Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 6 of 6 for “"average intensity projection"”.
-
Effects of reference image selection on the alignment of free-breathing lung cancer patients during setup imaging: average intensity projection versus mid-ventilation
… purpose of this paper is to quantify if using an average intensity projection (AIP) scan or a 30% phase (mid-ventilation surrogate, MidV) scan as the reference image for patient position verification affects reproducibility of lung cancer patient alignment under free-breathing cone beam computed …
-
Method of visualisation influences accuracy of measurements in cone-beam computed tomography
… multiplanar reformatting (MPR), maximum intensity projection of the volume of interest (VOIMIP), and average intensity projection of the volume of interest (VOIAvIP). All radiological methods were tested for repeatability and compared with anatomical results for accuracy, and limits of …
-
The use of novel MRI techniques to assess antenatal lung development: a pilot study
… which are currently lacking, by generating average signal intensity from T2 weighted anatomical datasets. This thesis aims to assess pulmonary development using these techniques both in healthy fetuses, to evaluate normal pulmonary development across gestation, and assess for alterations in …
-
On Tumor Motion, Delineation Strategies, and Respiratory Induced Density Variations Associated with Stereotactic Lung Radiotherapy
… the 10 phase benchmark, followed by the Maximum Intensity Projection (MIP) approach, then Average Intensity Projection (AIP), and finally FB. For PTV structures based on the delineation of the single phase FB image set, we have shown even with 10 mm superior-inferior margin [5 mm axial] yields …
-
Optimization strategies for respiratory motion management in stereotactic body radiation therapy
… featuring: a native free-breathing 3DCT, an average intensity projection (AIP) as well as a maximum intensity projection (MIP), both obtained from the patient's 4DCT, and density overrides (DOs) in a 3DCT. This study has been carried out for 5 SBRT patients for three-dimensional conformal …
-
Program pro zobrazení a práci s objemovými daty
Práce souhrnně popisuje možnosti zobrazení objemových dat. Blíže se věnuje skalárnímu typu objemových algoritmů, který následně dělí na techniky nepřímého a přímého zobrazení objemových dat. Z nepřímých technik přibližuje metodu Marching Cubes. Přímé techniky dále člení na algoritmy triviální a …