Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 204 for “"aqueous samples"”
-
Applications of functional materials in the analysis of aqueous samples
In chapter 1, a solid phase extraction method which allowed for enhanced qPCR output when detecting COVID-19 mRNA from complex wastewater streams across different wastewater treatment sites in Northern Ireland was developed.<br/>This work took two parallel research streams, in the first, a range of …
-
Molecularly imprinted polymers as selective sorbents for recognition in complex aqueous samples
Dans cette thèse, nous avons démontré la faisabilité de la préparation de polymères à empreinte moléculaires (MIP) hautement sélectifs pour la reconnaissance dans des matrices aqueuses complexes avec des applications dans les cosmétiques et en technologie alimentaire. Les MIP (de l'anglais …
-
The development of analytical instrument based on isotachophoresis (ITP) for measuring cations in aqueous samples
… emission spectrometry (ICP-OES). The number of samples analysed was: 8 samples of commonly available bottled water and 13 tap water samples from around the Europe, including samples from: Poland. Greece, France, Turkey and many locations in the UK. In the project nine different ITP electrolyte …
-
Development of multi-residue and selective methods for the ultra-sensitive determination of endocrine disrupting chemicals in aqueous samples
… methods for the determination of EDCs in aqueous samples. In the first part of the work, a multi-residue method is developed using sorptive extraction in combination with in-situ derivatization. Since the extraction of polar analytes is limited when using sorptive extraction with …
-
Analytical method development for ultra-trace determination of human pharmaceuticals in aqueous samples. Assessing the performance of a sewage treatment plant
Research focus in environmental pollution has recently been extended from more classical environmental pollutants such as PCBs or pesticides to pharmaceuticals and steroid hormones, which are designed to be biologically active and enter the environment primarily through regular domestic use. …
-
Characterizing a rapid extraction apparatus for the removal of VOCs from aqueous samples and interfacing it with fast analysis systems such as the aromatic specific laser ionization detector.
… in our laboratory for the removal of VOCs from aqueous samples in less than one minute. Also, a detector that is highly selective for aromatic VOCs will be discussed in detail. Extraction of VOCs from aqueous samples into the gas phase is often the timelimiting step in an analysis. A rapid …
-
Electrochemical investigations of interactions of trace metals : Pb(Ⅱ), Cd(ll), Cu(ll) and Mn(ll) with target trace metal Zn(ll) in binding by dissolved organic carbon in aqueous samples
… organic carbon (DOC) in freshwaters and mine aqueous effluents by determining metal speciation parameters: free metal ion concentration, stability constant, association/dissociation rate coefficient and diffusion coefficient. It was found that the interaction between trace metals and DOC is …
-
Novel materials and methods for solid-phase extraction and high-performance liquid chromatography
… and preconcentration of organic compounds from aqueous samples. Modified porous polystyrene-divinylbenzene (PS-DVB) resins containing polar groups are superior for SPE of organic solutes from aqueous samples. These modified resins display excellent surface hydrophilicity and improved extraction …
-
Simplex optimization of aluminum analysis by electrothermal atomic absorption spectrometry
… and magnesium nitrate, for aluminum analysis in aqueous samples using electrothermal atomic absorption spectrometry. Independent optimizations of sensitivity were performed over several practical concentration ranges for each matrix modifier and optimum concentrations were chosen by comparison of …
-
Ο ρόλος των μεταλλοπρωτεασών στην ανάπτυξη του αποφολιδωτικού γλαυκώματος: επίδραση της λατανοπρόστης
… the effect of latanoprost monotherapy on the aqueous humοr concentrations of TGF-beta1, MMP-2, TIMP-2, MMP-9 and gelatinolytic activity in patients treated for exfoliative glaucoma (XFG). Aqueous samples from 50 XFG patients treated with latanoprost and 50 age-matched XFG patients treated with …
-
Determination of Atrazine and Selected Respective Metabolites Using Strong Cation Exchange Resins
… desethylatrazine, and didealkylatrazine from aqueous samples is presented. Octadecyl bonded silica (C18) is widely used in analytical preconcentration schemes. While C18 presents a facile method of analyte removal, a new approach is needed to achieve greater trapping for polar analytes. In …
-
Nuevas estrategias de tratamiento de muestra para la determinación de contaminantes orgánicos en matrices medioambientales
… methodologies proposed in this paper. As for the samples studied, we have considered various environmental matrices: water and soil. Regarding the specific analytes, their selection was carried out based on their demonstrated toxicity to the environment (chlorophenols, chlorobenzenes and …
-
Spectroscopic analysis of samples in aqueous environments using a hollow core fiber
… obtained for graded concentrations of aqueous samples passing through the core of a stand alone hollow core fiber(HCF). Also, spectroscopic analysis of these samples is performed in a HCF coupler fabricated using silica core(SCF) single mode fiber. The SCF-HCF coupler is fabricated …
-
Development of a rapid, solvent extraction based radioanalytical technique for monitoring low-level actinide concentrations in water supplies
… analysis of radionuclides from large volume aqueous samples has been developed by using solvent extraction (SX) followed by quantification via liquid scintillation counting (LSC). This was accomplished using simple radiochemical techniques that resulted in the ability to enact a 200x …
-
Solid Phase Microextraction in Aqueous Sample Analysis
… analytical methods developed for complex aqueous sample analysis based on solid phase microextraction (SPME). First, the laboratory evaluation of the kinetic calibration approach in aqueous sample analysis using SPME is discussed. A modified SPME device, Polydimethylsiloxane (PDMS) rod …
-
Hydride Generation and Laser Spectroscopy Techniques for Trace Analytical Measurements of Antimony and Selenium
… (LIBS) detection techniques. In the LIF studies, aqueous samples of Sb are subjected to HG and the Sb hydride is carried to the flame which acts as an atomization source. The wavelengths of absorption and fluorescence emission for Sb were found to be 212.7 nm and 259.8 nm, respectively. The …
Page 1 of 11