Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 36 for “"artificial kidney"”.

  1. Design of a capillary artificial kidney

    An engineering study was made of an artificial kidney— one of the major components used in the treatment of patients suffering from chronic uremia. As the capillary artificial kidney offered the most advantages over other systems, an analysis of the mass transfer and blood flow characteristics of …

    ubc Repository record for Design of a capillary artificial kidney (opens in a new tab) Download PDF for Design of a capillary artificial kidney (opens in a new tab)

  2. Physiological transport parameters in the patient-artificial kidney system

    … weight spectra for the patient-artificial kidney system.

    texas Repository record for Physiological transport parameters in the patient-artificial kidney system (opens in a new tab)

  3. A Study of the Portable and Fully Automated Artificial Kidney

    … and evaluation of a portable and fully automated artificial kidney platform. The first part of this work evaluates albumin dialysis as a strategy for removing representative protein-bound toxins. An in vitro albumin dialysis circuit was used to compare polysulfone and cellulose dialyzers over a …

    washington Repository record for A Study of the Portable and Fully Automated Artificial Kidney (opens in a new tab)

  4. Effects of an ion exchange resin artificial kidney in dogs

    Thesis (M.S.)--Michigan State University of Agriculture and Applied Science. Dept. of Surgery and Medicine, 1960

    msu Repository record for Effects of an ion exchange resin artificial kidney in dogs (opens in a new tab)

  5. Surface characterization of hollow fiber dialysis membranes used in artificial kidney.

    The internal and external surfaces of dialysis hollow fiber membranes were characterized by the combination of two techniques, e.g. contact angle measurement (CAM) and atomic force microscopy (AFM), aiming at the improvement of membrane biocompatibility. A number of surface properties including …

    ottawa-retro Repository record for Surface characterization of hollow fiber dialysis membranes used in artificial kidney. (opens in a new tab)

  6. A portable artificial kidney system using microfluidics and multi-step filtration

    Natural kidney filtration is a compact, multi-step filtration process which passes wastes and exceeded fluids via microscale vessels in glomerulus and tubules. The principal renal replacement therapy (RRT), commonly called dialysis, is a single-step filtration process based on diffusion to replace …

    unsw Repository record for A portable artificial kidney system using microfluidics and multi-step filtration (opens in a new tab)

  7. A mathematical model for simulation of solute transport within the patient-artificial kidney system

    … hemodialysis, a multicompartmental patient-artificial kidney model has been developed. In vivo clinical data in the form of solute-plasma concentration decline measurements following an impulse IV injection of Dextran-1500 (1500 molecular weight dextran fraction) and Vitamin B-12 have been …

    texas Repository record for A mathematical model for simulation of solute transport within the patient-artificial kidney system (opens in a new tab)

  8. Testing and analysis of microfluidics and reverse osmosis membranes in the development of a portable artificial kidney

    The prevalence of kidney failure continues to rise, while conventional hemodialysis remains constrained by bulky equipment, dialysate dependence, and frequent treatment schedules, all of which limit patient mobility and quality of life. The development of portable and implantable artificial kidneys …

    unsw Repository record for Testing and analysis of microfluidics and reverse osmosis membranes in the development of a portable artificial kidney (opens in a new tab) Embargoed

  9. Quality of life assessment of chronic hemodialysis patients at the Artificial Kidney Unit of Good Samaritan Hospital and Medical Center

    … hemodialysis patient population served by the Artificial Kidney Unit at Good Samaritan Hospital and Medical Center, Portland, Oregon. The intent of the study was to discover if there was a significant difference in quality of life between patients who dialyzed at home and patients at the …

    portland-state Repository record for Quality of life assessment of chronic hemodialysis patients at the Artificial Kidney Unit of Good Samaritan Hospital and Medical Center (opens in a new tab)

  10. ΣΥΓΚΡΙΣΗ ΤΩΝ ΜΕΤΑΒΟΛΩΝ ΑΣΒΕΣΤΙΟΥ ΚΑΙ ΜΑΓΝΗΣΙΟΥ ΣΤΟΝ ΟΡΟ ΤΟΥ ΑΙΜΑΤΟΣ ΚΑΙ ΣΤΟΝ ΣΚΕΛΕΤΙΚΟ ΜΥ ΚΑΤΑ ΤΗΝ ΔΙΑΡΚΕΙΑ ΤΡΟΠΟΠΟΙΗΜΕΝΗΣ ΑΙΜΟΔΙΑΛΥΣΙΣ

    … TO THE CONCENTRATION OF THE SOLUTION OF THE ARTIFICIAL KIDNEY IN CA2+ AND MG2+ IONS. THE ANIMALS WERE HAEMODIALYSED FOR 90 MINUTES WHILE BLOOD SAMPLES WERE TAKEN EVERY 30 MIN FOR ELECTROLYTES DETERMINATION. IN ADDITION FROM EVERY ANIMAL A SMALL PIECE OF SKELETAL MUSCLE WAS TAKEN IN THE …

    greece Repository record for ΣΥΓΚΡΙΣΗ ΤΩΝ ΜΕΤΑΒΟΛΩΝ ΑΣΒΕΣΤΙΟΥ ΚΑΙ ΜΑΓΝΗΣΙΟΥ ΣΤΟΝ ΟΡΟ ΤΟΥ ΑΙΜΑΤΟΣ ΚΑΙ ΣΤΟΝ ΣΚΕΛΕΤΙΚΟ ΜΥ ΚΑΤΑ ΤΗΝ ΔΙΑΡΚΕΙΑ ΤΡΟΠΟΠΟΙΗΜΕΝΗΣ ΑΙΜΟΔΙΑΛΥΣΙΣ (opens in a new tab)

  11. Iterative Design and Proof of Concept Prototypes – Emergency Safety Valve for Portable Hemodialysis System

    … central venous catheters and the CDI’s portable artificial kidney. When activated by a sudden tensile force, the emergency safety valve will undergo disconnection causing deployment of the crushing mechanism and thus, stop blood flow within the dialysis system. This thesis followed a product …

    washington Repository record for Iterative Design and Proof of Concept Prototypes – Emergency Safety Valve for Portable Hemodialysis System (opens in a new tab)

  12. Optimization of flow in the collecting duct during the concentrating mode and the diluting mode in a nephron population of two different length with the renin angiotensin system and ADH mechanism

    … and long nephrons are interacting in the human kidney to adjust the flow in the collecting duct to have the maximum flow during the diluting mode and minimum flow during the concentrating mode. The best lengths for the short nephron and long nephron are calculated during the concentrating mode …

    njit Repository record for Optimization of flow in the collecting duct during the concentrating mode and the diluting mode in a nephron population of two different length with the renin angiotensin system and ADH mechanism (opens in a new tab)

  13. The dialysis of caffeine through selected semi-permeable membranes

    … has been used as the dialysis membrane in the artificial kidney since the machine’s inception in 1914. It continues to serve in this capacity, even though, in the last few years, attempts have been made to develop better films.An appreciation of both the “solution theory” and the “pore theory” …

    u-pacific Repository record for The dialysis of caffeine through selected semi-permeable membranes (opens in a new tab)

  14. Diffusion studies with novel plastics

    … in particular, for possible use with the artificial kidney. Diffusion experiments were conducted with sodium chloride, urea and uric acid. Experimental results were compared to diffusion coefficients calculated in the literature for cellulose membranes. The results show that the rates of …

    njit Repository record for Diffusion studies with novel plastics (opens in a new tab)

  15. ΜΕΛΕΤΗ ΤΗΣ ΑΔΕΝΟΣΙΝΟ-ΑΠΑΜΙΝΑΣΗΣ ΤΩΝ ΛΕΜΦΟΚΥΤΤΑΡΩΝ ΕΠΙ ΧΡΟΝΙΑΣ ΝΕΦΡΙΚΗΣ ΑΝΕΠΑΡΚΕΙΑΣ

    … UNDER CONSERVATIVE THERAPY AND THOSE TREATED BY ARTIFICIAL KIDNEY IS NOT STATISTICALLY SIGNIFICANT. THE UREMIC TOXINS WHICH ARE PROBABLY RESPONSIBLE FOR THE IMPAIRMENT OF THE ACTIVITY OF THE ENZYME ARE NOT DIALYSABLE.

    greece Repository record for ΜΕΛΕΤΗ ΤΗΣ ΑΔΕΝΟΣΙΝΟ-ΑΠΑΜΙΝΑΣΗΣ ΤΩΝ ΛΕΜΦΟΚΥΤΤΑΡΩΝ ΕΠΙ ΧΡΟΝΙΑΣ ΝΕΦΡΙΚΗΣ ΑΝΕΠΑΡΚΕΙΑΣ (opens in a new tab)

  16. Η ΕΠΙΔΡΑΣΙΣ ΤΗΣ ΙΣΟΠΡΟΤΕΡΕΝΟΛΗΣ Η ΤΗΣ ΜΥΟΚΑΡΔΙΑΚΗΣ ΙΣΧΑΙΜΙΑΣ ΕΠΙ ΤΟΥ ΜΑΓΝΗΣΙΟΥ ΤΟΥ ΜΥΟΚΑΡΔΙΟΥ ΕΠΙ ΥΠΑΣΒΕΣΤΙΑΙΜΙΑΣ: πειραματική μελέτη

    … DOGS (6 GROUPS) AND CONNECTED THEM WITH ARTIFICIAL KIDNEY. HYPOCALCAEMIA WAS ACHIEVED IN GROUPS B, D, F. INTRAVENOUS ISOPROTERENOL WAS GIVEN IN GROUPS C, D AND CORANARY ARTERY LIGATION FOR 7 MIN WAS PERFORMED IN GROUPS E, F. MYOCARDIAL MAGNESIUM WAS MEASURED IN PART OF THE LEFT …

    greece Repository record for Η ΕΠΙΔΡΑΣΙΣ ΤΗΣ ΙΣΟΠΡΟΤΕΡΕΝΟΛΗΣ Η ΤΗΣ ΜΥΟΚΑΡΔΙΑΚΗΣ ΙΣΧΑΙΜΙΑΣ ΕΠΙ ΤΟΥ ΜΑΓΝΗΣΙΟΥ ΤΟΥ ΜΥΟΚΑΡΔΙΟΥ ΕΠΙ ΥΠΑΣΒΕΣΤΙΑΙΜΙΑΣ: πειραματική μελέτη (opens in a new tab)

  17. A systems approach to renal dialysis

    … mathematical model of the patient - artificial kidney machine system consisting of several interconnected subsystems of the human organism. The model is based on current general physiological knowledge, but can be tailored to simulate individual patients by adjusting model parameters. …

    city-london Download PDF for A systems approach to renal dialysis (opens in a new tab)

Page 1 of 2