Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"arterial model"”.

  1. Lab-On-A-Brane: A Novel Physiologically Relevant Planar Arterial Model to Study Transendothelial Transport

    … substantially mitigated by substituting animal models with in vitro devices that accurately model human cardiovascular transport. Here we present a novel physiologically relevant lab-on-a-brane that simulates in vivo pressure, flow, strain, and shear waveforms associated with normal and …

    uab Repository record for Lab-On-A-Brane: A Novel Physiologically Relevant Planar Arterial Model to Study Transendothelial Transport (opens in a new tab)

  2. Sensitivity analysis and parameter identification for a model of left ventricular mechanics and the systemic arterial load

    … associated with a third-order lumped-parameter model of the systemic arterial system has been developed previously (1). In the present study, a parameter sensitivity analysis of this model is conducted in conjunction with the identification scheme. This analysis indicates that the state …

    rice Repository record for Sensitivity analysis and parameter identification for a model of left ventricular mechanics and the systemic arterial load (opens in a new tab)

  3. Microfabrication Approaches for Understanding the Role of Vascular Mechanics in Progressive Diseases

    … microscopy technique and developed a thin-walled arterial model for growth and remodeling response to mechanical perturbations. We found that amyloid beta induces a reduction in vascular smooth muscle cell mechanical output. We implemented this loss of function into a constrained mixture arterial …

    umn Repository record for Microfabrication Approaches for Understanding the Role of Vascular Mechanics in Progressive Diseases (opens in a new tab)

  4. On the Transition of Non-Newtonian Blood Analogs in Straight and Stenosed Pipe Flow

    … to a commonly used Newtonian analog in in vitro models of healthy and stenotic arteries. Pressure drop of unobstructed steady, unsteady, and post-stenotic flows were measured across laminar, transitional and turbulent regimes of Newtonian pipe flow. Results have shown that the non-Newtonian blood …

    calgary Repository record for On the Transition of Non-Newtonian Blood Analogs in Straight and Stenosed Pipe Flow (opens in a new tab)

  5. Pulse propagation in the pulmonary and systemic arteries

    The one-dimensional model of Olufsen (2000) [*] for blood flow in the systemic arteries has been extended and built upon in a number of ways. Firstly, it has been applied to hypotheses of diseases of the systemic circulation, and that of the microcirculation. With a view to better understanding the …

    glasgow Download PDF for Pulse propagation in the pulmonary and systemic arteries (opens in a new tab)

  6. Three-Dimensional Collagen Tubes for In Vitro Modeling

    … a novel material for three-dimensional in vitro models. While two-dimensional models are typically inadequate for recreating the complex processes of the body, collagen provides a three-dimensional basis with a variety of applications, including remodeling of vascular cells under tension and …

    south-carolina Repository record for Three-Dimensional Collagen Tubes for In Vitro Modeling (opens in a new tab)

  7. The Effect of Calcified Plaque on Stress Within a Fibrous Thin Cap Atheroma in an Atherosclerotic Coronary Artery Using Finite Element Analysis (FEA)

    … was estimated using an idealized finite element arterial model. Also the thickness of the fibrous cap was varied to determine whether the stress was solely a function of lipid percentage or a combination. Plaque, arterial wall, lipid, and calcium were modeled using linear elastic, isotropic, and …

    calpoly Repository record for The Effect of Calcified Plaque on Stress Within a Fibrous Thin Cap Atheroma in an Atherosclerotic Coronary Artery Using Finite Element Analysis (FEA) (opens in a new tab)

  8. Patient-specific mechanics modelling of the left ventricle incorporating Hill’s mechanism with application to hypertension

    … to pathological left ventricular (LV) remodelling. This remodelling alters myocardial mechanics, governed by length- and velocity-dependent regulation via the Frank–Starling law and Hill’s force–velocity relation. Specifically, Hill’s force–velocity relationship characterises the …

    unsw Repository record for Patient-specific mechanics modelling of the left ventricle incorporating Hill’s mechanism with application to hypertension (opens in a new tab) Embargoed

  9. Evaluation of Stent Retriever Performance and Feasibility of an Auxetic Stent Retriever Design

    … were performed in a flow loop with models of increasing complexity to measure the SR removal force (i.e. force to dislodge the device from the occlusion site) and understand the influence of occlusion location on retrieval force. A 2D arterial model mimicking the tortuosity of an …

    utk-theses Repository record for Evaluation of Stent Retriever Performance and Feasibility of an Auxetic Stent Retriever Design (opens in a new tab)

  10. Simulating Blood Flow in an Anatomical Arterial Network

    … aim of this thesis is to develop a computational model of the human arterial system to predict blood pressure and ow rates throughout the body. The model used an anatomical vascular network derived from the Visible Human Project and implemented in OpenCMISS, an open-source mathematical modelling …

    auckland-ms Repository record for Simulating Blood Flow in an Anatomical Arterial Network (opens in a new tab)

  11. Distal Placement of an End-To-Side Bypass Graft Anastomosis A 3-D Computational Study

    … and turbulence, can be found distal to an arterial stenosis. Frequently, a bypass graft using an end-to-side technique is attached to a stenotic artery to restore adequate blood flow. However, a significant percentage of these grafts fail after thirty postoperative days due to intimal …

    odu Repository record for Distal Placement of an End-To-Side Bypass Graft Anastomosis A 3-D Computational Study (opens in a new tab)

  12. Stent design and arterial mechanics: parameterization tools using the finite element method

    … the abnormally high stresses imparted to the arterial wall as a result of stenting are an important factor in the treatment and development of cardiovascular diseases. Furthermore, normal physiologic diameter flcutuations between systole and diastole produce beneficial biological responses in …

    tamu Repository record for Stent design and arterial mechanics: parameterization tools using the finite element method (opens in a new tab)

  13. Coronary flow mechanics: an anatomically based mathematical model of coronary blood flow coupled to cardiac contraction

    … using an anatomically accurate computational model. Using Strahler ordered morphological data and an avoidance algorithm a three dimensional finite element model has been constructed of the largest six generations of the coronary arterial network within an anatomically accurate finite element …

    auckland-ms Repository record for Coronary flow mechanics: an anatomically based mathematical model of coronary blood flow coupled to cardiac contraction (opens in a new tab)

  14. The development of an integrated modelling framework to aid with the design of endovascular devices

    … and limitations of newly developed constitutive models as implemented into leading numerical analysis software suites. Specific attention is given to the Holzapfel soft tissue and Auricchio Nitinol constitutive models. Limitations and merits are explored through the development of an integrated …

    strathclyde Repository record for The development of an integrated modelling framework to aid with the design of endovascular devices (opens in a new tab)

  15. LOOKING TO THE FUTURE OF STROKE TREATMENT: COMBINING RECANALIZATION AND NEUROPROTECTION IN ACUTE ISCHEMIC STROKE

    … clinical stroke therapeutic needs. Few animal models of stroke target the large vessels that produce cortical deficits seen in the clinical setting. Also, current routes of drug administration, intraperitoneal and intravenous, do not mimic the clinical route of intra-arterial drug …

    uky-thes Repository record for LOOKING TO THE FUTURE OF STROKE TREATMENT: COMBINING RECANALIZATION AND NEUROPROTECTION IN ACUTE ISCHEMIC STROKE (opens in a new tab)

  16. Finite element analysis and material property modelling of thin-strut polymeric bioresorbable scaffolds

    … an improved consensus upon which material model(s) may be most appropriate for capturing the mechanical response of thin-strut BRS; and (iii) deploy a BRS into coronary artery geometry and design a novel BRS for use in a challenging clinical scenario. Firstly, finite element analysis was …

    soton Download PDF for Finite element analysis and material property modelling of thin-strut polymeric bioresorbable scaffolds (opens in a new tab)

  17. 3D Printed, Physiologically Compliant, Nonlinear, Simple Equine Pulmonary Artery Phantom: Fabrication Technique and Observations on Mechanical Properties and Pulsatile Behavior

    … physiology. The extraordinary pulmonary arterial pressure (200 mmHg) of exercising horses suggests that hemodynamic events are likely an important pathophysiologic component of this condition, however the basis of pulse wave energy transmission in large arteries remains controversial and …

    guelph Repository record for 3D Printed, Physiologically Compliant, Nonlinear, Simple Equine Pulmonary Artery Phantom: Fabrication Technique and Observations on Mechanical Properties and Pulsatile Behavior (opens in a new tab)