Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 5 of 5 for “"artificial tear fluid"”.

  1. Phospholipid Transport in Silicon Hydrogel Contact Lenses

    … associated with the lack of phospholipids in the tear film, leading to disruption of the tear film and subsequent irritation. Characterization of the transport and release of phospholipids from a silicone hydrogel contact lens is required to assess the possible use of these lenses for phospholipid …

    byu Repository record for Phospholipid Transport in Silicon Hydrogel Contact Lenses (opens in a new tab) Download PDF for Phospholipid Transport in Silicon Hydrogel Contact Lenses (opens in a new tab)

  2. Olhos no futuro: Lentes de hidrogel de PVA abrindo caminho para a administração ocular de anfotericina B

    … or molecular dispersed state. After 30 days in artificial tear fluid (pH ~ 7.4), the lenses exhibited low mass loss (4.4 ± 2.7%), supporting their structural stability. Release studies demonstrated a sustained and controlled AmB release profile, with cumulative release ranging from approximately …

    brazil-ufrn Repository record for Olhos no futuro: Lentes de hidrogel de PVA abrindo caminho para a administração ocular de anfotericina B (opens in a new tab)

  3. The HLD Framework for Complex Fluids with Polydisperse Nonionic Surfectants

    … mildness and low toxicity. To design complex fluids such as microemulsions and micelle-laden ionotropic hydrogels, it is important to understand the hydrophilic-lipophilic nature of these surfactants and their impact on the surfactant-oil-water (SOW) and surfactant-water (SW) phase behavior. …

    toronto-retro Repository record for The HLD Framework for Complex Fluids with Polydisperse Nonionic Surfectants (opens in a new tab)

  4. Comfort and Compatibility of Silicone Hydrogel Contact Lenses

    … to lipid removal. An in vitro model using an artificial tear fluid containing radiolabeled lipids was employed in this thesis research to evaluate the efficacy of different multi-purpose lens care solutions in removing lipids from SiHy contact lenses. Additional rubbing with the lens care …

    byu Repository record for Comfort and Compatibility of Silicone Hydrogel Contact Lenses (opens in a new tab) Download PDF for Comfort and Compatibility of Silicone Hydrogel Contact Lenses (opens in a new tab)

  5. Towards abiotic glucose fuel cells as powering concepts for medical implants and sensors

    … supply would become obsolete. However, body-fluid constituent as for instance amino acids poison the anode’s surface and drastically diminish the performance and lifetime of the glucose fuel cell. Furthermore, the power outputs of abiotic glucose fuel cells are low compared to commonly used …

    freiburg-diss Repository record for Towards abiotic glucose fuel cells as powering concepts for medical implants and sensors (opens in a new tab)