aqueous solutions in conjunction with Flow-Injection (FI) and High Performance Liquid Chromatography (HPLC) analyses. Results are illustrated for …

    iastate Repository record for Pulsed Amperometric Detection of sulfur compounds at noble metal electrodes in aqueous solutions (opens in a new tab)

  5. Quantitation of maltooligosaccharides and determination of glucoamylase activity using pulsed amperometric detection for glucose

    <p>Several aspects of the application of pulsed amperometric detection (PAD) to carbohydrate analysis are addressed. The mechanism of glucose oxidation at a gold electrode was determined by cyclic voltammetry at a rotating disc electrode in the first study. Glucose oxidation was concluded to be …

    iastate Repository record for Quantitation of maltooligosaccharides and determination of glucoamylase activity using pulsed amperometric detection for glucose (opens in a new tab)

  6. Capillary electrophoresis with boron doped diamond electrode for amperometric detection of low molecular weight biological substrate

    … with a boron doped diamond electrode for amperometric detection. Chapter 1 introduced the capillary electrophoresis and electrochemical detection. It included the different modes of capillary electrophoresis, polyelectrolyte multilayers coating for open tubular capillary …

    cork Repository record for Capillary electrophoresis with boron doped diamond electrode for amperometric detection of low molecular weight biological substrate (opens in a new tab)

  7. Formation and characterization of prussian blue, polypyrrole and glucose oxidase modified electrodes for amperometric detection of glucose /

    To form and investigate amperometric glucose biosensor by modifying graphite and titanium electrodes with composite layer of prussian blue, polypirrole and glucose oxidase (PB-Ppy-GOx).

    vilnius Repository record for Formation and characterization of prussian blue, polypyrrole and glucose oxidase modified electrodes for amperometric detection of glucose / (opens in a new tab)

  8. Application of pulsed amperometric detection to reversed phase high performance liquid chromatography of some sulfur-containing pesticides

    … detector was demonstrated for the detection of sulfur-containing pesticides. The results presented for dimethoate are representative of all compounds studied;Cyclic voltammetry were concluded to be consistent with conclusions that oxidation of sulfur-containing pesticides involves …

    iastate Repository record for Application of pulsed amperometric detection to reversed phase high performance liquid chromatography of some sulfur-containing pesticides (opens in a new tab)

  9. Amperometric detection and electrochemical oxidation of aliphatic amines and ammonia on silver-lead oxide thin-film electrodes

    … materials for obtaining stable and sensitive amperometric and voltammetric signal when applied at constant or triangle waveform potentials for oxidation of aliphatic amines. Voltammetric and amperometric results were compared for detection of selected organic amines in carbonate buffer (pH 10) …

    iastate Repository record for Amperometric detection and electrochemical oxidation of aliphatic amines and ammonia on silver-lead oxide thin-film electrodes (opens in a new tab)

  10. Rapidly Scanning Coulostatic Liquid Chromatography/electrochemistry Combined With Conventional Amperometric Detection in a Series Dual-Electrode Cell

    The technique of rapidly scanning coulostatic pulse amperometry is combined with conventional fixed-potential amperometry in a series dual-electrode cell to create a novel detector for high performance liquid chromatography. After a preliminary period of electrode evaluation, a flow cell was …

    uiuc Repository record for Rapidly Scanning Coulostatic Liquid Chromatography/electrochemistry Combined With Conventional Amperometric Detection in a Series Dual-Electrode Cell (opens in a new tab)

  11. The development of pulsed waveforms for the electrochemical detection of inorganic and organic compounds in flow-injection analysis and liquid chromatography

    <p>Methods are described for the electrochemical detection of several classes of electroactive elements and compounds utilizing pulsed waveforms in flow-injection and liquid chromatographic systems. Particular emphasis is placed on the development of waveforms for the rejection of ubiquitous …

    iastate Repository record for The development of pulsed waveforms for the electrochemical detection of inorganic and organic compounds in flow-injection analysis and liquid chromatography (opens in a new tab)

  12. Chemical composition and fiber structure as factors affecting fiber fermentation

    … anion exchange chromatography and pulsed amperometric detection, resulted in superior separation and detection of the monosaccharides compared to current HPLC techniques employing refractive index. An anion exchange HPLC technique with pulsed amperometric detection for the analysis of …

    uiuc Repository record for Chemical composition and fiber structure as factors affecting fiber fermentation (opens in a new tab)

  13. Development of electrochemical detection for capillary electrophoreses

    … reliable and sensitive electrochemical (EC) detection for capillary electrophoresis. To achieve this goal, electrochemical behavior of the electrolyte and analytes and the factors affecting the behavior were studied by on-line cyclic voltammetry (CV) to understand electrode response. The …

    sask Repository record for Development of electrochemical detection for capillary electrophoreses (opens in a new tab)

  14. Studies on direct and indirect electrochemical immunoassays

    … reaction. Conditions were optimised for the amperometric detection of para-aminophenol, the electroactive product of the alkaline phosphatase catalysed hydrolysis of a new substrate, p-aminophenylphosphate, after separation by HPLC. The second approach involved the direct electrochemical …

    dcu Download PDF for Studies on direct and indirect electrochemical immunoassays (opens in a new tab)

  15. An Electrochemical Immunoassay System for Measuring Circulating Protein Biomarkers of Pediatric Soft Tissue Sarcoma

    … associated with disease can facilitate early detection, help guide treatment strategies and improve patient outcomes beyond current standards of care. The combination of inexpensive 3D-printed flow cells and electrochemical biosensors has recently emerged as a viable platform for low-cost, …

    etsu Repository record for An Electrochemical Immunoassay System for Measuring Circulating Protein Biomarkers of Pediatric Soft Tissue Sarcoma (opens in a new tab) Download PDF for An Electrochemical Immunoassay System for Measuring Circulating Protein Biomarkers of Pediatric Soft Tissue Sarcoma (opens in a new tab)

Page 1 of 5