Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 175 for “"axial resolution"”.
-
A fourdimensional microscope for single molecule studies in living cells using astigmatic axial resolution enhancement
… per second enables this.</p> <p>An astigmatic axial resolution enhancement approach has been implemented to allow tracking with high precision of single fluorescent proteins in real-time in three dimensions in a comparatively large volume. The high resolution in three spatial dimensions and one …
-
Frequency resolved cell sizes using optical coherence tomography
High resolution Optical Coherence Tomography (OCT) imaging is demonstrated using a superluminescent diode at 1290nm for detecting sizes of tissue cells. This system is fiber-based, built around a Michelson Interferometer. A high speed optical delay line utilizing a resonant scanning mirror at 4kHz …
-
The Effects of Refractive Index Mismatch on Multiphoton Fluorescence Excitation Microscopy of Biological Tissue
… spherical aberration on signal attenuation and resolution degradation with depth are characterized with minimal light absorption and scattering using sub-resolution microspheres mounted in test sample of agarose with varied refractive index. The effects of light scattering on signal attenuation …
-
Validation of a Confocal Light Sheet Microscope using Push Broom Translation for Biomedical Applications
… the deep chamber of the R-MHD device, an epitaxial light sheet confocal microscope (e-LSCM) was used to improve axial resolution. The linear sensor, having small pixels, blocked out-of-plane light while eliminating the need for a mechanical aperture which is used for traditional point-scanning …
-
Extended Focus Range High Resolution Endoscopic Optical Coherence Tomography
… over time to achieve the highest possible resolution, speed of image acquisition, sensitivity, and specificity. In the past decade, advances in optics, fiber, as well as laser technology have enabled the development of noninvasive optical biomedical imaging technology that can also be …
-
Deep structure ultrasound imaging using fundamental and third harmonic coded excitation techniques
… fundamental and third harmonic 1, 3 chirps with resolution enhancement compression (REC) and frequency compounding, increases the axial resolution, lateral resolution, penetration depth and the contrast-to-noise ratio (CNR) for an ultrasonic imaging system. The thickness mode of piezoelectric …
-
Computational miniature mesoscope for large-scale 3D fluorescence imaging
… of 0.8~2.5 mm with a high lateral (7 um) and axial resolution (25 um). The CM2 is a novel fluorescence imaging device that achieves large-scale illumination and single-shot 3D imaging on a compact platform. This expanded imaging capability is enabled by computational imaging that jointly …
-
Design of a Fiber-Bundle Based Multispectral Confocal Endomicroscope for Tissue Visualization During Lung Biopsy Procedures
… bundle probe-based fluorescence systems, the axial resolution is challenging to measure, mainly due to the nature of the direct contact of the fiber bundle with the object and the different wavelengths of fluorescence emission and excitation. Therefore, in this dissertation, we find a method …
-
Mathematical Modeling of the Vaporization of Encapsulated Perfluorocarbon Nanodroplets using Chirp Ultrasound
… tissue microvasculature, resulting in poor resolution between blood and the surrounding tissue. This can be remedied using microbubbles which oscillate under ultrasound stimulation and thus provide an enhanced backscattered signal. Free gas bubbles however have a short half-life in the …
-
Development of Optical Coherence Tomography Tools and Algorithms for Advancement in Basic Science and Clinical Research in Otology
… in otology due to its ability to provide high-resolution cross-sectional images and noninvasively measure vibrations and blood flow within tissues. While current techniques lay a strong foundation for OCT in otology, further advancements could enhance our understanding of cochlear function and …
-
Development of Optical Coherence Tomography Tools and Algorithms for Advancement in Basic Science and Clinical Research in Otology
… in otology due to its ability to provide high-resolution cross-sectional images and noninvasively measure vibrations and blood flow within tissues. While current techniques lay a strong foundation for OCT in otology, further advancements could enhance our understanding of cochlear function and …
-
Development of Optical Coherence Tomography Tools and Algorithms for Advancement in Basic Science and Clinical Research in Otology
… in otology due to its ability to provide high-resolution cross-sectional images and noninvasively measure vibrations and blood flow within tissues. While current techniques lay a strong foundation for OCT in otology, further advancements could enhance our understanding of cochlear function and …
-
Development of Optical Coherence Tomography Tools and Algorithms for Advancement in Basic Science and Clinical Research in Otology
… in otology due to its ability to provide high-resolution cross-sectional images and noninvasively measure vibrations and blood flow within tissues. While current techniques lay a strong foundation for OCT in otology, further advancements could enhance our understanding of cochlear function and …
-
Powell Lens-based Line-Scan Spectral Domain Optical Coherence Tomography for Cellular Resolution Imaging of Biological Tissues
… use of cylindrical lenses. It achieves a lateral resolution of <2.1 microns and ~4.1 microns in the x and y directions and an axial resolution of ~1.5 microns in tissue.
-
Submicron-resolution Photoacoustic Microscopy of Endogenous Light-absorbing Biomolecules
… modalities of photoacoustic imaging, optical-resolution photoacoustic microscopy (OR-PAM) can achieve high spatial resolution, on the order of optical wavelength, at <1 mm depth in biological tissue (the optical ballistic regime). OR-PAM has been applied successfully to structural and …
-
Improving ultrasound display by retrieving high-frequency sonographic information
… at a certain depth in tissue is denoted as the axial resolution of the system, which is an important factor in image quality. The axial resolution of ultrasonic B-mode images has been studied by Wagner et al. (1983) and shown to be on the order of the pulse bandwidth. However, a broad pulse …
-
Spinning disk structured illumination microscopy
Among various super-resolution techniques, structured illumination microscopy (SIM) is the most suitable method for live-cell imaging owing to its high speed and low phototoxicity. However, the adoption of SIM faces challenges because of its technical limitations, such as reconstruction artifacts, …
-
A Tunable Extended Depth of Focus Microscope Through Beam Shape Modulation into an Axicon Lens
… of the focal plane while providing high resolution depth profiles, or Axial scans (A-scans), comparable to Optical Coherence Tomography (OCT). Although OCT imaging systems can capture large depth A-scans to buildup high-resolution volumetric images, the information detected by these …
-
Investigation of a Bio-Inspired Range finding Algorithm (BIRA) for ultrasonic imaging systems
… the target structure. It is used to quantify the axial resolution achieved by the BIRA. In a realistic environment, the BIRA appears to be limited in achieving the resolution of the bats. The results presented in the thesis indicate that the techniques inspired from the bat auditory system, as …
-
Improved image speckle noise reduction and novel dispersion cancellation in Optical Coherence Tomography
… and for dispersion compensation to improve axial resolution and image contrast. To address the need for fast data acquisition, a novel, high speed (47,000 A-scans/s), ultrahigh axial resolution (3.3μm) Fourier Domain Optical Coherence Tomography (FD-OCT) system in the 1060nm wavelength …
Page 1 of 9