Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 5 of 5 for “"baffling factor"”.

  1. Effects of inlet/outlet locations and influent temperature on hydraulic disinfection efficiency in contact tanks

    … curves obtained from the CFD simulations and the baffling factor (BF). The physical tank that was used for all tracer tests is located at the Hydraulics Lab at Colorado State University's Engineering Research Center (ERC) in Fort Collins. The rectangular concrete tank was initially constructed …

    colostate Repository record for Effects of inlet/outlet locations and influent temperature on hydraulic disinfection efficiency in contact tanks (opens in a new tab)

  2. Use of innovative techniques to optimize the residence time distribution of drinking water contact tanks

    … distribution (RTD) curves and the well-known baffling factor (BF) (as defined by the USEPA). The principal system that was investigated was a 1500 gallon rectangular concrete tank with a sharp circular inlet. A physical prototype of this system currently resides at Colorado State University's …

    colostate Repository record for Use of innovative techniques to optimize the residence time distribution of drinking water contact tanks (opens in a new tab)

  3. Assessment and improvement of hydraulic disinfection efficiency of a live small drinking water system in South Africa

    … drinking water systems. From this research, the Baffling Factor Guidance Manual (2014) was published, which presents innovative modifications proven to increase the hydraulic disinfection efficiency of small-scale contact tanks. The proposed innovative technology has the potential to have a …

    colostate Repository record for Assessment and improvement of hydraulic disinfection efficiency of a live small drinking water system in South Africa (opens in a new tab)

  4. Impact of geometric design of hydraulic contact tanks on residence time distributions

    … of residence time distributions from which the baffling factor (BF) and Morrill index (MI) performance indicators can be calculated. First, a parametric study of a 300 gallon tank used for previous research was undertaken. After model validation, 30 CFD simulations were conducted in order to …

    colostate Repository record for Impact of geometric design of hydraulic contact tanks on residence time distributions (opens in a new tab)

  5. The innovative application of random packing material to enhance the hydraulic disinfection efficiency of small scale water systems

    … efficiency of a contact basin in terms of baffling factor (BF) there was a lack of fundamental understanding of why RPM is so effective. Conceptually, the RPM slows and spreads the jet flow from a sharp inlet. Yet the mechanics of a jet flow through a highly porous material such as RPM is …

    colostate Repository record for The innovative application of random packing material to enhance the hydraulic disinfection efficiency of small scale water systems (opens in a new tab)