Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 13 of 13 for “"artificial circulation"”.

  1. Blood pressure signal simulation in an artificial circulation system

    … a desired pressure waveform in an artifical circulation system by using a Z-80 microcomputer controlled stepper motor. This will simulate the desired blood pressure waveform in the human body and can be used for clinical application.</p><p>A microcomputer simulation was used for setting up an …

    njit Repository record for Blood pressure signal simulation in an artificial circulation system (opens in a new tab)

  2. An investigation of characteristics of blood velocity in a simulated circulation system

    … the vessel of a Z-80 microprocessor controlled artificial circulation system.</p><p>Three methods were used to detect the velocity in the vessel: continuous wave Doppler, Pulse Doppler, and a hot-film device. The first method can get the average velocity, while the latter two have the capability …

    njit Repository record for An investigation of characteristics of blood velocity in a simulated circulation system (opens in a new tab)

  3. Impact of an artifical circulation device on the heat budget of an ice-covered mid-latitude lake

    … investigation in order to assess the impact of artificial circulation on the heat budget of a small mid-latitude ice-covered lake. The heat transfer algorithm developed by Patterson & Hamblin (1988) for high latitude lakes was extended to include the impacts of snowmelt due to rain, sediment …

    ubc Repository record for Impact of an artifical circulation device on the heat budget of an ice-covered mid-latitude lake (opens in a new tab) Download PDF for Impact of an artifical circulation device on the heat budget of an ice-covered mid-latitude lake (opens in a new tab)

  4. A computer model for circular and linear bubble plumes

    The purposes of this research were to implement the circular plume model developed by Wuest et al. (1992) and to develop and verify a linear plume model based on the circular model. The linear model developed is the first that models a bubble plume generated by a linear source in thermally …

    vt Repository record for A computer model for circular and linear bubble plumes (opens in a new tab)

  5. Two-Phase Bubble Flow Modelling for Restoration of Eutrophic Lakes

    … eutrophic, anoxic lakes, this thesis considers artificial circulation as a technique by introducing air bubbles into the lake water, which has the advantage that no chemical substances will be added to the lake water. This study aims to improve the understanding of the hydrodynamic behaviour of …

    concordia Download PDF for Two-Phase Bubble Flow Modelling for Restoration of Eutrophic Lakes (opens in a new tab)

  6. Vidurinės sternotomijos ir ministernotomijos aortos vožtuvo keitimo operacijų rezultatų palyginimas /

    … aorta clamp duration and increased duration of artificial circulation compared with the median sternotomy group. The length of surgery for patients of both groups is only slightly different. Postoperative characteristics: During stay in an intensive care unit, patients of the ministernotomy …

    vilnius Repository record for Vidurinės sternotomijos ir ministernotomijos aortos vožtuvo keitimo operacijų rezultatų palyginimas / (opens in a new tab)

  7. Aortic valve replacement through median sternotomy and ministernotomy: a comparison of the results /

    … aorta clamp duration and increased duration of artificial circulation compared with the median sternotomy group. The length of surgery for patients of both groups is only slightly different. Postoperative characteristics: During stay in an intensive care unit, patients of the ministernotomy …

    vilnius Repository record for Aortic valve replacement through median sternotomy and ministernotomy: a comparison of the results / (opens in a new tab)

  8. Studies on blood platelets in uraemia

    … calcium plus adenosine diphosphate (ADP) in an artificial circulation system (the Chandler tube technique), and by a turbidimetric method. Platelet aggregation with ADP and its reversal was studied by a turbidimetric system. The ability of platelets to adhere to glass surfaces was measured by a …

    glasgow Download PDF for Studies on blood platelets in uraemia (opens in a new tab)

  9. Studies with plasminogen activators

    … which tissue activator may be released into the circulation, was studied. A similar pattern of fibrinolytic activity to that produced by streptokinase was found, with liability to a serious coagulation defect. Tissue activator does not therefore appear on the basis of these observations to have …

    glasgow Download PDF for Studies with plasminogen activators (opens in a new tab)

  10. Blood Platelets and Proteolytic Enzymes

    … aggregation was assessed in two ways; by an artificial circulation system - the Chandler tube system, which measures the rate of formation of platelet aggregates in flowing recalcified citrated plasma, and by a turbidimetric method which measures the ability of platelets in response to …

    glasgow Download PDF for Blood Platelets and Proteolytic Enzymes (opens in a new tab)

  11. Simulation of AIDS patient detoxification by an extracorporeal device and related experimental studies

    <p>A simple numerical simulation of an AIDS patient detoxification by an extracorporeal device for the removal of virus has been designed. The mathematical model accounts for healthy white cells (W) attacking and destroying the virus (V), while at the same time the virus attacks and infects certain …

    njit Repository record for Simulation of AIDS patient detoxification by an extracorporeal device and related experimental studies (opens in a new tab)