Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 16 of 16 for “"artificial sweat."”.

  1. Development of a Redox Functional Nucleic Acid Integrated Electrochemical Biosensors for Wearable Applications

    … Initial trials utilizing cortisol mixed artificial sweat and DI samples demonstrated its performance in cortisol detection with an LOD of 59 nM in artificial sweat. The assay's reusability was tested through multiple incubations with a standard cortisol solution, indicating consistent …

    calgary Repository record for Development of a Redox Functional Nucleic Acid Integrated Electrochemical Biosensors for Wearable Applications (opens in a new tab)

  2. Hand eczema and contact allergy in healthcare work

    … available DPG was released from the glove into artificial sweat. Compared to a nitrile glove, proportionally more DPG was released into artificial sweat from the polyisoprene glove

    lund Repository record for Hand eczema and contact allergy in healthcare work (opens in a new tab) Download PDF for Hand eczema and contact allergy in healthcare work (opens in a new tab)

  3. Multiphase Interfacial Phenomena for Liquid Manipulation and Defrosting

    … salts). We leverage the composition of human sweat (97% water and 3% minerals) and employ a hygroscopic substance near the outlet of an artificial sweat duct rig. This leads to complete diffusion and dehydration of sweat, forming a natural mineral plug within the artificial sweat duct that …

    vt Repository record for Multiphase Interfacial Phenomena for Liquid Manipulation and Defrosting (opens in a new tab)

  4. On-body trials for wearable laser-induced graphene biosensors

    … become more robust via electrochemical sensors. Sweat sensors are also of interest due to the utilization of a non-invasive method to measure these chemicals and can give continuous feedback. For as much as these sensors have advanced, there is a lack of rigorous testing in on-body scenarios. The …

    iastate Repository record for On-body trials for wearable laser-induced graphene biosensors (opens in a new tab)

  5. Contact allergy to heavy metals: risk factors and pathogenesis /

    … - day and week - contact with wire and nails in artificial sweat. An experiment on the penetration of Cr through the skin using Franz cells and two different media (petrolatum and water) was carried out. Quantitative analysis of human INFγ, IL-1α, IL-1β, IL-9, IL-13, IL-17A, IL-22, and IL-23 in …

    vilnius Repository record for Contact allergy to heavy metals: risk factors and pathogenesis / (opens in a new tab)

  6. Solid state laser synthesis of high entropy nanomaterials as elecrocatalysts for water electrolysis and biosensing

    … stability, and selectivity, including in artificial sweat samples. Overall, the dissertation shows that direct CO₂ laser writing is a versatile and scalable method for creating high-entropy nanomaterials and demonstrates how these materials can be engineered to solve real-world problems in …

    missouri Repository record for Solid state laser synthesis of high entropy nanomaterials as elecrocatalysts for water electrolysis and biosensing (opens in a new tab) Embargoed until 2026-12-01

  7. Screen Printed Carbon Electrode Based Microfluidic Biosensor for Sweat Cortisol Detection

    … electrode (SPCE) was developed for detection of sweat cortisol with point of care applications. Cortisol detection in artificial sweat is an important screening tool for diagnosis and monitoring of various health conditions like Addison’s disease, stress disorder, and Cushing’s syndrome. A …

    sdstate Repository record for Screen Printed Carbon Electrode Based Microfluidic Biosensor for Sweat Cortisol Detection (opens in a new tab)

  8. Highly Reproducible Electrochemical Sensors towards Wearable Applications and Pharmaceutical Analysis

    … and potassium ions in aqueous solution and artificial sweat were fabricated. This technology was also applied for the development of a highly reproducible paper-based ion-selective electrode for the determination of fluoxetine.

    ucf Repository record for Highly Reproducible Electrochemical Sensors towards Wearable Applications and Pharmaceutical Analysis (opens in a new tab)

  9. Microstructure Configuration of Zn-AgCl Electrodes towards High Performance Aqueous Batteries

    … battery. These electrolytes included seawater, artificial sweat, and zinc chloride solution. Under a current density of 1 mA/cm², the seawater-based Zn-AgCl battery can achieve a specific capacity up to 3 mAh/cm². Moreover, the sweat-activated zinc-silver chloride battery demonstrated better …

    unsw Repository record for Microstructure Configuration of Zn-AgCl Electrodes towards High Performance Aqueous Batteries (opens in a new tab) Embargoed

  10. Low-Cost Wearable Biosensors for Virus and Lithium Monitoring in Healthcare

    … at very low concentrations for monitoring in sweat. Lithium is used to treat bipolar disorder and has a narrow range (0.4 - 1.2 mM) for effectiveness and non-toxicity. This low-cost and wearable sensor, made from conductive polymer and ionophore as the working electrode and with graphene as a …

    tamu Repository record for Low-Cost Wearable Biosensors for Virus and Lithium Monitoring in Healthcare (opens in a new tab)

  11. Evaluation of antimicrobial coatings in wet conditions and development of sulphonated poly (ether ether ketone) - copper composites for antimicrobial applications

    … expected to oxidize when exposed to human palm sweat or disinfection agents in healthcare settings. To investigate this possibility, the antimicrobial efficacy and durability of this coating was evaluated under exposure to different saline environments (artificial ocean water and artificial …

    waterloo Repository record for Evaluation of antimicrobial coatings in wet conditions and development of sulphonated poly (ether ether ketone) - copper composites for antimicrobial applications (opens in a new tab)

  12. A NOVEL CHARACTERIZATION OF ORGANIC POLYMER INTERFACES USING REMOTE-GATE FIELD-EFFECT TRANSISTORS

    … of cortisol detection in a lightly buffered artificial sweat that showed LOD of 1 ng/ml. Finally, a sandwich enzyme-linked immunosorbent assay is performed to confirm antibody binding activity of antibody-embedded PSMA.

    jhu Repository record for A NOVEL CHARACTERIZATION OF ORGANIC POLYMER INTERFACES USING REMOTE-GATE FIELD-EFFECT TRANSISTORS (opens in a new tab)

  13. Development of Nanozyme and Nanozyme-Enhanced Electrode for Electrochemical Lactate Sensing

    … for electrochemical detection of lactate in sweat. GLAD NiO electrodes exhibit high sensitivity (412 μA mM-1 cm-2), wide linear detection range (1–45 mM), low detection limit (3 μM), and excellent specificity in artificial sweat samples. The unique microporous structure of the GLAD NiO …

    waterloo Repository record for Development of Nanozyme and Nanozyme-Enhanced Electrode for Electrochemical Lactate Sensing (opens in a new tab)

  14. Antimicrobial functionalization of technical textiles for medical, aerospace and civil applications

    … Silver ion release test in water and in artificial sweat showed a progressive and gradual release of silver ions, beneficial for prolonged antimicrobial activity. The nature of the fabric substrate was also found to influence the release of silver ions. The coating showed effective …

    poli-torino Repository record for Antimicrobial functionalization of technical textiles for medical, aerospace and civil applications (opens in a new tab)

  15. Low-Dimensional Nanostructured Catalysts of Copper Oxides and Nickel Oxides Supported on Graphene and Their Applications in Biosensing and Photoelectrochemical Hydrogen Evolution

    … sample is also tested for lactate sensing in an artificial sweat electrolyte, and it exhibits a reduced linear range of 0.02-53.1 mM and a lower limit of detection of 0.00013 mM, but the same high sensitivity of 80.0 μA mM-1 cm-2. This sensing performance can be optimized by controlling the NiOOH …

    waterloo Repository record for Low-Dimensional Nanostructured Catalysts of Copper Oxides and Nickel Oxides Supported on Graphene and Their Applications in Biosensing and Photoelectrochemical Hydrogen Evolution (opens in a new tab)

  16. Tenké vrstvy plazmového polymeru na kovových substrátech

    Tato práce je v teoretické části zaměřena na povrchové úpravy, jejich hodnocení z hlediska vzhledových vlastností, plazmochemickou depozici z plynné fáze a na analýzu tenkých vrstev připravených plazmovou polymerací. V experimentální části se práce zaobírá povrchovou úpravou korozivzdorné oceli …

    brno-tech Repository record for Tenké vrstvy plazmového polymeru na kovových substrátech (opens in a new tab)