Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 183 for “"attenuator"”.

  1. Passive hand tremor attenuator : magnetic spring

    It is known that Parkinson’s disease is a progressive disorder of the nervous system that has a significant impact on body movement. Symptoms of the disease begins with a barely noticeable tremor of the hands. Though Parkinson’s disease is mostly recognizable by the tremors it causes on the …

    ubc Repository record for Passive hand tremor attenuator : magnetic spring (opens in a new tab) Download PDF for Passive hand tremor attenuator : magnetic spring (opens in a new tab)

  2. SOI RF-MEMS Based Variable Attenuator for Millimeter-Wave Applications

    … pull towards millimeter-wave devices. Variable attenuators are widely employed for adjusting signal levels in high frequency equipment. RF circuits such as automatic gain control amplifiers, broadband vector modulators, full duplex wireless systems, and radar systems are some of the primary …

    waterloo Repository record for SOI RF-MEMS Based Variable Attenuator for Millimeter-Wave Applications (opens in a new tab)

  3. Design Of A Truck-Mounted Attenuator With Tube Folding Technology

    DESIGN OF A TRUCK-MOUNTED ATTENUATOR WITH TUBE FOLDING TECHNOLOGY SANTOSH GAUTAM MECHANICAL ENGINEERING ABSTRACT Highway safety features have been continuously developed and employed over the years to protect vehicle occupants, pedestrians and work zone personnel from injuries in roadside …

    uab Repository record for Design Of A Truck-Mounted Attenuator With Tube Folding Technology (opens in a new tab)

  4. Development of efficient finite element model for Truck Mounted Attenuator

    … research areas in engineering. Truck Mounted Attenuators are used to protect motorists, workers, and equipment from road accidents. Usually they consist of an energy absorption cushion and lift up unit called the docking station which is used for mobile carrier attachment. In case of …

    nebraska Repository record for Development of efficient finite element model for Truck Mounted Attenuator (opens in a new tab)

  5. Evaluation of an autonomous truck mounted attenuator system in work zones

    … errant vehicles crashing into the truck mounted attenuator (TMA) that protects the workers. To reduce worker (i.e., operator) injuries in TMA crashes, a few state DOTs have conducted research and development of an autonomous system that removes the driver from the follower TMA. The objective of …

    missouri Repository record for Evaluation of an autonomous truck mounted attenuator system in work zones (opens in a new tab)

  6. Using Commercial Ray Tracing Software to Drive an Attenuator-Based Mobile WIreless Testbed

    We propose and build a prototype architecture for a laboratory-based mobile wireless testbed that uses highly detailed, site-specific channel models to dynamically configure a many-to-many analog channel emulator. Unlike similar systems that have used abstract channel models with few details from …

    maryland Repository record for Using Commercial Ray Tracing Software to Drive an Attenuator-Based Mobile WIreless Testbed (opens in a new tab)

  7. Design of Chassis, Impact Attenuator, Suspension and Aerodynamic Systems of a Formula SAE Car

    … an attempt made to design the chassis, impact attenuator, aerodynamics and suspension systems of the first UH College of Technology Formula SAE car. A systematic design methodology was adopted to tackle the challenge of having many unavailable inputs while designing each subsystem. The …

    houston Repository record for Design of Chassis, Impact Attenuator, Suspension and Aerodynamic Systems of a Formula SAE Car (opens in a new tab)

  8. Modeling, design, and evaluation of a novel passive hand tremor attenuator for broadband suppression

    … non-linear multi-degree-of-freedom (MDOF) attenuator. Through dynamic modeling of the human arm complex at the musculoskeletal level, coupled with iterative refinement of the device through rigorous experimental evaluation, the final prototype demonstrates significant efficacy in reducing …

    ubc Repository record for Modeling, design, and evaluation of a novel passive hand tremor attenuator for broadband suppression (opens in a new tab) Download PDF for Modeling, design, and evaluation of a novel passive hand tremor attenuator for broadband suppression (opens in a new tab)

  9. COMPREHENSIVE REVIEW AND DEVELOPMENT OF A HIGH-PRESSURE HYDRAULIC IMPEDANCE TUBE FOR VIBROACOUSTIC ATTENUATOR CHARACTERIZATION

    … bench for characterizing hydraulic vibroacoustic attenuators. The primary evaluation metric is the transfer matrix, determined experimentally, with an emphasis on key properties such as transmission loss. To ensure accuracy and broad applicability, the methodology is based on industry-standard …

    mtu Repository record for COMPREHENSIVE REVIEW AND DEVELOPMENT OF A HIGH-PRESSURE HYDRAULIC IMPEDANCE TUBE FOR VIBROACOUSTIC ATTENUATOR CHARACTERIZATION (opens in a new tab)

  10. Novel Segment Deformable Mirror Based Adaptive Attenuator Used In Wavelength Division Multiplexed Optical Communications Network

    … at each wavelength is needed. An adaptive attenuator is a device with a chromatically variable transmissivity used to equalize channel powers in wavelength-division multiplexing (WDM) fiber-optic communication lines. In this thesis, a method of Fourier analysis of multi-beam interference is …

    vt Repository record for Novel Segment Deformable Mirror Based Adaptive Attenuator Used In Wavelength Division Multiplexed Optical Communications Network (opens in a new tab)

  11. Mechanistic and Functional Characterization of B and T Lymphocyte Attenuator (Btla) In Cd8 Tumor Infiltrating Lymphocytes

    … co-inhibitory molecule BTLA (B-and-T lymphocyte attenuator) was highly associated with clinical response, while expression of other co-inhibitory molecules such as PD-1, TIM-3, and Lag3 did not associate with response. BTLA is expressed by T cells, B cells, and NK cells and serves as a T cell …

    uthsc Repository record for Mechanistic and Functional Characterization of B and T Lymphocyte Attenuator (Btla) In Cd8 Tumor Infiltrating Lymphocytes (opens in a new tab)

  12. Characterization of A transcriptional Attenuator in The rpmf-Plsx-Fab Operon of Escherichia coli K-12

    … that a weak transcriptional terminator (an attenuator) lies at the 5' end of plsX. The attenuator was localized to a 200 bp segment. Analysis of the secondary structure of the attenuator mRNA has lead to a model which includes four stem-loop structures. In this model, the plsX start codon …

    vt Repository record for Characterization of A transcriptional Attenuator in The rpmf-Plsx-Fab Operon of Escherichia coli K-12 (opens in a new tab)

  13. Analysis of a Carbon Fiber Reinforced Polymer Impact Attenuator for a Formula SAE Vehicle Using Finite Element Analysis

    The Hashin failure criteria and damage evolution model for laminated fiber reinforced polymers are explored. A series of tensile coupon finite element analyses are run to characterize the variables in the physical model as well as modeling techniques for using an explicit dynamic solver for a …

    calpoly Repository record for Analysis of a Carbon Fiber Reinforced Polymer Impact Attenuator for a Formula SAE Vehicle Using Finite Element Analysis (opens in a new tab)

  14. Design and analysis of an attenuator-based, four-channel, differential, 150 MHz, linear-in-dB VGA with sub-nanosecond delay dispersion for PET applications

    <p>Positron Emission Tomography (PET) is a medical imaging methodology based on the measurement of the concentrations of a positron-emitting radioisotope inside a three dimensional object. PET systems require hundreds of channels of high perfonnance detector readout electronics. The Phase I ASIC …

    utk-theses Repository record for Design and analysis of an attenuator-based, four-channel, differential, 150 MHz, linear-in-dB VGA with sub-nanosecond delay dispersion for PET applications (opens in a new tab)

  15. Design and analysis of an attenuator-based, four-channel, differential, 150 MHz, linear-in-dB VGA with sub-nanosecond delay dispersion for PET applications

    <p>Positron Emission Tomography (PET) is a medical imaging methodology based on the measurement of the concentrations of a positron-emitting radioisotope inside a three dimensional object. PET systems require hundreds of channels of high perfonnance detector readout electronics. The Phase I ASIC …

    utk-theses Repository record for Design and analysis of an attenuator-based, four-channel, differential, 150 MHz, linear-in-dB VGA with sub-nanosecond delay dispersion for PET applications (opens in a new tab)

  16. Investigating Additional Roles of the trp RNA-Binding Attenuation Protein (TRAP) in Transcriptional Regulation of the trp Operon in Bacillus subtilis

    … RNA structures, the antiterminator and the attenuator. TRAP binding precludes antiterminator formation, which allows the attenuator to form. The attenuator was presumed to act as an intrinsic terminator. However, previous data show that the attenuator is not able to induce transcription …

    buffalo Repository record for Investigating Additional Roles of the trp RNA-Binding Attenuation Protein (TRAP) in Transcriptional Regulation of the trp Operon in Bacillus subtilis (opens in a new tab)

  17. Ultra-low phase noise 100 MHz crystal oscillator & residual phase noise measurement systems

    … and it is shown how the placement of an attenuator between the resonator and the input of the amplifier in an oscillator loop can be used as a simple way to reduce phase noise degradation in certain circumstances. A set of digitally-controlled phase shifter and attenuator devices are …

    whiterose Download PDF for Ultra-low phase noise 100 MHz crystal oscillator & residual phase noise measurement systems (opens in a new tab)

Page 1 of 10