Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 34 for “"attenuation length"”.

  1. Feasibility of acoustic neutrino detection with the South Pole Acoustic Test Setup

    … large neutrino telescopes is dictated by the attenuation length of the observable signal that is generated by the neutrino interaction with the medium. The optically transparent ice at the geographic South Pole has optical attenuation lengths in the order of 100m. This has allowed the …

    ghent Repository record for Feasibility of acoustic neutrino detection with the South Pole Acoustic Test Setup (opens in a new tab)

  2. Skaidulinių scintiliatorių optinių savybių tyrimas /

    … was approximately 543nm. Furthermore, the attenuation length of the samples was also measured. A special stand was made to carry out this experiment. A sample was placed on the rail to which a fiber optic was attached on one side. In this way, we were able to measure the photoluminescence …

    vilnius Repository record for Skaidulinių scintiliatorių optinių savybių tyrimas / (opens in a new tab)

  3. Acoustic properties of the South Pole ice for astrophysical neutrino detection

    … acoustic detection in ice so far. The acoustic attenuation length of the Antarctic ice is a fundamental quantity to design a future acoustic neutrino detector at the South Pole. The longitudinal waves in the South Pole ice are expected to be attenuated via absorption and scattering, where the …

    ghent Repository record for Acoustic properties of the South Pole ice for astrophysical neutrino detection (opens in a new tab)

  4. Bulk and Surface Radio-Frequency Response of Ice

    … observed by Antarctic detectors, the bulk attenuation and surface reflection properties of Antarctic ice must be estimated. Neutrino experiments that intend to use polar ice as the detector volume must consider the depth-dependent attenuation length of the ice. Airborne experiments, such as …

    ku Repository record for Bulk and Surface Radio-Frequency Response of Ice (opens in a new tab)

  5. Experimental and theoretical aspects of high energy neutrino astrophysics

    … of a photomultiplier array, based on the water attenuation length results. The question of energy discrimination is also examined.

    adelaide Repository record for Experimental and theoretical aspects of high energy neutrino astrophysics (opens in a new tab)

  6. Measurement and simulation of extreme ultraviolet ablation of solids

    … nm. The increased photon energy at these wavelengths enables photo-ionization and increases the critical density above solid density; setting EUV ablation apart from optical wavelength ablation. Experimental ablation features on aluminium, gold, and copper targets are created by focussing …

    whiterose Download PDF for Measurement and simulation of extreme ultraviolet ablation of solids (opens in a new tab)

  7. Low energy electron attenuation lengths in thin amorphous carbon films

    … energies between 50 and 3000 eV, electron attenuation lengths were determined by electron transmission measurements through carbon o films of thicknesses between 81 and 210 A. The density of amorphous carbon was also obtained by a sink-float method and found to be 1.90 ± 0.05 …

    ut-knoxville Repository record for Low energy electron attenuation lengths in thin amorphous carbon films (opens in a new tab)

  8. Optimization of Scintillator Performance for the Development of Large Scale Scintillation Detector

    … to maximise the light yield and optical attenuation length, thus giving optimum energy resolution and detection efficiency of the LS veto detector. In this study, the service lifetime of Viton O-rings, required as seals in the detector, were examined under different ageing temperatures …

    unsw Repository record for Optimization of Scintillator Performance for the Development of Large Scale Scintillation Detector (opens in a new tab)

  9. Numerical simulations of shockless nonlinear acoustic noise in one dimension

    The attenuation of a monochromatic signal in the presence of discrete noise in one dimension is investigated numerically. The predicted Gaussian attenuation is verified by the numerical program, which is based on Riemann's implicit solution of the exact equation for the unidirectional propagation …

    nps Repository record for Numerical simulations of shockless nonlinear acoustic noise in one dimension (opens in a new tab)

  10. Physical properties of liquid scintillators

    … 0°C and 25°C. They must also maintain a stable attenuation length at 0°C comparable to their attenuation length at ambient near surface conditions, between 20°C and 25°C.

    hawaii Repository record for Physical properties of liquid scintillators (opens in a new tab)

  11. Optical Calibration of the SNO+ Detector using Internal Backgrounds

    … over a period of time at a fixed set of wavelengths, allowing the photomultiplier tube responses and attenuations of the three detector media (scintillator, acrylic and ultra-pure water) to be extracted via an optical model. This thesis presents a method to extract an effective attenuation …

    queens Repository record for Optical Calibration of the SNO+ Detector using Internal Backgrounds (opens in a new tab)

  12. Simulations of Radiatively Driven Convection and Spatially Heterogeneous Solar Radiation Intensity in Ice-Covered Lakes

    … where the albedo change, initial temperature and attenuation length are varied. The Albedo change only affects the development of the intrusion, whereas the initial temperature and attenuation length both affect the development of the intrusion and the radiatively driven convection away from the …

    waterloo Repository record for Simulations of Radiatively Driven Convection and Spatially Heterogeneous Solar Radiation Intensity in Ice-Covered Lakes (opens in a new tab)

  13. 16N calibration and background studies for SNO+

    … model that I have used to estimate the effective attenuation length of the detector in scintillator phase. The model was used to fit the tagged 214Po events in scintillator phase, and estimate the effective attenuation length. The result is consistent with other studies. Moreover, chapter 7 …

    laurentian Repository record for 16N calibration and background studies for SNO+ (opens in a new tab)

  14. Studies of paramagnetic metal surfaces and thin films using spin-sensitive electron spectroscopies

    … was employed as a signature to determine the attenuation length for low energy electrons in molybdenum. When molybdenum thin films were grown on a Cu(100) substrate, the Mo loss feature becomes prominent upon deposition of only one monolayer.

    rice Repository record for Studies of paramagnetic metal surfaces and thin films using spin-sensitive electron spectroscopies (opens in a new tab)

  15. Cosmogenic nuclides as a surface exposure dating tool: improved altitude/latitude scaling factors for production rates

    … monitor survey. Our data confirm that the attenuation length is energy dependent and suggest that the scaling factor for energetic nucleons is 10% higher between sea level and 4000 m than for low-energy neutrons at this location. An altitude profile of cosmogenic 36Cl production from lava …

    arizona-thes Repository record for Cosmogenic nuclides as a surface exposure dating tool: improved altitude/latitude scaling factors for production rates (opens in a new tab)

  16. High-resolution spectro-microscopic investigations of organic thin film growth

    … imaging properties are discussed. The effective attenuation length is determined for the photoemission of low energy electrons. The geometric phase contrast in electron reflectivity is found also at the substrate steps buried under PTCDA layers. The first imaging of the quantum size effect in …

    fu-berlin Repository record for High-resolution spectro-microscopic investigations of organic thin film growth (opens in a new tab)

  17. Tuning neutrino interaction models to inclusive electron scattering data

    … feedback on the detector’s water quality. Attenuation measurements using a diffuser installed in the top of the tank are also implemented, the first analysis completed from the UKLI system, and compared to current, independent methods. This measurement allows for sensitive monitoring of the …

    whiterose Download PDF for Tuning neutrino interaction models to inclusive electron scattering data (opens in a new tab)

  18. A Study of Extreme Ultraviolet Capillary Discharge Lasers and the Ablation of Solid Targets

    … produces a pulse of duration 1.2ns, at a wavelength of 46.9nm, with a repetition rate of up to 10Hz. A review of EUV production and the optical properties of EUV radiation at 46.9nm is given. From this a review of potential focusing methods for the laser is presented. An on-axis spherical …

    whiterose Download PDF for A Study of Extreme Ultraviolet Capillary Discharge Lasers and the Ablation of Solid Targets (opens in a new tab)

  19. Two dimensional electron gas at oxide interfaces

    … The confinement width is then determined by the attenuation length of the metal induced gap states into SrTiO3 which is governed by the lowest decay rate evanescent states of bulk SrTiO3 which in turn can be found from the complex band structure of bulk SrTiO3. Magnetic properties of the 2DEG …

    nebraska Repository record for Two dimensional electron gas at oxide interfaces (opens in a new tab)

  20. Optical studies of three dimensional confinement in photonic and electronic systems.

    … calculated one, and also the experimental Bragg attenuation length is found to be five to seven times larger than the calculated one. Angle resolved diffraction and scattering techniques are used to investigate the origin of the discrepancies between experiment and theory. Analysis of the …

    whiterose Download PDF for Optical studies of three dimensional confinement in photonic and electronic systems. (opens in a new tab)

Page 1 of 2