Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 32 for “"bead-based immunoassay"”

  1. Advancement of an agarose bead-based immunoassay platform towards point-of-care applications

    … at the point-of-care which utilizes agarose beads as a solid-support surface for immunoassay testing in a lab-on-a-chip format. This dissertation work describes research directed towards advancing the p-BNC platform. It begins by introducing a new custom-designed flow-through biochip which …

    rice Repository record for Advancement of an agarose bead-based immunoassay platform towards point-of-care applications (opens in a new tab)

  2. Spectroelectrochemical Sensor for Metal Speciation and Bead-Based Immunoassay for Bacillus Anthracis Spores in Finished Water

    … part of the work presents the development of a bead-based enzyme immunoassay to detect the bacterial spores, <i>Bacillus anthracis</i> Sterne strain (<i>Ba</i>). The immunoassay was built by linking biotinylated goat anti <i>Ba</i> antibody to streptavidin coated magnetic beads. Next, …

    ohiolink Repository record for Spectroelectrochemical Sensor for Metal Speciation and Bead-Based Immunoassay for Bacillus Anthracis Spores in Finished Water (opens in a new tab)

  3. A DISPOSABLE POLYMER LAB-ON-A-CHIP WITH MICRO/NANO BIOSENSOR FOR MAGNETIC NANO BEAD-BASED IMMUNOASSAY

    … fabricated, and characterized for magnetic bead-based immunoassay, and applied to the detection of prostate cancer specific antigen as clinical application. A new electroplated permalloy micro array type magnetic bead separator, and an IDA microelectrode electrochemical sensor on polymer …

    ohiolink Repository record for A DISPOSABLE POLYMER LAB-ON-A-CHIP WITH MICRO/NANO BIOSENSOR FOR MAGNETIC NANO BEAD-BASED IMMUNOASSAY (opens in a new tab)

  4. Validation of a Cytometric Bead-based Immunoassay for Tear Interleukin 8 and Interferon Gamma Inducible Protein 10

    … IL-8 and IP-10 measured by multiplexed antibody-based assay are artifact prone and therefore unreliable, leading to their under-utilization as ocular surface disease and dry eye biomarkers. The current study compares tear levels of IL-8 and IP-10 measured by multiplexed cytometric bead-based …

    uab Repository record for Validation of a Cytometric Bead-based Immunoassay for Tear Interleukin 8 and Interferon Gamma Inducible Protein 10 (opens in a new tab)

  5. Preparation, Surface Modification and Application of Lanthanide Nanoparticles as Elemental Tags in Mass Cytometric Bioassays

    … metals. Previous studies established polymer-based lanthanide tags for mass cytometric bioassays. My studies focused on developing a new generation of elemental tags based on Ln NPs for bioassays by mass cytometry. The first part of my thesis describes a ligand exchange strategy for making Ln …

    toronto-retro Repository record for Preparation, Surface Modification and Application of Lanthanide Nanoparticles as Elemental Tags in Mass Cytometric Bioassays (opens in a new tab)

  6. Development of electrochemical antibody-based and enzymatic assays for mycotoxin analysis in food

    … and applied for a competitive magnetic bead-based immunoassay for the mycotoxin ochratoxin A. A limit of detection of 150 pM (60 ng/L) could be obtained and the results were verified with optical detection. The applicability of the magnetic bead-based immunoassay was tested in spiked …

    potsdam-diss Repository record for Development of electrochemical antibody-based and enzymatic assays for mycotoxin analysis in food (opens in a new tab)

  7. Electrochemiluminescence: insights into the mechanisms and nanomaterial-based applications

    … its most promising bioanalytical approaches, the bead-based immunoassay. Nanosystems, such as [Ru(bpy)3]2+-dye-doped nanoparticles (DDSNPs) and Bodipy Carbon Nanodots, have been used to improve the sensitivity of ECL techniques thanks to their advantageous and tuneable properties, reaching a …

    bologna Repository record for Electrochemiluminescence: insights into the mechanisms and nanomaterial-based applications (opens in a new tab)

  8. Patterns in Cytokine Alterations in Inflammatory Bowel Disease Patients are Suggestive of Underlying Disease Activity

    … profiles were investigated using a 17-plex bead-based immunoassay (n = 23). Clinical data was collected by chart review. Localized tissue expression of a target cytokine identified from analysis of the 17-plex cytokine bead-based immunoassay was investigated using immunohistochemistry (IHC) …

    queens Repository record for Patterns in Cytokine Alterations in Inflammatory Bowel Disease Patients are Suggestive of Underlying Disease Activity (opens in a new tab)

  9. The Development of an In Vivo Microdialysis Collection Method of Cytokines from Brain Tissue

    … brain tissue are presented. The first method was based on stopped flow and results indicating that no significant difference in relative recovery between stopped flow and continuous flow are shown. The second method is an antibody bead-based enhancement method. With the antibody bead-based method, …

    arkansas Repository record for The Development of an In Vivo Microdialysis Collection Method of Cytokines from Brain Tissue (opens in a new tab)

  10. Harnessing Acoustic Streaming for Bioanalysis in Microfluidics

    … method has expanded from conventional polymer-based micro devices to 3D-printed micro devices, and allows multiple functions such as electric, optic, magnetic and acoustic to be integrated on a single platform. This dissertation focuses on method development of acoustic streaming-based …

    wvu Repository record for Harnessing Acoustic Streaming for Bioanalysis in Microfluidics (opens in a new tab)

  11. Integrating Continuous and Digital Microfluidics in Electrowetting-on-dielectrics (EWOD) for Heterogeneous Immunoassay

    … integrated in a single device for a human IL-6 immunoassay. Precise volume metering for the immunoassay is achieved via an open-loop electrode-based approach without additional hardware, and volume error is decreased by up to 15% as compared with the conventional cylindrical volume estimation. …

    ohiolink Repository record for Integrating Continuous and Digital Microfluidics in Electrowetting-on-dielectrics (EWOD) for Heterogeneous Immunoassay (opens in a new tab)

  12. MAGNETIC PARTICLE SEPARATORS AND INTEGRATED BIOFILTERS FOR MAGNETIC BEAD-BASED BIOCHEMICAL DETECTION SYSTEM

    … characterized for an integrated magnetic bead-based biochemical detection system. Physical behavior of magnetic particles has been investigated to develop a dynamic monitoring method of magnetic bead separation. In addition, magnetic separation force on the magnetic beads has been …

    ohiolink Repository record for MAGNETIC PARTICLE SEPARATORS AND INTEGRATED BIOFILTERS FOR MAGNETIC BEAD-BASED BIOCHEMICAL DETECTION SYSTEM (opens in a new tab)

  13. Development of techniques and materials for microfluidic devices

    … Fluorescence (LIF) detection for portable bead-based immunoassay and was done using two different approaches. In the first approach the reaction product was detected at the reaction end-point. The detection was evaluated using the dye fluorescein as a model fluorophore in …

    ohiolink Repository record for Development of techniques and materials for microfluidic devices (opens in a new tab)

  14. APPLICATIONS OF MICROBEAD-BASED ELECTROCHEMICAL IMMUNOASSAY

    … research was to develop an enzyme-labeled microbead-based electrochemical immunoassay towards detection of viral biothreat agents in drinking water using an automated microfluidic device. Previous group members developed a bead-based immunoassay for a model analyte under optimal laboratory …

    ohiolink Repository record for APPLICATIONS OF MICROBEAD-BASED ELECTROCHEMICAL IMMUNOASSAY (opens in a new tab)

  15. Milk Fat Globule-Epidermal Growth Factor-Factor 8 (MFG-E8) as a Novel Biomarker for Periodontal Disease

    … MFG-E8 and cytokines using multiplexing magnetic bead immunoassays (Luminex xMAP with MagPlex beads). Each sample was tested using an MFG- E8 kit, a human cytokine/chemokine kit and a human bone panel kit. RESULTS: MFG-E8 was detected at higher levels in sites with gingivitis and gingival health …

    penn Repository record for Milk Fat Globule-Epidermal Growth Factor-Factor 8 (MFG-E8) as a Novel Biomarker for Periodontal Disease (opens in a new tab)

  16. Role of Macrophages in Ocular Surface Fibrosis

    … macrophages was analyzed using real-time PCR and bead-based immunoassay. Our data demonstrates successful generation of M0 macrophages and their polarization into M1 and M2 phenotypes as confirmed by gene quantification and flow cytometry for macrophage markers CD11b, F4/80, CD86, CD206, iNOS, and …

    chapman Repository record for Role of Macrophages in Ocular Surface Fibrosis (opens in a new tab)

  17. High Avidity Antibodies to VAR2CSA: Are They Associated with Protection from Placental Malaria in a Low Transmission Setting?

    … for IgG Ab to Full Length VAR2CSA (FV2) using a bead-based immunoassay and 494 samples were identified as being Ab-positive. The percentage of strong binding (high avidity) IgG equals the amount of Ab that remain bound to FV2 after 30 minutes of incubation with 3M NH4SCN. Results showed that 178 …

    hawaii Repository record for High Avidity Antibodies to VAR2CSA: Are They Associated with Protection from Placental Malaria in a Low Transmission Setting? (opens in a new tab)

  18. ASSESSING VACCINE EFFICACY AND SEROPREVALENCE USING MULTIPLEX IMMUNOASSAYS: DEVELOPMENT, VALIDATION, AND APPLICATIONS IN DIVERSE POPULATIONS

    … validation, and performance of a Multiplex Bead-Based Immunoassay (MIA) as a tool to assess vaccine efficacy and seroprevalence. The study's multifaceted approach encompasses three key objectives: optimization of the MIA using SARS-CoV-2 Spike subunits produced in Drosophila S2 insect cell …

    hawaii Repository record for ASSESSING VACCINE EFFICACY AND SEROPREVALENCE USING MULTIPLEX IMMUNOASSAYS: DEVELOPMENT, VALIDATION, AND APPLICATIONS IN DIVERSE POPULATIONS (opens in a new tab)

  19. Comparison of Azithromycin and Amoxicillin for Prophylaxis at Dental Implant Placement: A Randomized Pilot Study of Bioavailability and Anti-inflammatory Effects

    … out using a commercially available multiplex bead-based immunoassay. The results showed that at 6 days AZM concentration in serum, GCF and PICF was 0.015±0.002 µg/ml, 3.39±0.73 µg/ml and 2.77±0.90 µg/ml, respectively, whereas in the AMX group antibiotic concentration was below the level of …

    ohiolink Repository record for Comparison of Azithromycin and Amoxicillin for Prophylaxis at Dental Implant Placement: A Randomized Pilot Study of Bioavailability and Anti-inflammatory Effects (opens in a new tab)

  20. DNA Nanostructures for Nanopore-based Digital Assays

    … assays. I conclude by presenting a magnetic bead-based immunoassay scheme using a digital solid-state nanopore readout. Nanopore has the ability to count molecules one at a time, this allows accurate and precise determination of the concentration of a biomarker in solution. Coupled with the …

    ottawa-retro Repository record for DNA Nanostructures for Nanopore-based Digital Assays (opens in a new tab)

Page 1 of 2