Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 21 for “"attenuation measurement"”.
-
Optical Fiber Attenuation Measurement
… for establishing accurate and precise measurement techniques of these properties. The optical loss is the most important parameter characterizing fiber. This project reviews the subject of loss (or attenuation), its measurement and some of its subtleties. </p> <p> Presently at BNR there …
-
Attenuation measurement by ultrasonic techniques
Thesis (M.S.)--Michigan State University. Department of Electrical Engineering and System Science, 1987
-
Investigation of physical and psychophysical methods for the attenuation measurement of circumaural hearing protectors with implication for field use
… measure is needed to estimate the attenuation workers are achieving with their hearing protectors in the field. Alternative measures for assessing a hearing protector's effectiveness were evaluated through comparison to the standardized real-ear attenuation at threshold (REAT) …
-
Determination of seismic attenuation from surface and downhole measurements.
Intrinsic attenuation measurement from VSP using spectral ratios is seriously affected by scattering, coupling variations, and difficulties in first-arrival isolation. An algorithm to estimate intrinsic attenuation from VSP data where reliable seismic impedance logs are available effectively …
-
Development of a diver-deployed instrument for the measurement of sediment density gradients by X-ray attenuation measurements
… these methods are unable to provide direct measurements of the sediment density gradient without significantly disrupting the test site and requiring significant diver support for installation and implementation. The proposed X-Ray Attenuation Measurement (XRAM) device aims to improve upon …
-
MODELING AND MEASUREMENT OF ATTENUATION IN SYNTHETIC SEISMIC DATASETS
… the Earth. These phenomena are known as seismic attenuation. The associated physical processes lead to reduced amplitudes, waveform distortions, and phase delays of seismic wave arrivals. Seismic wave attenuation is often viewed as an important indicator of the presence of fluids, variations of …
-
Design, Fabrication and Characterization of a Polymer Electro-Optic Modulator
… the waveguide. The other new method is for the attenuation measurement of polymer waveguides – we fabricate waveguides of different lengths on one substrate and characterize the attenuation by plotting the output power of these waveguides as a function of the propagation lengths.
-
Acoustic emission monitoring of concrete structures using waveguides.
… to overcome the difficulty of high acoustic attenuation in concrete. Solid embedded waveguides, liquid-filled embedded waveguides and solid surface waveguides have been developed in this study. An analytical model of a waveguide with infinitely thick cladding was used to study the wave …
-
Evaluation and Mitigation of Industrial Fire Hazards
… uncertainties involved when transforming light attenuation measurements into soot volume fraction. Simulations of tests according to the EN54 detector standard were also carried out. The agreement differed for different fuels. In addition, there is a problem with comparing light attenuation …
-
Measurement and modelling of human presence, through-wall attenuation and link diversity at millimetre-wave frequencies
… characterize the manner in which through-wall attenuation varies between wall types, different walls of the same type, and different locations on a given wall together with an indication of how these results scale between 10 and 30 GHz; and 3) to provide an accurate assessment of the relative …
-
Measurement of Dust Cloud Dynamics in a Standard Minimum Ignition Energy Device
… device against its MIKE3 counterpart via light attenuation measurement of relative concentration.
-
Development and application of spread-spectrum ultrasonic evaluation technique
… like, flaw detection, velocity/thickness measurements, attenuation measurement, global integrity assessment, etc., was investigated through various laboratory experiments. It is concluded that the SSUE technique holds great promise for all ultrasonic NDE applications where high signal …
-
Nonlinear Ultrasonic Non-Destructive Evaluation: Understanding the limitations and improving the metrology of nonlinear ultrasound
… linear ultrasonic method such as wave speed, attenuation measurement or imaging using total focusing method. In contrast to common linear ultrasonic techniques, signals from NUT are orders of magnitude smaller compared to its linear counterpart. This thesis explores the limitations of certain …
-
Optical waveguide measurements of reactive low voltage ion plated thin films
… understood yet / Gue90b/. I will discuss the measurements made on RL VIP films of four materials: Ti 02, Ta2O5 , A12O3 , and Si 02• The measurements are part of an effort to improve the quality of the coatings made by the RLVIP process. I used a waveguide approach to measure the index of …
-
Měření útlumu ultrazvukového vlnění
Tato diplomová práce se zabývá způsoby měření útlumu ultrazvuku. V rámci práce jsou navrženy a proměřeny různé metody měření útlumu. Jako referenční látka pro toto měření je použit ricinový olej. Pro měření jsou využity různé ultrazvukové měniče, hydrofon a ultrazvukový zobrazovací systém GE …
-
Design and Fabrication of Optomechanical Formalin Fixation Monitoring Systems Integrated with a Millifluidic Device
… technique for SW visualization and velocity measurement, and the SW-LSI system consisting of a 532nm laser, a piezo-actuator and a camera was constructed for this study. The stiffness changes of phantoms and chicken breast tissues during formalin fixation are investigated for different sizes …
-
Experimentální ultrazvuková měření pomocí LabView
Tato bakalářská práce se zabývá ultrazvukovým polem, měřením jeho útlumu a měřením pomocí LabVIEW. Jsou zde vysvětleny základní parametry ultrazvukových měničů a ultrazvukového pole. Byly navrženy dvě metody pro měření útlumu a modifikace té druhé. V této práci jsou uvedeny dva programy v LabVIEW …
-
Testování přenosových vlastností vícejádrových optických vláken
Tato bakalářská práce se zabývá problematikou vícejádrových optických vláken a měřením jejich přenosových vlastností. První část se krátce věnuje obecně optickým vláknům, dále podrobně rozebírá vícejádrové optické vlákna, jejich přenosové vlastnosti, techniku přenosu, metody spojování a metody …
-
Generátor kalibračního pulzního signálu
Tato diplomová práce je věnována seznámení se spektrálními vlastnostmi impulzů, měřícími principy, které využívají hřebenové generátory a možnostmi generování impulzů v sub-nanosekundové oblasti, kde jednotlivé topologie jsou krátce představeny. Podrobně jsou porovnány metody využití lavinových …
Page 1 of 2