Evaluation of ceramics as a material for Total Disc Replacements
… by replacing the intervertebral disc with an articulating or flexible implant. One reason Total Disc Replacements fail is aseptic loosening of the implant, caused by osteolysis, an inflammatory response to the wear debris produced by the articulating surfaces of the implant. Therefore, it is …
-
Vertebral Aging Using Osteoarthritic Conditions
… consistent when examining individual inferior articulating surfaces on both the left and right sides of the cervical spine. No significant correlations were observed between osteoarthritis and sex, body mass index (BMI), or occupational activity for these joints or surfaces. The cervical GLM …
-
An experimental investigation of wear behavior of ultra-high molecular weight polyethylene under sliding motion
… motion on the materials that are used as bearing surfaces of human total-joint replacement prostheses. The tests are performed with a specially designed equipment based on pin-on-disk machine. The testing machine is designed and constructed to reproduce sliding motion, applied to spherical ended …
-
Nanoparticle sensors and lubricants for degenerative articular cartilage
… to reduce the coefficient of friction between articulating surfaces, with the pressurized fluid supporting 95% of applied loads. Experiencing millions of articulations throughout an average lifetime, articular cartilage possesses distinct biotribological properties. These require effective …
-
Calibration and optimization of a biplane fluoroscopy system for quantifying foot and ankle biomechanics
… kinematics and the biomechanical behavior of the articulating surfaces, the ligaments, and tendons acting as soft tissue constraints. Understanding the relationships between anatomic morphology and healthy joint function, and how conservative and surgical treatments affect symptomatic behavior in …
-
Design and evaluation of an encapsulated artificial disc
… devices include ball and socket articulation surfaces that can induce high frictional torques and wear rates. When these particles interact with the surrounding tissues they can induce inflammations leading to osteolysis, subsidence of the implant and then revision surgery. A new device has …
-
Surface modification of ASTM F-1537 Co-Cr alloy by low temperature plasma surface alloying
… of numerical nano- sized wear debris from the articulating surfaces. In this work, medical grade ASTM F-1537 Co-Cr alloy has been plasma nitrided (PN) and carbonitrided (PCN) at 300-400°C for 10-30 h. The microstructure and the mechanical, chemical and tribological properties of the modified …
-
Research into the Design and Validation of an Innovative Intraoperative Load Sensor for Total Knee Replacements through Experimental and Cadaveric Investigations
… for patients due to the complexity of the joint, articulating surfaces, tendons, and ligaments. These structures are all impacted by the forces created in the joint following a TKR. A lack in equilibrium can cause an asymmetric gait, pain, a decrease in range of motion (ROM), loosening of the …
-
Contact stress analysis of surface guided knee implant using finite element modeling
… High Molecular Weight Polyethylene (UHMWPE) articulating surface, decreasing the longevity of the implant. The contact stresses are influenced by the kinematics, the bearing congruency of the articulating surfaces and insert thickness. Thus, various studies have focused on the prediction and …
-
Wear of polyethylene and hylamer on cobalt-chromium : a knee simulator study
… ran at 2 Hz with saline being sprayed between articulating surfaces. Simulation I tested six UHMWPe bearings with an off-center load applied to the bearing by the femoral component 25 from the articulating surface segment tangent. Simulation II tested three Hylamer and three UHMWPe bearings …
-
Investigation of the performance of articular cartilage and synthetic biomaterials in multi-directional sliding motion as in orthopedic implants
… in terms of their suitability for use as articulating surfaces in artificial joints. The Dual-Axis Wear Simulator (DAWS), a wear testing machine that simulates conditions in a synovial joint, was designed and fabricated to enable investigators to measure the wear of such materials in …
-
Articular Morphology in Human Limb Synovial Joints: Variation, Covariation, and Application
… relationships within and among our joint surfaces. This dissertation is the first study to analyze intra- and inter-joint variation for all the major joints of the upper and lower limb in the modern human skeleton, and to explore potential applications of the patterns observed.</p> <p>To …
-
Multilayered Nanostructured Diamond Coatings for Temporomandibular Joint Prostheses
… nanostructured diamond (NSD) coatings on the articulating surfaces of Ti-6Al-4V are of interest. NSD coatings synthesized by microwave plasma chemical vapor deposition (MPCVD) feature many desirable properties, including low surface roughness, high hardness, wear resistance, and …
-
Mesenchymal Stem Cell Interaction With Nanostructured Biomaterials for Orthopaedic Applications
… may be the improvement of wear resistance at the articulating surfaces by substituting materials with greater hardness. This dissertation describes two strategies for increasing the surface hardness of titanium alloy (Ti-6Al-4V) implants, without increasing surface roughness or compromising …
-
Customized surface-guided total knee replacement for natural kinematics and deep flexion
… this design concept, specially shaped asymmetric articulating surfaces aim to guide the motion through a predefined target pattern of motion. The novel design features of the tibiofemoral articulation surfaces were generated based on patient-specific anatomic measurements of the reference …
-
Characterization of Potential Wear Sources in Knee Arthroplasty Prostheses After In Vivo Function
… wear debris originates from four main locations: articulating surfaces, modular component surfaces, surfaces of fixation, and adjuvant fixation devices. Each of these possible wear sources can initiate the cascade of failure associated with wear-induced osteolysis and lead to subsequent revision …
-
Function and failure mechanisms of dual mobility bearings for total hip replacement
… liner therefore introducing a secondary articulating surface between the liner and acetabular component. Despite their emerging use, the in-vivo function of these implants is not well understood. Early evidence suggests that DM THRs may perform poorer than conventional designs, and …
-
A Framework to Fuse Subject-Specific Musculoskeletal Models into Knee Finite Element Analyses
… the geometry of the knee, and in particular the articulating surfaces of the tibial, patellar, and femoral cartilage. The workflow developed in Chapter 3 reconstructs major lower limb bone segments (pelvis, femur, tibia, fibula, and patella), knee cartilage volumes and major ligamentous …
-
Specimen-Specific Natural, Pathological, and Implanted Knee Mechanics Using Finite Element Modeling
… include osteoarthritis (degradation of the articulating surfaces), patellofemoral pain, and cruciate ligament injury and/or rupture. The complex behavior of knee motion presents unique challenges in the diagnosis of knee pathology and restoration of healthy knee function. Quantifying knee …