Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 221 for “"atom probe tomography"”.
-
Atom probe tomography of irradiated zirconium alloys
… to quantify. This project was carried out using atom probe tomography (APT) to quantify the nanoscale changes to the alloy chemistry in a Zr-2.5Nb pressure tube alloy before and after irradiation. A key aim was to quantify the solute niobium and iron concentration left behind in the α-Zr matrix …
-
Model-driven reconstruction in atom probe tomography
… new continuum model for predicting results from atom probe tomography (APT) experiments. Unlike previous atomic-scale approaches, this continuum approach makes realistic specimen simulation computationally tractable, enabling direct quantitative comparison with experiment. Here, specimen …
-
Atom probe tomography characterization of engineering ceramics
… of techniques with a particular emphasis on atom probe tomography (APT).</p> <p>Laser assisted APT, as applied to the analysis of ceramics, is a relatively nascent technique, so optimal operating conditions for the subject materials were rigorously investigated. A systematic and reproducible …
-
Developing Modern Atom Probe Tomography for Nonmetals
Atom probe tomography as a 3D atomic-scale characterization tool has seen considerable development in the past decade, both in systems improvement and theoretical understanding. However, the time and expertise required from the outset of experimentation to analyzed results is highly asymmetric …
-
Quantitative chemical imaging in atom probe tomography
<p>Atom Probe Tomography (APT) resolves atoms in real space and detects their chemical identity. In the realm of microscopic techniques, it has its unique place with sub nanometer spatial resolution and high chemical sensitivity. In this thesis, data driven techniques have been developed to …
-
Atom probe tomography of crystallographic defects in silicon
… electron back scatter diffraction (EBSD) and atom probe tomography (APT). This approach combines the characterisation of recombination activity, crystallographic information, and chemical composition of individual defects after various stages of processing. These methods were employed to …
-
Rigorous nonlinear electrostatic simulation of atom probe tomography
Laser-assisted atom probe tomography (L-APT) is a field driven microscopic technique that can provide sub-nm atomic mapping of solid materials at ppm-level sensitivity and has been successfully used to analyze the nano-structures of metals, semiconductors, and dielectrics. In APT, the specimen is …
-
Advancing Atom Probe Tomography: Multiscale Modelling and Simulation
Atom Probe Tomography (APT) is a powerful technique for three-dimensional compositional imaging at near-atomic resolution. While extensively applied to metals and alloys, its extension to biological systems remains challenging due to difficulties in sample preparation, the insulating nature of …
-
Atom probe tomography study of wide bandgap semiconductor materials
This dissertation focuses on developing atom probe tomography (APT) for semiconductors. APT is quickly gaining interest in the field of material characterization because of its unique ability to provide 3D nanoscale studies. APT has been widely used in metals and conductive materials but design …
-
Atom probe tomography research on catalytic alloys and nanoparticles
… </p> <p>This work presents a study utilising atom probe tomography (APT), combined with an in-situ reaction cell, to understand the initial oxidation processes of catalytic NiFe and NiCo model alloy systems. In order to improve reliability of results, a protocol was developed to clean the …
-
Understanding proton-conducting perovskite interfaces using atom probe tomography
… the ceramic. This thesis applies laser-assisted atom probe tomography (LAAPT) to provide new insights into the GB chemistry and resulting space-charge behavior of BaZr0.9Y0.1O3−δ (BZY10), a prototypical proton-conducting ceramic. LAAPT is an exciting characterization technique that allows for …
-
Atom probe tomography of small-molecule organic semiconducting materials
… for these materials. This work demonstrates that atom probe tomography (APT) is well-suited to this purpose. It can provide sub-dalton mass resolution, detection thresholds of less than 100 ppm, and spatial distribution of molecules with better than nanometer precision. These capabilities mean …
-
New stochastic and computational approaches in atom probe tomography
Atom probe tomography (APT) provides quantitative three-dimensional compositional mapping of materials with near-atomic spatial resolution and parts-per-million chemical sensitivity, thereby enabling fundamental insights into material nanostructures and properties. However, despite these …
-
Characterisation of hydrogen trapping in steel by atom probe tomography
… of freely diffusing hydrogen within the metal atomic lattice via the introduction of microstructural hydrogen traps. Further, it is empirically known that the introduction of finely-dispersed distribution of nano-sized carbide hydrogen traps in ferritic steel matrix can improve resilience to …
-
Developing atom probe tomography for unique nanoscale insights into biomaterials
… of 3D spatial structure and the mapping of low atomic mass elements.</p> <p>Among the many synthetic bone substitutes, bioactive glasses (BG) are an attractive candidate with applications in critical bone damage repair, as they stimulate biological responses that favor bone formation and …
-
Sample preparation technique development for atom probe tomography of nanoparticles
Atom Probe Tomography (APT) can produce 3D chemical analysis on the atomic scale and there is an increasing interest for the analysis of nanoparticles (NPs). In the past there has been limited success with special geometry and non-bulk nanomaterials. In this work several APT sample preparation …
-
Atom Probe Tomography for Modelling Eigenstates in a Quantum Dot Ensemble
… of many optoelectronic devices. In this thesis, atomic force microscopy, transmission electron microscopy, and atom probe tomography (APT) are used to assess and compare QD size and core concentration. APT by means of isosurface reconstruction provides the most accurate ensemble averaged quantum …
Page 1 of 12