Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 23 for “"apparent impedance"”.
-
Transient Stability Prediction based on Synchronized Phasor Measurements and Controlled Islanding
… PMUs data. It predicts transient stability using apparent impedance trajectories obtained from PMUs, decision trees, and FLDSD method. This method enables to find out the strategic locations for PMUs installation in the power system to rapidly predict transient stability. From the simulations …
-
Correlation of the transient energy margin to Out-of-step impedance relay operation
… energy function method, is related to the apparent impedance of a line protected by the out-of-step relay;In this procedure, only the multimachine system parameters are used, and the conventional intermediate step of forming a two-machine equivalent is eliminated;Two types of energy-based …
-
Next-generation, phasor-based distance relay with fault-path resistance immunity
… lines. A distance relay calculates the apparent impedance between the relay location and the fault location, and uses this value to determine the approximate location of the fault. Traditional distance relays, however, are plagued with problems caused by faults through a resistance. The …
-
An impedance based method for distribution system monitoring
… system will be shown. It will be shown that the apparent impedance measured on the feeder has great capabilities for on line monitoring of distribution feeder. The thesis establishes the steady-state mathematical model for defining the monitoring zone in R-X plane as the main contribution. It …
-
A novel backup protection scheme for hybrid AC/DC power systems
… protection. The protection scheme relies on the apparent impedance measured at the AC "side" of the MVDC link to detect faults on the DC system. It can be readily implemented on existing distance protection relays with no changes to existing measuring equipment. An overview of the literature in …
-
Stability control and protection of power systems with VSC HVDC and VSC FACTS
… The mathematical representation of the apparent impedance measurements of distance relay is derived considering the infeed current from VSC HVDC and VSC FACTS at different locations. A RTDS-based HIL testing platform is established. The impacts of VSC HVDC and VSC FACTS on feeder …
-
DESIGN AND SIMULATION OF SOFTWARE FOR A HIGH SPEED DIGITAL DISTANCE RELAY
… electric power systems. These relays estimate an apparent impedance of the protected line from the relay location to the fault and compare it with the relay settings for making decisions. Many approaches have been suggested in the past for developing distance relaying criteria that can be …
-
Estimação de Fasores para Proteção de Sistemas Elétricos Baseada em Mínimos Quadrados e Morfologia Matemática
… variations in method performance. Besides, the apparent impedance trajectory and estimated distance of the fault were analysed, and the presented method showed better results in comparison to one-cycle Fourier algorithm
-
Research into specific numerical protection maloperations
… relay maloperations on transmission lines using impedance protection algorithms. The research undertaken identifies the previously unidentified causes of the maloperations and describes a relay settings solution for improving the accuracy of the protective relays. The methodology that was …
-
A TECHNIQUE FOR ESTIMATING TRANSMISSION LINE FAULT LOCATIONS FROM DIGITAL IMPEDANCE RELAY MEASUREMENTS
… line shunt faults has been to measure the apparent impedance to the fault from a line terminal and convert the impedance to line length. One factor that adversely affects fault location estimates is the fault resistance that appears to the relay to be an impedance that has both resistive …
-
Wavelet transforms, neural networks and migration applied to magnetotellurics
… the electrical structures of the Earth. The impedance estimates are dependent on the natural sources and conventional Fourier transform techniques are not particularly suitable. The main focus in this dissertation is to automatically detect and process the magnetotelluric signals and enhance …
-
ESTIMATING THE LOCATION OF A TRANSMISSION LINE SHUNT FAULT FROM DIGITAL IMPEDANCE RELAY MEASUREMENTS
… a transmission line, conventionally measure the apparent impedance to the fault from a line terminal. This impedance is then converted to the line length. The fault location estimates are adversely affected by the presence of a fault resistance. The advent of microprocessor-based relays has made …
-
ESTIMATING LOCATIONS OF SHUNT FAULTS ON DISTRIBUTION LINES
… line shunt faults has been to measure the apparent impedance to the fault from a line terminal and convert the reactive component of the impedance to the line length. Several methods, that use the fundamental frequency voltages and currents measured at one or both line terminals, for …
-
Practical implementation of electrochemical impedance spectroscopy in battery characterization and management
Electrochemical impedance spectroscopy (EIS) offers rich, frequency-resolved information about the internal state of lithium-ion batteries, but its practical use onboard an operating battery system is limited by the relaxation effect, which requires the battery to rest for hours before a stable …
-
Determining the locations of faults in distribution systems
… transmission line faults has been to measure the apparent impedance from a line terminal to the fault and to convert the reactive component of the impedance to line length. Several methods, that use voltages and currents measured at one or both line terminals, have been proposed in the past. …
-
Fault Analysis and Control of DFIGs for Grid Code Compliance and Protection of Power System
… The focus is on the relays implemented using the apparent impedance approach and the commercially developed reactance method. It is revealed that the phase elements of a distance relay that uses these methods are prone to under-/over-reach in the systems with DFIGs. The exclusive fault behavior of …
-
Adaptive Settings Of Distance Relay For MOV-Protected Series Compensated Line With Distributed Capacitance Considering Wind Power
… protection operation. During faults, the impedance of the line is modified by an equivalent impedance of the parallel MOV/capacitor circuit, which affects the distance protection. The intermittent wind generation introduces additional complexity to the system performance and distance …
-
Voltage stability and distance protection zone3
… in zone2, since at that critical condition the apparent impedance seen by the distance relay traverse through all the three zones. Moreover, it is shown that switching out of major transmission lines is associated with large increase in power losses and if these losses are determined using …
-
A New Special Protection Scheme for Power System Controlled Separation
A new power system controlled separation scheme is proposed to prevent the propagation of cascading failures across a transmission network should it undergoes a major disturbance, thereby reducing the possibility of a large-scale blackout. This scheme is developed based on a set of conjectures, …
-
Novos desenvolvimentos na localização de faltas em sistemas de distribuição de energia elétrica fundamentada na impedância
Apesar do crescente desenvolvimento das metodologias de localização de faltas fundamentadas na impedância para sistemas de distribuição de energia elétrica nas últimas décadas, alguns aspectos ainda carecem de progressos, especialmente frente à crescente necessidade de aumento da qualidade da …
Page 1 of 2