Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 27 for “"average deviations"”.

  1. Spectroscopic study of channel spectra phenomena in the synchrotron-based FTIR spectrometer at the Canadian Light Source

    … were retrieved for 48 spectral lines with average deviations from HITRAN database values of 2.11%, 1.25% and 4.14%, respectively, using the Voigt profile. These average deviations lie within the uncertainty limits listed by the database. The deviation between our results and other results …

    lethbridge Repository record for Spectroscopic study of channel spectra phenomena in the synchrotron-based FTIR spectrometer at the Canadian Light Source (opens in a new tab)

  2. Accuracy of Implants Placed with Surgical Guides: Thermoplastic vs. 3-D Printed

    … the control implant were superimposed to measure deviations. Results: The thermoplastic group showed average deviations of 3.4 degrees, 1.3mm at the head, and 1.6mm at the apex of the implant compared to 2.36 degrees, 0.51mm, and 0.76mm for the 3-D printed group; p= 0.143, p<0.001, and p<0.001 …

    loma-linda Repository record for Accuracy of Implants Placed with Surgical Guides: Thermoplastic vs. 3-D Printed (opens in a new tab)

  3. Modeling Inter-plant Interactions

    … and compared to each other along with the average deviations in each of the five regions. Analysis of the five separate regions aided in the creation of different growth equations that each encompassed all of the regions together. Four different growth equations are developed and then …

    ucf Repository record for Modeling Inter-plant Interactions (opens in a new tab)

  4. Efficient routing of snow removal vehicles

    … annealing heuristic was able to achieve average improvements of up to 26.36% over the construction results on these problem instances. The results obtained with the developed heuristic were compared to the results obtained with recent heuristics developed by other authors. The developed …

    wvu Repository record for Efficient routing of snow removal vehicles (opens in a new tab)

  5. Modelagem, simulação e otimização do processo de desidratação catalítica do etanol a etileno em diferentes escalas

    … for different conditions and campaigns, with average deviations of less than 5% for the reactor temperature profiles and 10% for the main components. Finally, the concept of the proposed industrial process was simulated and evaluated economically, being optimized for different capacities, …

    brazil-uerj Repository record for Modelagem, simulação e otimização do processo de desidratação catalítica do etanol a etileno em diferentes escalas (opens in a new tab)

  6. Investigating Spring Dead Spot Management via Aerial Mapping and Precision-Guided Inputs

    … and to 2017 SDS incidence maps, with average deviations of 1.3 m, 1.6 m, and 0.1 m, respectively. Digital Image Analysis (DIA) of aerial maps was compared to a point-intersect method for validation with a significant linear relationship (r2 = 0.77, P ≤ 0.0001). In the fall of 2016 and …

    vt Repository record for Investigating Spring Dead Spot Management via Aerial Mapping and Precision-Guided Inputs (opens in a new tab)

  7. Partial Upgrading of Bitumen Through Combinations of Deasphalting and Visbreaking

    … matched the product compositions with averge deviations of 1-3 wt%, depending on the fraction. The product density and viscosity were matched with average deviations of 3.0 kg/m³ and 44%, respectively. The onset of asphaltene precipitation (stability) was matched with an average deviation of …

    calgary Repository record for Partial Upgrading of Bitumen Through Combinations of Deasphalting and Visbreaking (opens in a new tab)

  8. Delayed critical unreflected and unmoderated uranium metal single cylinder and interacting cylinders (two) for evaluation of a neutron transport method and associated cross-section data

    … being Δke<sub><em>eff</em></sub>= ± 0.0062. The average deviations of ke<sub><em>eff</em></sub> values obtained with the Hansen- Roach, 27-group, and 238-group cross-section libraries from the measured values are - 0.0021, +0.0039, and -0.0042, respectively. With impurities explicitly modeled …

    ut-knoxville Repository record for Delayed critical unreflected and unmoderated uranium metal single cylinder and interacting cylinders (two) for evaluation of a neutron transport method and associated cross-section data (opens in a new tab)

  9. Characterization of structured packing via computational fluid dynamics

    … geometry produced via X-ray CT scans showed average deviations less than 15% when compared to experimental measurements. This error was reduced to 7% when a mesh utilizing prism layers to accurately resolve the boundary layer was used. With a validated model for single phase flow, the …

    texas Repository record for Characterization of structured packing via computational fluid dynamics (opens in a new tab)

  10. Multivariate analyses of near-infrared and UV spectral data.

    … optimized method was able to predict PMI with an average deviation of six days. A brief field study was also conducted and yielded similar results. The second study relates to a present analytical encumbrance faced by the pharmaceutical industry, namely assuring the enantiomeric purity of chiral …

    baylor Repository record for Multivariate analyses of near-infrared and UV spectral data. (opens in a new tab)

  11. Determining the surface tension of gas-liquid interfaces through metadynamics

    … experiment are in very good agreement and have average deviations of 4.1%, 1.6% and <0.1% respectively when compared to experimental γ<sub>GL</sub> values. Further work in studying this method can investigate a wider range of reduced temperatures T<sup>*</sup>, different systems such as water, …

    qu-belfast Repository record for Determining the surface tension of gas-liquid interfaces through metadynamics (opens in a new tab) Download PDF for Determining the surface tension of gas-liquid interfaces through metadynamics (opens in a new tab)

  12. THERMODYNAMIC AND TRANSPORT PROPERTIES OF AVIATION TURBINE FUEL: PREDICTIVE APPROACHES USING ENTROPY SCALING GUIDED MACHINE LEARNING WITH EXPERIMENTAL VALIDATION

    … Model performance against test data showed average deviations of 0.1%, 1%, and -2% for viscosity, thermal conductivity, and specific heat respectively. Utilizing the compositional data collected, the models were then used to estimate bounds of these properties. Analysis of Prandtl numbers …

    maryland Repository record for THERMODYNAMIC AND TRANSPORT PROPERTIES OF AVIATION TURBINE FUEL: PREDICTIVE APPROACHES USING ENTROPY SCALING GUIDED MACHINE LEARNING WITH EXPERIMENTAL VALIDATION (opens in a new tab)

  13. A Prediction Model for Adiabatic and Diabatic Capillary Tubes with Alternative Refrigerants

    … tubes/suction line heat exchangers. The average deviations of the specific refrigerant correlations range from 1.27% to 6.30% for both the adiabatic capillary tube and heat exchanger. The deviation of the generalized correlation is 1.91% for adiabatic capillary tubes with subcooled inlet …

    tamu Repository record for A Prediction Model for Adiabatic and Diabatic Capillary Tubes with Alternative Refrigerants (opens in a new tab)

  14. Extração do óleo e caracterização dos resíduos da borra de petróleo para fins de reuso

    … in the oil extraction process was 70%, in average. Oil sludge is composed of 36,2% of oil, 16,8% of ash, 40% of water and 7% of volatile constituents. However, the statistical analysis showed that the quadratic model was not well fitted to the process with a relative low determination …

    brazil-ufrn Repository record for Extração do óleo e caracterização dos resíduos da borra de petróleo para fins de reuso (opens in a new tab)

  15. An experimental study of a smart radiator device (SRD) for enhanced passive thermal control of satellites

    … my required 10C error margin, with maximum and average deviations of 7.21C and 3.57C respectively. The testing experience also led me to develop a set of best practices for TVAC testing small satellite components. To evaluate the SRD performance I created thermal math models and simulations of …

    manitoba Repository record for An experimental study of a smart radiator device (SRD) for enhanced passive thermal control of satellites (opens in a new tab)

  16. Determination of Solubility Parameter of Methane in Heavy Oil

    … correlation matched the onsets and yields with average deviations of 1.1 wt% solvent and 8.1 wt%, respectively. The updated model now applies to in situ heavy oils that contain dissolved methane.

    calgary Repository record for Determination of Solubility Parameter of Methane in Heavy Oil (opens in a new tab)

  17. Comparison of Scanning Accuracy of PVS Impressions of Multiple Tooth Preparations with Different Tapers Using Two Benchtop Scanners: An In-Vitro Study

    … Geomagic Control X 2020 software. The absolute average deviation measured in µm were compared in a total of 16 subgroups relating to scanners, tooth locations and convergence angles. Three-way ANOVA and post-hoc Tukey HSD pairwise comparison tests were conducted. A non-parametric Kruskal-Wallis …

    buffalo Repository record for Comparison of Scanning Accuracy of PVS Impressions of Multiple Tooth Preparations with Different Tapers Using Two Benchtop Scanners: An In-Vitro Study (opens in a new tab)

  18. Field Evaluation of a Subsurface Irrigation Drainage System in North Central South Dakota

    … plots during 1986 and 1987. Standard error and average deviation were used to describe the variability between observed and model estimated water table depths. Standard errors ranged from 9.7 to 22.6 cm (4.0 to 8.9 in) and average deviations ranged from 7.6 to 18.5 cm (3.0 to 7.3 in). Model …

    sdstate Repository record for Field Evaluation of a Subsurface Irrigation Drainage System in North Central South Dakota (opens in a new tab)

  19. Desenvolvimento de um sistema de alta eficiência para geração de íons hipoclorito via fluxo de reciclo combinado com a produção de hidrogênio verde

    … (R² = 98.39%; adjusted R² = 96.79%), with average and maximum deviations of 0.219% and 2.418%, respectively. The response surface indicated an optimal operating region that allows maximizing ClO⁻ production (540–570 mg L⁻¹) while minimizing energy consumption. The modified system enhanced …

    brazil-ufrn Repository record for Desenvolvimento de um sistema de alta eficiência para geração de íons hipoclorito via fluxo de reciclo combinado com a produção de hidrogênio verde (opens in a new tab)

  20. An Investigation Of The Feasibility Of Making Radiometric Titrations Of Precipitation Reactions

    … performed a radiometric titration. Their average results agreed almost exactly with the accepted value. Their average deviations were of the same order of magnitude as the accuracy reported in many studies using radioisotopes of high activity. The effects of complexation and pli dependence …

    u-pacific Repository record for An Investigation Of The Feasibility Of Making Radiometric Titrations Of Precipitation Reactions (opens in a new tab)

Page 1 of 2