Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 29 for “"apparent stiffness"”.

  1. Finite Element Analysis of Cortical Shell Contributions to Apparent Stiffness and the Effect of Vascular Apertures in Rat Vertebrae Under Uniaxial Compression

    … specific-finite element models to investigate stiffness sharing and axial strain distributions of cortical versus trabecular bone of rat L4 vertebral bodies with and without the inclusion of vascular apertures. In a previous experimental study, healthy (SHAM), osteoporotic (OVX) and treated …

    queens Repository record for Finite Element Analysis of Cortical Shell Contributions to Apparent Stiffness and the Effect of Vascular Apertures in Rat Vertebrae Under Uniaxial Compression (opens in a new tab)

  2. Validation of an in vivo model for monitoring trabecular bone quality changes using finite element analysis.

    … mechanical testing was used to determine the apparent stiffness and tissue modulus to quantify bone quality in rabbit distal femur trabecular bone. The objectives of this dissertation were two-fold. First, to develop the capabilities of micro CT scanning and micro CT image segmentation based …

    louisville Repository record for Validation of an in vivo model for monitoring trabecular bone quality changes using finite element analysis. (opens in a new tab)

  3. Validating Internal Density Calibration in The Proximal Humerus to Estimate Bone Stiffness Using Finite Element Analysis for Stemless Shoulder Arthroplasty

    … yet to be linked to finite element model (FEM) apparent stiffness in the context of stemless shoulder arthroplasty. Establishing stiffness as a measure of bone mechanical properties is a first step in accurately predicting bone strength in clinical CT images. The purpose of this thesis was to 1) …

    waterloo Repository record for Validating Internal Density Calibration in The Proximal Humerus to Estimate Bone Stiffness Using Finite Element Analysis for Stemless Shoulder Arthroplasty (opens in a new tab)

  4. Flexural behaviour of post-tensioned timber beams

    … results revealed that the strength and the stiffness for Group CD were increased on average by 70% and 10%, respectively, while the strength for Group C was increased on average by 56%. In contrast, the strength and the stiffness for Group SD were increased on average by 45% and 4%, …

    manitoba Repository record for Flexural behaviour of post-tensioned timber beams (opens in a new tab)

  5. INTERACTIONS BETWEEN BONE REMODELING AND MICRODAMAGE IN CANCELLOUS BONE

    … plate-like trabeculae leading to an increase in apparent stiffness, as predicted using finite element models. Although microarchitecture was modified, the improvements in apparent stiffness were well explained by changes in bone mass suggesting that treatment changes bone mass and not bone …

    cornell Repository record for INTERACTIONS BETWEEN BONE REMODELING AND MICRODAMAGE IN CANCELLOUS BONE (opens in a new tab)

  6. Cooperative impedance control with time-varying stiffness

    … motion and force and control a grasped object's apparent stiffness, damping, and inertia. Conventional impedance control practices have focused on position-based manipulators - which are inherently non-compliant - using constant, task-dependent impedances. In the event of large trajectory …

    unm Repository record for Cooperative impedance control with time-varying stiffness (opens in a new tab)

  7. Investigation of frictional resistance on orthodontic brackets when subjected to variable moments

    … kinetic and dynamic) and load (dynamic and apparent stiffness) were measured. Dynamic friction was the frictional force that occurred when the applied force was variable (dynamic load). The results showed that static and kinetic friction were similar while dynamic friction was statistically …

    wvu Repository record for Investigation of frictional resistance on orthodontic brackets when subjected to variable moments (opens in a new tab)

  8. Design analysis of single-span advanced composite deck-and-stringer bridge systems

    … presented. The design analysis covers: (1) ply stiffnesses and strengths; (2) laminate engineering stiffnesses; (3) apparent stiffness properties for composite decks; and (4) stringer stiffness properties. Finite element modeling is used to verify the accuracy of the design analysis.;For design …

    wvu Repository record for Design analysis of single-span advanced composite deck-and-stringer bridge systems (opens in a new tab)

  9. Numerical algorithms for the solution of a single phase one-dimensional Stefan problem

    … accurate approximations. It is observed that the apparent stiffness of the system of ordinary differential equations renders this second algorithm relatively inefficient.

    ubc Repository record for Numerical algorithms for the solution of a single phase one-dimensional Stefan problem (opens in a new tab) Download PDF for Numerical algorithms for the solution of a single phase one-dimensional Stefan problem (opens in a new tab)

  10. Nano-scale large area gap control for high throughput electrically induced micro-patterning

    … orientation and position control and high apparent stiffness to prevent the electric field from pulling the template and wafer together. In this research, high stiffness mechanism designs were investigated first. Such designs proved impractical, with travel, stiffness, and maximum side load …

    texas Repository record for Nano-scale large area gap control for high throughput electrically induced micro-patterning (opens in a new tab)

  11. Mechanics, additive manufacture, and characterisation of novel lattice biostructures

    … are reported. Analytical expressions for the apparent stiffness are derived accounting for filament flexure, diametrical compression, and response of tube under diametrically pinched load. Excellent agreement with numerical and experimental results is obtained.

    soton Download PDF for Mechanics, additive manufacture, and characterisation of novel lattice biostructures (opens in a new tab)

  12. Design and Testing of an Agonist-Antagonist Position-Impedance Controlled Myoelectric Prosthesis

    … of a control scheme able to identify object stiffness and regulate impedance. The system includes an algorithm to detect the apparent stiffness of an object, a proportional nonlinear EMG control algorithm for interpreting a user’s desired grasp aperture, and an antagonistically acting …

    vcu Repository record for Design and Testing of an Agonist-Antagonist Position-Impedance Controlled Myoelectric Prosthesis (opens in a new tab)

  13. Simple shear compaction of basecourse aggregates

    … cyclic simple shear tests have revealed an apparent stiffness recovery for granular specimens between test runs. This behaviour is difficult to explain, however it is thought to be related to the transition from a dynamic to a static state of friction within the specimen. The volume change …

    auckland-ms Repository record for Simple shear compaction of basecourse aggregates (opens in a new tab)

  14. Microstructure and Rheology of Process Cheese

    … poor meltability, toughness, breaking force, apparent stiffness modulus, degree of elasticity, apparent ultimate stress and inversely related to hysteresis and apparent ultimate strain. Tetrasodium pyrophosphate produced the most rapid emulsification of the fat in the cheese and sodium …

    utahstate Repository record for Microstructure and Rheology of Process Cheese (opens in a new tab)

  15. Multiscale characterisation of subchondral trabecular bone changes in the osteoarthritic ankle

    … which aided in assessing changes to the apparent-level stiffness of osteoarthritic bone. High-resolution medical imaging provided a means of detailed, three-dimensional morphological evaluation of the trabecular architecture, thus providing an insight to the remodelling of the bone with …

    whiterose Download PDF for Multiscale characterisation of subchondral trabecular bone changes in the osteoarthritic ankle (opens in a new tab)

  16. Realistic Wind Loads on Unreinforced Masonry Walls

    … the dynamically loaded walls exhibited higher apparent stiffness properties as compared to the quasi-statically loaded walls. The difference in the apparent stiffness between the dynamic and quasi-static specimens decreased with increasing damage levels until the dynamic stiffness converged to …

    sask Repository record for Realistic Wind Loads on Unreinforced Masonry Walls (opens in a new tab)

  17. The Effects of Coated Gold Nanorods on Porcine Atrioventricular Valve Tissues Using Atomic Force Microscopy

    … we examine the localized changes in apparent elastic modulus and stress relaxation behavior for the porcine mitral valve leaflets treated with the AuNRs with the atomic force microscope (AFM). We study these effects specifically because there is little literature available that …

    clemson Repository record for The Effects of Coated Gold Nanorods on Porcine Atrioventricular Valve Tissues Using Atomic Force Microscopy (opens in a new tab)

  18. Arch-rivals? The roles of the windlass and arch-spring mechanisms in running

    … mechanism’s function is to passively reduce arch apparent stiffness by changing its shape. The windlass mechanism’s ability to manipulate arch shape during running could be influenced by a straining plantar fascia however, as the plantar fascia is an important contributor to the arch-spring. …

    queens Repository record for Arch-rivals? The roles of the windlass and arch-spring mechanisms in running (opens in a new tab)

  19. Uncoupled Stability of Haptic Simulation of Viscoelastic Virtual Environments

    … from using KV VE, the HC model offers lower stiffness but higher damping range. To confirm the mapping, we conduct a user study to compare the viscosity and elasticity effects perceived by the users. Results show that different penetrations may not affect the stable HC elastic and viscous …

    queens Repository record for Uncoupled Stability of Haptic Simulation of Viscoelastic Virtual Environments (opens in a new tab)

  20. The Role of Architecture and Tissue Properties in the Structural Integrity of Human Vertebral Cancellous Bone

    … mass correlated similarly with cancellous bone stiffness and strength in females but not males. DXA could not account for variations in architecture detected by microCT, particularly in the thoracic spine, for either males or females. MicroCT scans may better assess bone strength in the thoracic …

    cornell Repository record for The Role of Architecture and Tissue Properties in the Structural Integrity of Human Vertebral Cancellous Bone (opens in a new tab)

Page 1 of 2